The mode control
actuator mounted on heater unit adjusts position of mode door by operating
Direction Motor based on signal of A/C control unit. Pressing mode select
switch makes the mode control actuator shift in order of vent→ B/L → floor
→ mix.
Air conditioner Control
Module sets DTC B1250 if Feedback signal of Mode Actuator has been
detected over 4.9V for 0.3 seconds
Item
|
Detecting
Condition
|
Detecting
Condition
|
DTC
Strategy
|
|
| •
|
Short in signal circuit(Feedback
signal) |
| •
|
Faulty Air conditioner Control
Module | |
Enable
Conditions
|
|
Threshold
value
|
| •
|
Feedback signal of Mode Actuator has
been detected over 4.9V for 0.3
seconds | |
Failsafe
|
| •
|
Setting mode : VENT Fix at VENT
position |
| •
|
Setting mode : Except VENT Fix at DEF
position | |
※ Voltage value of potentiometer as a
function of mode door position.
Mode Door
Position
|
Voltage
|
VENT
|
0.3±0.15V
|
BI-LEVEL
|
1.4±0.4V
|
FLOOR
|
2.5±0.4V
|
MIX
|
3.6±0.4V
|
DEF
|
4.7±0.15V
|
| Diagnostic Circuit
Diagram |

| 1. |
Connect scantool with diagnostic
connector. |
| 2. |
Warm up the engine to normal engine
temperature after engine starts. |
| 3. |
Select and monitor "Direction Potention"
parameter on scantool. |
| 4. |
Select and perform Actuation test Driver Mode
Door - Face / Foot / Defrost in
order. |
| 5. |
Check that the value of all the parameters are
changed when performing the actuation test.
Specification
: Face - About below 10%, Foot : About
50%, Defrost : About 90%.
|

|
| 6. |
Are all the parameters changed when performing
Actuation test ?
|

|
▶ This is a
intermittent problem caused by poor contact of component or
Control Unit ▶ Thoroughly check the
looseness, poor connection, bent, corrison, contamination,
deformation or damage of connector. ▶ Repair or replace as necessary and then, go to
"Verification of Vehicle Repair" procedure.
|
|

|
▶ Go to "
Inspection/Repair "
procedure.
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals. Faults can also be caused by
interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,or
damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification of Vehicle Repair"
procedure
|
|

|
▶ Go to
"W/Harness Inspection"
procedure.
|
|
| Signal Circuit
Inspection |
| ■ Check short to
battery in harness |
| 2. |
Disconnect Driver Direction actuator and A/C
control unit main harness
connector. |
| 4. |
Measure voltage between Signal(F/B) terminal
of Driver Direction actuator harness connector and chassis ground
.
|
| 5. |
Is the measured voltage within
specification?
|

|
▶ Go to
"Ground circuit Inspection " procedure.
|
|

|
▶ Check for
short to battery in harness. ▶
Repair as necessary and then go to "Verification of Vehicle
Repair"
procedure.
|
|
| Ground Circuit
Inspection |
| ■ Check for open in
harness |
| 2. |
Disconnect Driver Direction actuator and A/C
control unit main harness
connector. |
| 3. |
Measure resistance between Sensor ground(-)
terminal of Driver Direction actuator harness connector and Sensor
ground(-) terminal of A/C-ECU harness connector.
|
| 4. |
Is the measured resistance within
specification?
|

|
▶ Go to "
Component inspection " procedure .
|
|

|
▶ Check for
open in harness. ▶ Repair as
necessary and then go to "Verification of Vehicle Repair"
procedure.
|
|
| ■ Check Driver
Direction actuator |
| 2. |
Disconnect Driver Direction actuator and A/C
control unit main harness
connector. |
| 3. |
Connect(+) terminal of battery to DEF(+) of
Driver Direction actuator and (-) terminal to VENT(-). (Component
side) |
| 4. |
Verify that the temperature actuator operates
to the cool position |
| 5. |
Verify that the temperature actuator operates
to the warm position with reverse connecting. ( DEF(+) and VENT(-)
). (Component side)
Specification
: Refer the specifications in
Fig.1)
|
Fig.1)
Actuator
harness
|
DEF (+)
|
VENT (-)
|
Door
position
|
Battery terminal
|
12
V
|
ground
|
VENT.Mode
|
ground
|
12
V
|
DEF.Mode
|
FIG.1) ※ Function of the actuator motor
according to terminal connection type. (observe safety
regulations) |
| 6. |
Is "Door position" display near the specified
value?
|

|
▶ Go to
"Check potentiometer" procedure.
|
|

|
▶
Substitute with a known-good Driver Direction actuator and
check for proper operation. If the problem is corrected,
replace Driver Direction actuator and then go to "Verification
of Vehicle Repair"
procedure.
|
|
| 2. |
Connect Driver Direction actuator and A/C
control unit main harness
connector. |
| 4. |
Measure voltage between Signal(F/B) terminal
of Driver Direction actuator harness connector and Sensor ground(-)
terminal of A/C-ECU harness connector. (Component side)
Specification
: Refer the specifications in
Fig.2)
|
Fig.2)
Mode Door
Position
|
Voltage
|
VENT
|
0.3±0.15V
|
BI-LEVEL
|
1.4±0.4V
|
FLOOR
|
2.5±0.4V
|
MIX
|
3.6±0.4V
|
DEF
|
4.7±0.15V
|
Fig.2) ※ Voltage value of Direction
potentiometer as a function of position of mode
switch |
| 5. |
Is "voltage" display near the specified
value?
|

|
▶ Check
connectors for looseness, poor connection, bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and then go to "Verification of Vehicle Repair"
procedure.
|
|

|
▶
Substitute with a known-good Driver Direction actuator and
check for proper operation. If the problem is corrected,
replace Driver Direction actuator and then go to "Verification
of Vehicle Repair"
procedure.
|
|
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and selet "Diagnostic Trouble
Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on the
scantool. |
| 3. |
Are any DTCs present?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System is
performing to specification at this
time.
|
|