When driver inserts
key and IGN "ON", Immobilizer informs status of system and result of
Authentication by blinking of immobilizer lamp on instrument cluster.
through Authentication procedure immobilizer lamp keep lighting up till
engine starts. In normal status. Immobilizer lamp lights up for 30sec
Right after ignition "ON". If there’s any fault in immobilizer system or
in Authentication, lamp blinks 5 times after ignition "ON".
The ECM sets DTC P1692
if there's short circuit in immobilizer lamp circuit.
Item
|
Detecting Condition
|
Possible Cause
|
DTC Strategy
|
|
● Short Circuit in immobilizer lamp
circuit ● Open/Short in control
harness ● Faulty
PCM/ECM
|
Enable Conditions
|
● IG ON
|
Threshold value
|
● Short to GND, Wiring open
|
Detecting time
|
|
FAIL SAFE
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system
are caused by poor harness and terminals.
Faults can also be caused by interference
from other electrical systems, and mechanical aor chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to
"Verification Vehicle Repair" procedure.

▶ Go to "W/Harness Inspection"
procedure. |
| Contol Circuit
Inspection |
Check
for open in harness
| 2. |
Connect SMARTRA connector and disconnect PCM
connector |
| 3. |
IG KEY ON & Engine
"OFF" |
| 4. |
Measure voltage between indicator terminal
of PCM harness connector and chassis ground.
|
| 5. |
Is the measured voltage within
specifications

▶ Go to "Component Inspection"
procedure

▶ Check for open or short in harness. Repair
as necessary and go to "Verification of Vehicle Repair"
procedure. |
| Visual / Physical
Inspection |
| 1. |
Check immobilizer lamp circuit
| (1) |
Ignition "ON" & Engine
"OFF" |
| (2) |
Check if immobilizer lamp operates
properly.
|
※ Right after ignition "ON",
Immobilizer lamp lights up for 30sec.
If lamp blinks 5 times after
ignition "ON", there’s any fault in immobilizer
system. | |
| (3) |
Is immobilizer lamp operates
properly?

▶ Check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration,
or damage. Repair or replace as necessary and then go to
"Verification of Vehicle Repair" procedure.

▶ Go to "Component Inspection"
procedure. | |
Check
immobilizer lamp
| 2. |
Connect SMARTRA connector and disconnect PCM
connector |
| 3. |
Ground indicator terminal of PCM harness
connector with wire. |
| 4. |
IG KEY ON & Engine "OFF"
Specification : Immobilizer lamp
"ON"
| |
| 5. |
Is the Immobilizer lamp "ON"?

▶ Substitute with a known-good ECM and check
for proper operation.
If the problem is corrected, replace ECM and
then go to "Verification of Vehicle Repair" procedure.
|
※ ECM substitued for old one must be
in "Virgin" or "Neutral" status and Pin code is requied to
Neutralize ECM and to Register transponder
key |

▶ Check that fuse has blown off and harness
between ECM connector and Battery is in normal condition. And. check
connectors for looseness, poor connection, bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and then go to "Verification of Vehicle Repair"
procedure. |
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and selet "Diagnostic
Trouble Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on
the scantool. |
| 3. |
Are any DTCs present?

▶ Go to the applicable troubleshooting
procedure.

▶ System is performing to specification at
this time. |
| Diagnostic Circuit
Diagram |