Heated Oxygen Sensor
(HO2S) consists of zirconium and alumina and is installed on upstream and
downstream of the Manifold Catalyst Converter (MCC). After it compares
oxygen consistency of the atmosphere with the exhaust gas, it transfers
the oxygen consistency of the exhaust gas to the ECM. In order that this
sensor normally operates, the temperature of the sensor tip is higher than
370°C (698°F). So it has a heater which is controlled by the ECM duty
signal. When the exhaust gas temperature is lower than the specified
value, the heater warms the sensor tip.
SPECIFICATION
HO2S [Bank 1/Sensor 1]
Item
|
Specification
|
Heater Resistance (Ω)
|
2.4 ~ 2.9Ω at 20°C
(68°F)
|
HO2S [Bank 1/Sensor 2]
A/F Ratio
|
Output Voltage
(V)
|
RICH
|
0.6 ~ 1.0
|
LEAN
|
0.1 ~ 0.4
|
Item
|
Specification
|
Heater Resistance (Ω)
|
Approx. 9.0Ω at 20°C
(68°F)
|

COMPONENT
INSPECTION
| 1. |
Disconnet the HO2S
connector. |
| 2. |
Measure resistance between HO2S heater
terminals 5 and 6 [B1/S1].
Measure resistance between HO2S heater
terminals 3 and 4 [B1/S2]. |
| 3. |
Check that the resistance is within the
specification.
Specification: Refer to
SPECIFICATION.
| |