Home
›
Engine Control/Fuel System
›
Engine Control System
›
Canister Close Valve (CCV)
Engine Control System › Canister Close Valve (CCV): Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the CCV connector.
3.
Measure resistance between the CCV terminal 5 and6.
4.
Check that the resistance is within the specification.
Specification:
Refer to "Specification"
5.
Disconnect the vapor hose connected with the canister from the CCV.
6.
Connect a vacuum pump to the nipple.
7.
Ground the CCV control line and apply battery voltage to the CCV power supply line.
8.
Apply vacuum and check the valve operation.
Specification:
Vacuum maintained