| 1. |
Disconnect the battery negative terminal
first, then the positive terminal.
Tightening
torque
(+) terminal:
7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~
7.2 lb-ft)
(-) terminal:
4.0 ~ 6.0 N.m (0.4 ~ 0.6 kgf.m, 3.0 ~
4.4 lb-ft)
| |
| 2. |
Remove the drive belt (B) after loosening the
belt tension by turning the bolt adjusting (A)
counterclockwise.

|
| 3. |
Disconnect the alternator connector (A) and
the cable (B) from alternator "B" terminal.
Tightening
torque:
9.8 ~ 14.7 N.m (1.0 ~ 1.5 kgf.m, 7.2 ~
10.8 lb-ft)
|

|
| 4. |
Pull out the through bolt and then remove the
alternator (A).
Tightening
torque
M10 bolt:
29.4 ~ 41.2 N.m (3.0 ~ 4.2 kgf.m, 21.7 ~
30.4 Ib-ft)
M8 bolt:
21.6 ~ 32.4 N.m (2.2 ~ 3.3 kgf.m, 15.9 ~
23.9 Ib-ft)
|

|
| 5. |
Installation is the reverse order of
removal. |
| 1. |
Loosen the nuts (B) and then remove the cover
(A).

|
| 2. |
Loosen the mounting bolts (A) and remove the
regulator assembly (B).

|
| 3. |
Remove the slip ring guide (A).

|
| 4. |
Using the SST (09373-27000), remove the pulley
(A).

|
| 5. |
Loosen the 4 bolts (A) and then remove the
rear housing (B).

|
| 6. |
Disconnect the rotor (A) and the housing
(B).

|
| 7. |
Reassembly is the reverse order of
disassembly. |
Inspect Rotor
| 1. |
Check that there is continuity between the
slip rings (C). |
| 2. |
Check that there is no continuity between the
slip rings and the rotor (B) or rotor shaft (A).

|
| 3. |
If the rotor fails either continuity check,
replace the alternator. |
Inspect Stator
| 1. |
Check that there is continuity between each
pair of leads (A).

|
| 2. |
Check that there is no continuity between each
lead and the coil core. |
| 3. |
If the coil fails either continuity check,
replace the
alternator. | |