| 2. |
Using the multi-tester, Measure resistance
between terminal "1" and "2" of water temperature
sensor.

[Specification]
Coolant temperature
[°C(°F)]
|
Resistance
(kΩ)
|
Voltage
(V)
|
-10(14)
|
55.85 ± 3%
|
4.24 ± 3%
|
0(32)
|
32.91 ± 3%
|
3.83 ± 3%
|
10(50)
|
19.99 ± 3%
|
3.33 ± 3%
|
20(68)
|
12.51 ± 3%
|
2.78 ± 3%
|
30(86)
|
8.047 ± 3%
|
2.23 ± 3%
|
40(104)
|
5.311 ± 3%
|
1.73 ± 3%
|
50(122)
|
3.588 ± 3%
|
1.32 ± 3%
|
60(140)
|
2.476 ± 3%
|
0.99 ± 3%
|
70(158)
|
1.742 ±3%
|
0.74 ± 3%
|
80(176)
|
1.246 ± 3%
|
0.55 ±
3%
|
|
| 3. |
If the measured resistance is not
specification, substitute with a known-good water temperature sensor
and check for proper operation. |
| 4. |
If the problem is corrected, replace the water
temperature sensor.
|
Negative type thermistor that resistance
will rise with lower temperature, and reduce with higher
temperature. | |
| 1. |
Disconnect the negative (-) battery
terminal. |
| 2. |
Remove the crashpad lower cover
(A).

|
| 3. |
Remove the crashpad lower
panal(A).

|
| 4. |
After loosening the mounting bolts, then the
reinforcing panel (A).

|
| 5. |
Remove the shower duct (A).

|
| 6. |
Disconnect the connector (A) of water
temperature sensor and then remove the water temperature sensor(B)
by pulling out.

|
Take care that wire of water temperature
sensor is not to be
damaged | |
| 7. |
Installation is the reverse order of
removal.
|
Apply caulk to the water temperature
sensor.
Make sure that there is no air
leakage | | |