Home › Heating,Ventilation, Air Conditioning › Air conditioning System › Ambient sensor

Air conditioning System › Ambient sensor: Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect ambient temperature sensor.
3.
Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.

[Specification]
Ambient Temperature
[°C (°F)]
Resistance (kΩ ± 3% )
-20
290.17
-10
165.79
0
97.83
10
59.67
20
37.47
30
24.17
40
15.99
50
10.82

4.
If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
5.
If the problem is corrected, replace the ambient temperature sensor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the front bumper.
(Refer to BD group - Front bumper)
3.
Remove the ambient temperature sensor (A).

4.
Installation is the reverse order of removal.