| ANTI-THEFT WARNING
SYSTEM |

BURGLAR
ALARM SYSTEM
The burglar alarm
system is armed automatically after the doors, hood, and trunk are closed
and locked.
The system is set off
when any of these things occur :
| •
|
The trunk is opened without using the
key. |
When the system is set
off, the alarm sounds and the hazard lamp flash for about 30 seconds or
until the system is disarmed by unlocking the transmitter.
For the system to arm,
the ignition switch must be off and the key removed. Then, the body
control module must receive signals that the doors, hood, and trunk are
closed and locked. When everything is closed and locked, none of the
control unit inputs are grounded.
The door switches,
hood switch and trunk switch are all close and lock the doors with the
remote transmitter and then the system arms immediately.
If anything is opened
after the system is armed, the body control module gets a ground signal
from that switch, and the system is set off.
If one of the switches
is misadjusted or there is a short in the system, the system will not arm.
As long as the body control module continues to get a ground signal, it
thinks the vehicle is not closed and locked and will not arm.
KEYLESS
ENTRY SYSTEM
The burglar alarm
system is integrated with the keyless entry system. The keyless entry
system allows you to lock and unlock the vehicle with the remote
transmitter. When you push the LOCK/UNLOCK button, all doors lock. When
you push the LOCK/UNLOCK button again, all doors unlock.
The room lamp, if its
switch is in the center position, will come on when you press the UNLOCK
button. If you do not open a door, the light will go off in about 30
seconds, the doors will automatically relock, and the burglar alarm system
will rearm. If you relock the doors with the remote transmitter within 30
seconds, the light will go off immediately.
You cannot lock or
unlock the doors with the remote transmitter if the key is in the ignition
switch.
The system will signal
you when the doors lock and unlock by flashing the hazard lamp once when
they lock, and twice when they unlock.
KEYLESS
ENTRY FUNCTION
DOOR LOCK / UNLOCK,
TRUNK and panic operation are performed with remocon
| 1. |
Keyless entry function is performed in a
state that key in SW is eliminated from key
cylinder |
| 2. |
LOCK / UNLOCK, TRUNK and panic signals are
received from the transmitter and DOOR LOCK / UNLOCK, TRUNK and
panic signals are output. |
TRANSMITTER(TX)
SPEC
| 1. |
Transmission Distance : 30m or more from
outside of the car |
| 2. |
Registration procedure of the
transmitter
| (1) |
In registration mode, it shall be
possible to register up to Max
4EA. |
| (2) |
At re-registration, data are
registered newly after deleting the previous TX
DATA
No.
|
Saved CODE
|
CODE to change
|
Changed CODE
|
1
|
-
|
A
|
A
|
2
|
A
|
B
|
B (A is deleted)
|
3
|
B
|
C, D
|
C, D (B is deleted)
|
4
|
C, D
|
E, F, G
|
E, F, G (C, D is deleted)
|
5
|
E, F, G
|
H, I, J, K
|
H, I, J, K (E, F, G are
deleted)
|
6
|
A, B
|
C, F, E, F, G
|
C, F, E, F
|
7
|
A, B
|
C, C, D, E, F
|
C, F, E,
|
8
|
A, B, C, D
|
A
|
A
|
9
|
A, B, C, D
|
E
|
E
|
|
| (3) |
For the registration procedures by
using Hi-scan tool, refer to "TRANSMITTER CODE
REGISTRATION". | |
| 3. |
Transmitter signal & Receiver
Spec
| (1) |
Transmission signal
| A. |
Transmit relevant transmission
DATA (Transmission frame) twice by pushing TX
SW. |
| B. |
Only LOCK signal is output when
pushing TX LOCK SW and UNLOCK SW at the same
time. | | |
DISARM
Condition 1
State
|
Description
|
Initial Condition
|
ALARM state
|
Event
|
| •
|
IGN KEY ON during 30sec or ALT"L" =
ON |
| •
|
TX(Transmitter) Unlock & Any Door
open(4Door SW ON) |
| •
|
TX(Transmitter) Lock & Lock
confirm failed |
| •
|
Driver door key unlock switch
ON. |
| •
|
Driver door key lock SW ON & Lock
confirm failed | |
Action
|
| •
|
The state goes to DISARM
state |
| •
|
Hazard relay off, Horn relay off and
start inhibit relay off. |
| - |
Unlock relay on for 0.5
sec. |
| - |
Hazard relay on
(TWICE) | | |



Condition 2
State
|
Description
|
Initial Condition
|
DISARM state & (IGN KEY OUT) & Any Door
open
|
Event
|
|
Action
|
| - |
Unlock relay on for 0.5
sec |
| - |
Hazard relay on
(Twice) | | |
Condition 3
State
|
Description
|
Initial Condition
|
ARMWAIT state
|
Event
|
| •
|
At least one entrance
opened |
| •
|
Driver door key unlock SW
ON | |
Action
|
The state goes to DISARM
state
|
Condition 4
State
|
Description
|
Initial Condition
|
AUTOLOCKTIMER1 state
|
Event
|
| •
|
At least one entrance
opened |
| •
|
Lock by AUTOLOCK, but Lock
confirmation failure |
| •
|
Tx Lock, but Lock confirmation
failure |
| •
|
Driver door key unlock SW ON, but Lock
confirmation failure | |
Action
|
| •
|
The state goes to DISARM
state | |
Condition 5
State
|
Description
|
Initial Condition
|
AUTOLOCKTIMER2 state
|
Event
|
| •
|
Hood Open & Memory Hood was
Close |
| •
|
Trunk Open & Memory Trunk was
Close |
| •
|
Lock by AUTOLOCK, but Lock
confirmation failure |
| •
|
Tx Lock, but Lock confirmation
failure |
| •
|
Driver door key unlock SW ON, but Lock
confirmation failure | |
Action
|
| •
|
The state goes to DISARM
state | |
Condition 6
State
|
Description
|
Initial Condition
|
ARM state or ARM HOLD state
|
Event
|
| •
|
Driver door key unlock SW
ON | |
Action
|
| •
|
The state goes to DISARM
state | |
Condition 7
State
|
Description
|
Initial Condition
|
REARM state
|
Event
|
| •
|
IGN KEY ON during 30sec or ALT"L" =
ON |
| •
|
Tx Lock, but Lock confirmation
failure |
| •
|
Driver door key unlock SW
ON |
| •
|
Driver door key unlock SW ON &
Lock confirmation
failure | |
Action
|
| •
|
The state goes to DISARM
state |
| •
|
Start Inhibit relay
OFF | |
Condition 8
State
|
Description
|
Initial Condition
|
PREARM state
|
Event
|
| •
|
All entrance closed & Any Door is
unlocked |
| •
|
Any Door open & Tx
Unlock | |
Action
|
| •
|
The state goes to DISARM
state |
| - |
Unlock relay on for
0.5sec |
| - |
Hazard relay on
(Twice) | | |
ARM
Condition 1
State
|
Description
|
Initial Condition
|
ARM state
|
Event
|
|
Action
|
| •
|
Hazard relay 1Time
on(1sec) | |
Condition 2
State
|
Description
|
Initial Condition
|
ARMHOLD state
|
Event
|
| •
|
Trunk closed for at least Trunk
Release Time Out(default
30s) | |
Action
|
| •
|
The state goes to ARM
state | |
Condition 3
State
|
Description
|
Initial Condition
|
ARMWAIT state
|
Event
|
| •
|
ARMWAITTIMER is
expired | |
Action
|
| •
|
The state goes to ARM
state | |
ALARM
Condition 1
State
|
Description
|
Initial Condition
|
ARM state
|
Event
|
| •
|
Any entrance open (DOORS, TRUNK, or
HOOD) | |
Action
|
| •
|
The state goes to ALARM
state |
| •
|
The horn rings 3 times with
27sec(±2sec) on
10sec(±2sec)off |
| •
|
The hazard is driven also (During Horn
driving) |
| •
|
Engine Start Inhibit is
ON | |

T1 : 27s (±2sec), T2 :
10s (±2sec),
T3 : 0.5s ± 0.1
sec.
|
Horn Output : Period : 1sec(Can be
calibrated Horn Period), 50% Duty |
Condition 2
State
|
Description
|
Initial Condition
|
ARMHOLD state
|
Event
|
| •
|
Any door open or Hood
open |
|
Action
|
| •
|
The state goes to ALARM
state |
| •
|
The horn rings 3 times with
27sec(±2sec) on 10sec(±2sec)
off |
| •
|
The hazard is driven also (During Horn
driving) |
| •
|
Engine Start Inhibit is
ON | |
Condition 3
State
|
Description
|
Initial Condition
|
REARM state
|
Event
|
| •
|
Any door open or Hood open or Trunk
open | |
Action
|
| •
|
The state goes to ALARM
state |
| •
|
The horn rings 3 times with
27sec(±2sec) on 10sec(±2sec)
off | |

ARM
WAIT MODE
Condition 1
State
|
Description
|
Initial Condition
|
ARMWAIT state
|
Event
|
|
Action
|
| •
|
The state goes to
State |
| - |
Hazard relay 1 Time
on(1sec) | | |
Condition 2
State
|
Description
|
Initial Condition
|
DISARM state & IGN KEY OUT & All entrances
closed (DOORS, HOOD and TRUNK)
|
Event
|
| •
|
Tx Lock & locked
confirmed |
| •
|
Driver door key lock SW ON &
Locked confirmed |
| •
|
All doors locked & All doors
closed (All doors not closed
1→0) | |
Action
|
| •
|
The state goes to ARMWAIT
State |
| •
|
Hazard relay 1Time
on(1sec) | |
Condition 3
State
|
Description
|
Initial Condition
|
ALARM state & All entrances closed(DOORS, HOOD and
TRUNK)
|
Event
|
| •
|
Tx Lock & locked
confirmed |
| •
|
Driver door key lock SW ON &
Locked confirmed | |
Action
|
| •
|
The state goes to ARMWAIT
state |
| •
|
Start inhibit relay
off |
| •
|
Hazard relay 1Time
on(1sec) | |
Condition 4
State
|
Description
|
Initial Condition
|
AUTOLOCKTIMER1 state
|
Event
|
| •
|
Tx Lock & locked
confirmed |
| •
|
Driver door key lock SW ON &
Locked confirmed | |
Action
|
| •
|
The state goes to ARMWAIT
state |
| •
|
Hazard relay 1Time
on(1sec) | |
Condition 5
State
|
Description
|
Initial Condition
|
PREARM state
|
Event
|
| •
|
Hood and 4door are closed & All
doors locked & (Trunk closed & Trunk default value is
clear) | |
Action
|
| •
|
The state goes to ARMWAIT
state |
| •
|
Hazard relay 1Time
on(1sec) | |
Condition 6
State
|
Description
|
Initial Condition
|
REARM state
|
Event
|
| •
|
Tx Lock & locked
confirmed |
| •
|
Drive door key lock SW ON & locked
confirmed | |
Action
|
| •
|
The state goes to ARMWAIT
state |
| •
|
Start inhibit relay
off |
| •
|
Hazard relay 1Time
on(1sec) | |

REARM
MODE
Condition 1
State
|
Description
|
Initial Condition
|
ALARM state
|
Event
|
| •
|
All entrance is closed & Alarm
Patten finished | |
Action
|
| •
|
The state goes to REARM
state | |
AUTOLOCKTIMER1
MODE
Condition 1
State
|
Description
|
Initial Condition
|
ARM state
|
Event
|
|
Action
|
| •
|
The state goes to AUTOLOCKTIMER1
state |
| •
|
Hazard relay Twice on(0.5s ON/0.5s
OFF) | |
Condition 2
State
|
Description
|
Initial Condition
|
AUTOLOCKTIMER1 state
|
Event
|
|
Action
|
| •
|
The state goes to
State |
| - |
Hazard relay Twice on(0.5s
ON/0.5s OFF) |
|
|
Condition 3
State
|
Description
|
Initial Condition
|
ARMWAIT state
|
Event
|
|
Action
|
| •
|
The state goes to AUTOLOCKTIMER1
state |
| •
|
Hazard relay Twice on(0.5s ON/0.5s
OFF) | |
Condition 4
State
|
Description
|
Initial Condition
|
DISARM state & All entrances closed (DOORS, HOOD
& TRUNK) & IGN KEY OUT
|
Event
|
|
Action
|
| •
|
The state goes to AUTOLOCKTIMER1
state |
| •
|
Hazard relay Twice on(0.5s ON/0.5s
OFF) | |
Condition 5
State
|
Description
|
Initial Condition
|
ALARM state & All entrances are closed (DOORS, HOOD
& TRUNK)
|
Event
|
|
Action
|
| •
|
The state goes to AUTOLOCKTIMER1
state |
| •
|
Hazard relay Twice on(0.5s ON/0.5s
OFF) |
| •
|
Start inhibit relay
off |
|
Condition 6
State
|
Description
|
Initial Condition
|
REARM state
|
Event
|
|
Action
|
| •
|
The state goes to AUTOLOCKTIMER1
state |
| •
|
Hazard relay Twice on(0.5s ON/0.5s
OFF) |
| •
|
Start inhibit relay
off | |
AUTOLOCKTIMER2
MODE
Condition 1
State
|
Description
|
Initial Condition
|
ARMHOLD state
|
Event
|
|
Action
|
| •
|
The state goes to AUTOLOCKTIMER2
state |
| •
|
Memorize Hood and Trunk
state |
| •
|
Hazard relay Twice on(0.5s ON/0.5s
OFF) | |
Condition 2
State
|
Description
|
Initial Condition
|
AUTOLOCKTIMER2 state
|
Event
|
|
Action
|
| - |
Hazard relay Twice on(0.5s
ON/0.5s OFF) |
|
|
Condition 3
State
|
Description
|
Initial Condition
|
DISARM state & All Doors are closed & (HOOD or
TRUNK is opened) & IGN KEY OUT
|
Event
|
|
Action
|
| •
|
The state goes to AUTOLOCKTIMER2
state |
| •
|
Memorize Hood and Trunk
state |
| •
|
Hazard relay Twice on(0.5s ON/0.5s
OFF) | |
Condition 4
State
|
Description
|
Initial Condition
|
ALARM state & All Door are closed & (HOOD or
TRUNK is opened)
|
Event
|
|
Action
|
| •
|
The state goes to AUTOLOCKTIMER2
state |
| •
|
Memorize Hood and Trunk
state |
| •
|
Hazard relay Twice on(0.5s ON/0.5s
OFF) |
| •
|
Start inhibit relay
off |
|
Condition 5
State
|
Description
|
Initial Condition
|
PREARM state All Doors are
closed & (HOOD or TRUNK is opened)
|
Event
|
|
Action
|
| •
|
The state goes to AUTOLOCKTIMER2
state |
| •
|
Memorize Hood and Trunk
state |
| •
|
Hazard relay Twice on(0.5s ON/0.5s
OFF) | |
PREARM
MODE
Condition 1
State
|
Description
|
Initial Condition
|
ARMHOLD state
|
Event
|
| •
|
Driver door key lock SW
ON | |
Action
|
| •
|
The state goes to PREARM
state | |
Condition 2
State
|
Description
|
Initial Condition
|
AUTOLOCKTIMER2 state
|
Event
|
| •
|
Tx Lock & locked
confirmed |
| •
|
Driver door key lock SW ON &
Locked confirmed | |
Action
|
| •
|
The state goes to PREARM
state | |
Condition 3
State
|
Description
|
Initial Condition
|
ARMWAIT state
|
Event
|
| •
|
Trunk key unlock SW
ON. | |
Action
|
| •
|
The state goes to PREARM
state |
| •
|
Start TRUNKTIMER (Trunk release time
out (default 30sec.)) |
| •
|
Trunk default value is
clear | |
Condition 4
State
|
Description
|
Initial Condition
|
DISARM state & IGN KEY OUT
|
Event
|
| •
|
((4Door Not Closed = ON) or (Trunk
Open SW = ON) or (Hood SW = ON)) & Tx Lock & Locked
confirmed |
| •
|
((4Door Not Closed = ON) or (Trunk
Open SW = ON) or (Hood SW = ON)) & driver door key lock SW
ON on & Locked confirmed |
| •
|
(4Door Locked) & (4Door not closed
ON→OFF) & (Hood SW = ON or Trunk Open SW =
ON) | |
Action
|
| •
|
The state goes to PREARM
state | |
Condition 5
State
|
Description
|
Initial Condition
|
ALARM state & At least one entrance
opened
|
Event
|
| •
|
Tx Lock & Locked
confirmed |
| •
|
Driver door key lock SW ON &
Locked confirmed | |
Action
|
| •
|
The state goes to PREARM
state |
| •
|
Start inhibit relay
off |
| •
|
Hazard relay 1Time on
(1sec.) | |
Condition 6
State
|
Description
|
Initial Condition
|
PREARM
|
Event
|
| •
|
Trunk Opened or TRUNKTIMER
expired | |
Action
|
| •
|
Trunk default value is
clear |
| •
|
Stop TRUNKTIMER except at TRUNKTIMER
expired | |
ARMHOLD
MODE
Condition 1
State
|
Description
|
Initial Condition
|
ARM state
|
Event
|
|
Action
|
| •
|
The state goes to ARM HOLD
state |
| •
|
The alarm for the trunk is only
suspended, but the alarm for doors and hood keeps on
arming | |

RESET
| 1. |
In case of taking the battery out during the
ALARM state
Condition
State
|
Description
|
Initial Condition
|
During ALARM, REARM
|
Event
|
| • |
TAKING THE BATTERY OUT (Cold or
Warm RESET) | |
Action
|
| • |
The state goes to ALARM
mode |
| • |
Horn relay 3 Times on (No
remained time of warning
signal) |
| • |
Hazard lamp is flashing during
making
horn | |

|
| 2. |
In case of taking the battery out during
arm
Condition
State
|
Description
|
Initial Condition
|
ARM state
|
Event
|
| • |
TAKING THE BATTERY OUT (Cold or
Warm RESET) | |
Action
|
| • |
The state goes to ALARM
mode |
|

|
| 3. |
In case of taking the battery out during the
ARMHOLD state
Condition
State
|
Description
|
Initial Condition
|
ARMHOLD state
|
Event
|
| • |
TAKING THE BATTERY OUT (Cold or
Warm RESET) | |
Action
|
| • |
The state goes to ARMHOLD
mode |
| • |
Maintained ARMHOLD
state | |
|
DOOR
UNLOCK AND TRUNK OPEN INHIBITION
| 1. |
UNLOCK signal output with DOOR UNLOCK SW by
power window and TRUNK SW is prohibited in case of TX LOCK under IGN
KEY OFF. |
| 2. |
UNLOCK signal output with DOOR UNLOCK SW by
power window and TRUNK SW is inhibited in case of DOOR LOCK with
DOOR KEY under IGN KEY OFF. |
| 3. |
UNLOCK inhibition function is cancelled in
case of TX UNLOCK while DOOR UNLOCK inhibition function
activates. |
| 4. |
UNLOCK inhibition function by power window
is cancelled in case of DOOR UNLOCK with DOOR KEY while DOOR UNLOCK
inhibition function activates. |
| 5. |
UNLOCK inhibition function is cancelled at
IGN KEY IN & IGN ON.

T1 : 0.5s ±
0.1s |
TRUNK
OPEN BY TX (Transmitter)
| 1. |
TRUNK RELEASE RELAY is turned ON for 0.5s if
TRUNK signal of TX is received.
(Hold MODE under
ARM) |
| 2. |
TRUNK RELEASE RELAY is turned ON for 0.5s in
case of TRUNK RELEASE SW OFF→ON. |
| 3. |
In ARM mode, signal by TRUNK RELEASE SW
input is not output.

T1 : 0.5s ±
0.1s |
PANIC
Alarm
| 1. |
PANIC alarm is turned ON for T1 by using
HORN and HAZARD if TX PANIC signal is
received. |
| 2. |
PANIC alarm is turned OFF if (TX
LOCK/UNLOCK/PANIC/TRUNK UNLOCK /KEY IN /DOOR KEY LOCK/DOOR KEY
UNLOCK / TRUNK KEY UNLOCK ) signals are received during PANIC
alarm. |
| 3. |
PANIC signal output is immediately turned
OFF and the state becomes ARM state if the condition for ARM is met
during PANIC alarm. |
| 4. |
The below is about antitheft
alarm.
| (1) |
Antitheft alarm does not stop even
when PANIC signal of TX is received during the alarm. (PANIC
signal reception is ignored) |
| (2) |
Antitheft alarm signal is output when
the condition for antitheft is met during PANIC alarm. (PANIC
signal output: OFF) |
| (3) |
PANIC alarm is turned ON with
continuing antitheft function when PANIC signal is received in
ARM stand-by / ARM / Alarm end / RELOCK stand-by
mode. |
* Even when Other TX signals, registered
during PANIC alarm, are received, they are regarded as the same
TX

T1 : 30s±3s (0.9s cycle
DUTY50%) |
HORN
ANSWER BACK
| 1. |
Under DOOR, TRUNK or HOOD: Closed, HORN(T2
output), HAZARD(1s-output) signals are output if TX LOCK signal is
received again within T1 from the moment when the mode transits to
ARM mode by TX LOCK operation and ARM mode is
kept. |
| 2. |
HORN and HAZARD signals are not output if
ARM mode is cancelled for T1. |
| 3. |
HORN and HAZARD signal are output even when
other LOCK signals of TX, registered during T1, are
received.
* DOOR LOCK signal and HAZARD signal are not
displayed. (refer to the antitheft function)

T1 : 4s within
T2 : 0.05s ±
0.01s |