The A/C pressure
transducer converts the pressure value of the high pressure line into a
voltage value after measurement. By a converted voltage value the ECU
controls the cooling fan by operating it at high or low speed. The ECU
stops the compressor operation when the temperature of the refrigerant
line is too high or too low. |