Home › Body Electrical System › Seat Electrical › Seat Heater

Seat Electrical › Seat Heater: Repair procedures

Inspection
1.
For back side of seat warmer, check for continuity and measure the resistance between No.1 and No.2 terminal of back connector.


Standard value
Cushion : 1.32Ω ± 10%, Back : 1.30Ω ± 10%

2.
Operate the seat warmer after connecting the connectors, and then check the NTC(Negative Temperature Coefficient) thermostat by measuring the temperature of seat surface.
Standard value
Item
Cushion
Back
Remark
LOW
97°F (36°C)
104°F (40°C)
±36°F (±2°C)
HIGH
104°F (40°C)
115°F (46°C)
±36°F (±2°C)

(Back high only : +36°F, -34°F(+2°C, -1°C))