The evaporative emission
control system prevents hydrocarbon vapors from escaping from the fuel
tank into the atmosphere where they could form photochemical smog.
Gasoline vapors are collected in the charcoal canister. The Fuel Tank
Pressure Sensor (FTPS) is installed on the canister and is an integral
part of the evaporative monitoring system. The PCM monitors the FTPS
signal to detect vacuum decay and excess vacuum. The FTPS measures the
difference between the air pressure inside the fuel tank and outside air
pressure to check the purge control solenoid valve operation and for leak
detection in the evaporative emission control system by monitoring
pressure and vacuum levels in the fuel tank during the purge control
solenoid valve operating cycles.
|