Home › Heating,Ventilation, Air Conditioning › Controller › Heater & A/C Control Unit(Full Automatic)

Controller › Heater & A/C Control Unit(Full Automatic): Repair procedures

Self-diagnosis
1.
Self-diagnosis process
The F.A.T.C. module self test feature will detect electrical malfunction and provide error codes for system components with suspected failures.

DTC data can be retrieved from the control panel directly or from the DLC using the Hi-Scan Pro.
2.
How to read self-diagnostic code
After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup temperature display panel every 0.5 second and will show two figures. Codes are displayed in numerical format.
Fault code
Fault code
Fail description
Control unit
00
Normal
11
In-car temperature sensor open (High)
12
In-car temperature sensor short (Low)
13
Ambient temperature sensor open (High)
14
Ambient temperature sensor short (Low)
15
Water temperature sensor open (High)
16
Water temperature sensor short (Low)
17
Evaporator temperature sensor open (High)
18
Evaporator temperature sensor short (Low)
19
Temp door potentiometer open/short
20
Temp door motor
21
Vent mode door potentiometer open/short
22
Vent mode door control motor
25
Intake door potentiometer open/short
26
Intake door potentiometer motor
27
AQS sensor open
28
AQS sensor short
31
AQS sensor fault
34
Floor mode door potentiometer open/short
35
Floor mode door potentiometer motor
36
Def mode door potentiometer open/short
37
Def mode door potentiometor motor

3.
Fault code display
(1)
Continuance operation : DTC code is one

(2)
Continuance operation : DTC code is more two

(3)
Step operation
A.
Nomal or one fault code is same a continuance
B.
DTC code is more two

4.
If fault codes are displayed during the check, Inspect malfunction causes by referring to fault codes.
5.
Fail safe
(1)
In-car temperature sensor: Control with the value of 23°C (73.4°F)
(2)
Ambient temperature sensor: Control with the value of 20°C (67°F)
(3)
Evaporator temperature sensor: Control with the value of -2°C (28.4°F)
(4)
Photo sensor: Control with the value of 10 W/m
(5)
Temperature control actuator (Air mix potentiometer):
A.
If temperature set 15°C-22.5°C, fix at maximum cooling position.
B.
If temperature set 23°C-30°C, fix at maximum heating position.
(6)
Mode control actuator (Direction potentiometer):
A.
INDICATOR OFF : Door close position
B.
INDICATOR ON : Door open position
(7)
Intake control actuator
A.
Fix fresh position, while selecting fresh mode.
B.
Fix recirculation position, while selecting recirculation mode.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the mat (A).

3.
Remove the upper tray (A).

4.
Remove the center facia lower panel (B) by pulling it using a screw driver (-) after losening a screw. Take care of fixing clips.

5.
Disconnect the connectors (A) from the center facia.

6.
Remove the heater & A/C controller (A) after loosening the screw.

7.
Installation is the reverse order of removal.