Heated Oxygen Sensor
(HO2S) consists of zirconium and alumina and is installed on upstream and
downstream of the Manifold Catalytic Converter (MCC).
After it compares
oxygen consistency of the atmosphere with the exhaust gas, it transfers
the corresponding voltage signal to the ECM. When A/F ratio is rich or
lean, it generates approximately +1V or 0V respectively.
In order that this
sensor normally operates, the temperature of the sensor tip must be higher
than predetermined temperature. So it has a heater which is controlled by
the ECM duty signal. When the exhaust gas temperature is lower than the
specified value, the heater warms the sensor tip.
|