The linear O2 sensor is
mounted on the front side of the Catalytic Converter (warm-up catalytic
converter) or in the front exhaust pipe. It detects a wide range of
air/fuel ratios in the exhaust gas from the rich to lean regions. This
linear O2 sensor produces a current that corresponds to a specific
air/fuel ratio. The ECM monitors this signal and determines whether the
air/fuel mixture is rich or lean. The ECM constantly monitors the linear
O2 sensor and increases or decreases the fuel injection duration using
this signal. This is called closed-loop fuel control
operation.
The control unit of the
linear oxygen sensor built inside the ECM monitors short circuit error on
all front Heated Oxygen Sensor (HO2S) control lines (PIN#19, PIN#40,
PIN#41 and PIN#53) and ECM sets P0132 with short circuit to battery. If
same code is set again in the next driving cycle, MIL is
illuminated.
Item
|
Detecting
Condition
|
Possible Cause
|
DTC
Strategy
|
|
| •
|
Short to ground in signal
harness |
| •
|
Poor connection or damaged
harness |
| •
|
Faulty Heated O2
Sensor(HO2S) | |
Enable
Conditions
|
| •
|
10V < Battery voltage <
16V | |
Threshold
Value
|
| •
|
Short circuit to
ground | |
Diagnostic
Time
|
|
MIL On
Condition
|
|

| 1. |
Voltage in HO2S
Test Condition : Ignition ON, Engine OFF
/ HO2S disconnected
|
Terminal
|
Connected to
ECM
|
Funtion
|
Normal
Parameter
|
Heater
Resistance
|
1
|
43
|
HO2S
(VN)
|
Approx.2~3V(disconnected)
|
-
|
2
|
46
|
HO2S
(VRC)
|
Approx.2~3V(disconnected)
|
-
|
3
|
45
|
HO2S
(VIP)
|
Approx.2~3V(disconnected)
|
-
|
4
|
44
|
HO2S
(VG)
|
Approx.2~3V(disconnected)
|
-
|
5
|
Main
Relay
|
Heater
Power
|
Bat
(+)
|
-
|
6
|
93
|
Heater
Control
|
Approx.4.5V
|
Heater
Resistance :
2.4~2.9Ω
|
|
| 2. |
Scan Tool Data

Fig.1) Normal HO2S(B1S1) value with engine
warm-up and idling : Approx. 1.5~2.0V
▶Signal decreases with rich air/fuel mixture
and increases with lean air/fuel mixture
▶Fuel cut-off mode : Approx 3.2
V |
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode |
| 2. |
Press F4(DTAL) to select DTC information from
the DTCs menu. |
| 3. |
Confirm that "DTC Readiness Flag" indicates
"Complete". If not, drive the vehicle within conditions noted in the
freeze frame data or enable
conditions |
| 4. |
Read "DTC Status" parameter

|
| 5. |
Is parameter displayed "History(Not Present)
fault"?
|
- History (Not Present) fault : DTC
occurred but has been cleared.
- Present fault : DTC is occurring at
present time. |
|

|
▶ Fault is
intermittent caused by poor contact in the sensor’s and/or the
ECM’s connector or was repaired and ECM memory was not
cleared. Thoroughly check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration,
or damage. Repair or replace as necessary and then go to
"Verification of Vehicle Repair" procedure
|
|

|
▶ Go to
"W/Harness Inspection"
procedure
|
|
| Control Circuit
Inspection |
| 2. |
Disconnect HO2S and ECM
connector |
| 3. |
Ignition "OFF", Engine
"ON" |
| 4. |
Measure resistance between terminal 3 of the
sensor harness connector and chassis ground
Specification
: Approx. 2~3V
|

|
| 5. |
Is HO2S display near the
specification?
|

|
▶ Go to
next step as below
|
|

|
▶ Repair or
replace as necessary and go to "Verification of Vehicle
Repair" procedure
|
HO2S must have a clean air
reference to function properly. The air is obtained by
way of the sensor wire(s). Do not attempt to repair the
wire(s), connector, or the
terminals. | |
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness(es) and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification of Vehicle Repair"
procedure
|
|

|
▶ Go to
next step as
below
|
|
| 1. |
Inspect the front HO2S for any silicon
contamination. This contamination will be indicated by a white
powdery coating and this will result in a but false voltage
signal.
If contamination is evident on the HO2S,
replace contaminated sensor and go to next
step. |
| 2. |
Warm up the engine to normal operating
temperature and check that HO2S signal is
active |
| 3. |
Connect Scantool and monitor the "O2 SNSR
VOLT.(B1/S1)" parameter on the Scantool data list.
Test Condition
: Engine "ON" & In Closed loop
mode
Specification
:
- Normal HO2S(B1S1) value with engine
warm-up and idling : Approx. 1.5~2.0V
- Signal decreases with rich air/fuel
mixture and increases with lean air/fuel mixture
- Voltage at Fuel cut-off mode : Approx.
3.0~4.0V
| |
| 4. |
Is sensor data near the specified
value?
|

|
▶ Check for
poor connection between ECM and component: backed out
terminal, improper mating, broken locks or poor terminal to
wire connection. Repair as necessary and go to "Verification
of Vehicle Repair" procedure
|
|

|
▶
Substitute with a known-good HO2S and check for proper
operation. If the problem is corrected, replace HO2S and then
go to "Verification of Vehicle Repair"
procedure
|
|
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode |
| 2. |
Press F4(DTAL) and confirm that "DTC Readiness
Flag" indicates "Complete". If not, drive the vehicle within
conditions noted in the freeze frame data or enable
conditions. |
| 3. |
Read "DTC Status"
parameter |
| 4. |
Is parameter displayed "History(Not Present)
fault"?
|

|
▶ System
performing to specification at this time. Clear the
DTC
|
|

|
▶ Go to the
applicable troubleshooting
procedure.
|
|