Lighting System › Hazard Lamp Switch: Repair procedures
Inspection
Hazard
Lamp Switch
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the center fascia upper
tray(A)
(Refer to the Body group - Crash
pad)
3.
Remove the crash pad center facia panel
(A).
Take care not to scratch the crash pad
and related parts.
4.
Disconnect the hazard lamp switch
connector.
5.
Operate the switch and check for continuity
between terminals with an ohmmeter.
Hazard
Lamp Relay
1.
Disconnect the negative (-) battery
terminal.
2.
Disconnect the ICM relay box
connector.
3.
Check for continuity between terminals.
There should be continuity between the No.3 and No.12 or No.7 of
ICM-B terminals when power and ground are connected to the No.3 and
No.17 of ICM-B terminals.
4.
There should be no continuity between the
No.3 and No.12 or No.7 of ICM-B terminals when power is disconnected