| 2. |
Disconnect evaporator temperature
sensor. |
| 3. |
Using the multi-tester, Measure resistance
between terminal "1" and "2" of evaporator temperature
sensor.

[Specification]
Evaporator core
temperature [°C(°F)]
|
Resistance
[kΩ]
|
-10(14)
|
43.35
|
0(32)
|
27.62
|
10(50)
|
18.07
|
20
(68)
|
12.11
|
30(86)
|
8.30
|
40(104)
|
5.81
|
50(122)
|
4.15
|
|
| 4. |
If the measured resistance is not
specification, substitute with a known-good evaporator temperature
sensor and check for proper
operation. |
| 5. |
If the problem is corrected, replace the
evaporator temperature sensor. |
| 1. |
Remove the crash pad lower panel
(A).

|
| 3. |
Remove the Glove box houging (A).

|
| 4. |
Remove the shower duct (A).

|
| 5. |
Remove the evaporator temperature sensor (B),
by pulling it after rorating 90° in a counter clock wise
direction.

|
| 6. |
Installation is the reverse order of
removal | |