Home › Heating,Ventilation, Air Conditioning › Heater › Mode Control Actuator

Heater › Mode Control Actuator: Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect the connector of mode control actuator.
3.
Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3 and grounding terminal 4.
4.
Verify that the mode control actuator operates to the vent mode when connecting in the reverse.

5.
Check the voltage between terminals 5 and 6.
Door position
Voltage (5-6)
Error detecting
Vent
0.3 ± 0.15V
Low voltage : 0.1V or less
Defrost
4.7 ± 0.15V
High voltage : 4.9V or more

It will feedback current position of actuator to controls.
6.
If the measured voltage is not with in specification, substitute with a known-good mode control actuator and check for proper operation.
7.
If the problem is corrected, replace the mode control actuator.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the driver's crash pad lower panel. (Refer to BD group crash pad)
3.
Disconnect the mode control actuator connector after removing the air duct.
4.
Loosen the mounting screws and then remove the mode control actuator (B).

5.