Power Door Locks › Power Door Lock Relay: Repair procedures
INSPECTION
DOOR
LOCK
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the ICM relay
box.
3.
Check for continuity between the
terminals.
4.
There should be continuity between the No.5
terminal and No.14 terminals in the ICM-B when power and ground are
connected to the No.11 terminal and No.13 terminal in the
ICM-B.
5.
There should be no continuity between the
No.5 terminal and No.14 terminal in the I/P-D when power is
disconnected.
DOOR
UNLOCK
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the ICM relay
box.
3.
Check for continuity between the
terminals.
4.
There should be continuity between the No.4
terminal and No.14 terminal in the ICM-B when power and ground are
connected to the No.10 terminal and No.13 terminal in the
ICM-B.
5.
There should be no continuity between the
No.4 terminal and No.14 terminal in the ICM-B when power is
disconnected.
TRUNK
LID OPEN
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the passenger compartment junction
box.
3.
Check for continuity between the
terminals.
4.
There should be continuity between the No.3
terminal in the I/P-H and the No.2 terminal in the I/P-D when power
and ground are connected to the No.3 terminal in the I/P-H and the
No.28 terminal in the I/P-F.
5.
There should be no continuity between the
No.3 terminal in the I/P-H and the No.2 terminal in the I/P-D when
power and ground are connected to the No.3 terminal in the I/P-H and
the No.28 terminal in the I/P-F.