Heated Oxygen Sensor
(HO2S) consists of zirconium and alumina and is installed both upstream
and downstream of the Catalytic Converter. It varies in accordance with
the air/fuel ratio.
The sensor must be hot
in order to operate normally. To keep it hot, the sensor has a heater
which is controlled by the ECM via a duty cycle signal. When the exhaust
gas temperature is lower than the specified value, the heater warms the
sensor tip.
|