Smart Junction Box(SJB)
| 1. |
General function : Interior Junction Box +
some functions of BCM
It controls loads with CAN communication and
IPS. |
| 2. |
Main function
| A. |
Low speed CAN communication(100
kbps) |
| B. |
Self diagnostics(Lamp
open/short) |
| C. |
Fail safe(When MCU/CAN is fail, Head
lamp / Tail lamp directly
drive) |
| D. |
Protection of bulb over-voltage(PWM
function) |
| E. |
Cut of Over-load and Short : PCL(Program
Current Limit) |
Switch control input
No.
|
Switch
input
|
Value
|
Destination
|
Wakeup
|
1
|
IG1
|
ON/OFF
|
-
|
YES
|
2
|
IG2
|
ON/OFF
|
-
|
NO
|
3
|
Seat belt
switch(Driver)
|
BELT/UNBELT
|
BCM
|
NO
|
4
|
Seat belt
switch(Passenger)
|
BELT/UNBELT
|
BCM
|
NO
|
5
|
Seat belt
switch(Rear left)
|
BELT/UNBELT
|
BCM
|
NO
|
6
|
Seat belt
switch(Rear right)
|
BELT/UNBELT
|
BCM
|
NO
|
7
|
Seat belt
switch(Rear center)
|
BELT/UNBELT
|
BCM
|
NO
|
8
|
Unlock
State(Driver door)
|
LOCK/UNLOCK
|
BCM,SMK
|
YES
|
9
|
Unlock
State(Passenger door)
|
LOCK/UNLOCK
|
BCM,SMK
|
YES
|
10
|
Unlock
State(Rear left door)
|
LOCK/UNLOCK
|
BCM
|
YES
|
11
|
Unlock
State(Rear right door)
|
LOCK/UNLOCK
|
BCM
|
YES
|
12
|
Driver
door switch
|
CLOSE/OPEN
|
BCM,CLU,SMK
|
YES
|
13
|
Passenger
door switch
|
CLOSE/OPEN
|
BCM,CLU,SMK
|
YES
|
14
|
Rear left
door switch
|
CLOSE/OPEN
|
BCM,CLU,SMK
|
YES
|
15
|
Rear
right door switch
|
CLOSE/OPEN
|
BCM,CLU,SMK
|
YES
|
16
|
Driver/Passenger door Key lock
|
OFF/LOCK
|
BCM
|
YES
|
17
|
Driver
door Key unlock
|
OFF/UNLOCK
|
BCM
|
YES
|
18
|
Passenger
door Key unlock
|
OFF/UNLOCK
|
BCM
|
YES
|
19
|
Driver
window lock switch
|
OFF/LOCK
|
BCM
|
YES
|
20
|
Driver
window unlock switch
|
OFF/UNLOCK
|
BCM
|
YES
|
21
|
Turn
signal switch(Left)
|
ON/OFF
|
CLU
|
NO
|
22
|
Turn
signal switch(right)
|
ON/OFF
|
CLU
|
NO
|
23
|
Hazard
switch
|
ON/OFF
|
-
|
YES
|
24
|
Trunk
switch
|
CLOSE/OPEN
|
BCM,CLU,SMK
|
YES
|
25
|
HID
|
HID/OFF
|
-
|
NO
|
26
|
Brake
fluid sensor
|
ON/OFF
|
CLU
|
NO
|
27
|
Parking
brake switch
|
ON/OFF
|
BCM,CLU
|
NO
|
28
|
Multifunction switch(Lighting)
|
ON/OFF
|
-
|
NO
|
29
|
Hood
switch
|
OFF/OPEN
|
BCM
|
YES
|
30
|
Trunk
release switch
|
ON/OFF
|
BCM,SMK
|
YES
|
Relay output control
No
|
Relay
output
|
Value
|
Type
|
Remarks
|
1
|
Auto
cut
|
ON/OFF
|
Transistor
|
Auto cut
of Dark current
|
2
|
Sound
relay
|
ON/OFF
|
Transistor
|
|
3
|
Door lock
relay
|
ON/OFF
|
LSD
|
|
4
|
Door
unlock relay
|
ON/OFF
|
LSD
|
|
5
|
Power
window main relay
|
ON/OFF
|
Transistor
|
|
6
|
Rear
heater relay
|
ON/OFF
|
LSD
|
|
7
|
Front
deicer relay
|
ON/OFF
|
LSD
|
|
8
|
Burglar
alarm relay
|
ON/OFF
|
LSD
|
|
9
|
Burglar
horn relay
|
ON/OFF
|
LSD
|
|
10
|
T/TURN
and D/LOCK
|
ON/OFF
|
LSD
|
|
11
|
Trunk lid
relay
|
ON/OFF
|
Transistor
|
|
Lamp control
No
|
Lamp
|
Bulb
capacity
|
PWM control
|
PCL
detection
|
OCL
detection
|
1
|
Head lamp
High(Left)
|
55
W
|
O
|
O
|
|
2
|
Head lamp
Low(Left)
|
55
W
|
O
|
O
|
|
3
|
Rear turn
signal(Left)
|
33
W
|
|
O
|
O
|
4
|
Front
turn signal(Left)
|
28
W
|
|
O
|
O
|
5
|
Head lamp
High(Right)
|
55
W
|
O
|
O
|
|
6
|
Head lamp
Low(Right)
|
55
W
|
O
|
O
|
|
7
|
Rear turn
signal(Right)
|
33
W
|
|
O
|
O
|
8
|
Front
turn signal(Right)
|
28
W
|
|
O
|
O
|
9
|
Tail
lamp(Left, right)
|
72
W
|
|
O
|
|
10
|
Interior
tail lamp
|
60
W
|
|
O
|
|
11
|
Front fog
lamp(Left, right)
|
70W(35W+35W)
|
O
|
O
|
|
*PCL(Programmable Current Limit) : It detects
the current of lamp. If a current exceed the standard value, it cuts
the current of lamp.
*OCL(Open Circuit Limit) : It detects the
current of lamp. If a current is below the standard value, it
controls current of lamp. |
Auto cut system of dark current

| 1. |
Description : It cuts automatically power to
be provided with load for reducing useless dark current according to
vehicle state.

|
| 2. |
SJB had 3 modes, "Normal Mode", "Sleep Mode",
"Power Off Mode". Auto cut of dark current practice in "Sleep
Mode".
| A. |
"Sleep" condition : IG OFF, constant
input switch, CAN network doesn't
activate. |
| B. |
"Sleep" resolutive condition : Any
switch inputs, CAN network activates, KEY ON, IGN
ON |
| C. |
"Power OFF" condition : The setting time
of timer which is used by cutting a load power
expires. |
| D. |
"Normal Mode" : SJB function normally
activates. |
| E. |
"Sleep Mode" : It is low power mode and
activates for reducing electricity consumption of SJB or IPM.
Auto cut of dark current function
activates. |
| F. |
"Power OFF Mode" : Power of MCU and
circumferential circuit is cut for minimizing electricity
consumption. Operation
stops. | |
| 3. |
The explanation - The auto cut of dark
current

Before
delivering to customer
|
Figure
|
•All door
close & RKE door lock or Constant switch
state (Auto cut of dark current
scenario starts.) -After
"sleep" state is for 20 min. -SJB power down(SJB dark current : 200 μA)
and cutting power of Lamp/Body Load/Wake up
|

|
After
delivering to customer
|
Figure
|
•All door
close & Constant switch state :
C_BAState=OFF (Auto cut of dark
current scenario starts.) -After "sleep" state is for 20
min. -SJB power down(SJB dark
current : 200 μA) and cutting power of Lamp
Load •In case RKE door lock :
C_BAState=ON & Trunk SW=CLOSE (Auto cut of dark current scenario
starts.) -After "Sleep" state
35s~65s (Waiting time of other unit : 30~60s + SJB sleep
counts 5s) -SJB Powerdown(SJB
dark current : 200 μA) and cutting power of Lamp
Load
|

|
|
| 4. |
Problem when mode switch setting is
wrong
: If a mode switch is set to OFF(Before
delivering to customer) by a customer or technician and auto cut
function of dark current activates, below problems may
happen.
Symptom
|
Related
part
|
•Door
lock/unlock, trunk open don't activate by RKE. (Wakeup of each module don't
activate.)
|
BCM
|
•Digital
clock is reset.(Memory is reset.)
|
Digital
clock
|
•Setting
value of audio(Volume, Frequency setting) is
reset. (Memory is
reset.)
|
Audio
|
*If mode switch OFF(before delivering to
customer) is set, power of BCM, Digital clock and audio is shut
off. | |