Lighting System › Hazard Lamp Switch: Repair procedures
INSPECTION
HAZARD
LAMP SWITCH
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the crash pad center facia panel
(A).
(Refer to the Body group - Crash
pad)
3.
Disconnect the hazard lamp switch
conector.
4.
Operate the switch and check for continuity
between terminals with an ohmmeter.
HAZARD
LAMP RELAY
1.
Disconnect the negative (-) battery
terminal.
2.
Disconnect the ICM relay box
connector.
3.
Check for continuity between terminals.
There should be continuity between the No.3 and No.12 or No.7 of
ICM-B terminals when power and ground are connected to the No.3 and
No.17 of ICM-B terminals.
4.
There should be no continuity between the
No.3 and No.12 or No.7 of ICM-B terminals when power is disconnected
to the No.3 and No.17 of ICM-B terminals.