Home › Heating,Ventilation, Air Conditioning › Air conditioning System › Evaporator temperature sensor

Air conditioning System › Evaporator temperature sensor: Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect evaporator temperature sensor.
3.
Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

[Specification]
Evaporator core temperature [°C(°F)]
Resistance [kΩ]
-10(14)
43.35
0(32)
27.62
10(50)
18.07
20 (68)
12.11
30(86)
8.30
40(104)
5.81
50(122)
4.15

4.
If the measured resistance is not specification, substitute with a known-good evaporator temperature sensor and check for proper operation.
5.
If the problem is corrected, replace the evaporator temperature sensor.
Replacement
1.
Remove the crash pad lower panel (A).

2.
Remove the glove box.
3.
Remove the Glove box houging (A).

4.
Remove the shower duct (A).

5.
Remove the evaporator temperature sensor (B), by pulling it after rorating 90° in a counter clock wise direction.

6.
Installation is the reverse order of removal