Body control module
receives various input switch signals controlling time and alarm functions
for the intermittent wiper timer, washer timer, rear defogger timer, seat
belts warning, central door lock, ignition key reminder, power window,
door warning, tail lamp, crash door unlock, ignition key hole
illumination, rear fog lamp control and keyless entry & burglar
alarm.
BCM, SJB(Smart
Junction Box) and CLU(Instrument Cluster) are connected by CAN
line.
The nearest module
with input switch or actuator receives the input data to reduce the wiring
and then send input data to the others which need them via CAN lines.
In case of sending
output, it is used to CAN communication, not wiring.
SJB can also control
relays and IPS.
So Each module allots
the current data and actuation data.

Wiper
Control
| Washer Control
Coupled With Wiper |

| 1. |
Under IGN2 = ON, wiper LOW relay is turned
ON after T2 from Washer switch ON if washer switch is ON for T1 and
wiper LOW relay is turned OFF after T3.

T1:0.06s~0.2s, T2:0.3s ±0.1s, T3:0.7s ±0.1s
|
| 2. |
Under IGN2 switch ON, wiper LOW relay is
turned ON after T2 from Washer switch ON if washer switch is ON for
at least T1, and wiper LOW relay is turned OFF after T3 from the
moment that Washer switch is turned OFF.

T1:0.2s(MIN), T2:0.3s ±0.1s
T3:2.5s~3.8s(2~3
Turn) |
| 3. |
Operation in Item (2) is performed if Washer
switch is ON for at least T1 during WIPER operation with Wiper int
switch. Operation in Item (1) is performed if Washer switch is ON
for T6.

T1:0.2s(MIN) , T2:0.3s ±0.1s
T3:2.5s~3.8s(2~3 Turn), T4:T5 -
0.7s
T5:INT TIME, T6:0.06s ~0.2s, T7:0.7s
±0.1s |
| 4. |
Operation is cancelled in case of IGN OFF
during T3. |
| 5. |
Give priority to WASHER interlocking WIPER
than Speed sensing INT WIPER
function. |
| 6. |
Washer switch signal input shall be ignored
at start-up (IGN1 ON & IGN2 OFF
states). |
| 7. |
Switch ON time includes chattering
time |
Front
Wiper Mist Function Wiper

| 1. |
Function Description
In case of IGN2 On (IGN2 ON), if turning on
the Wiper Mist switch(Wiper Mist switch On), then Wiper is
controlled, by switch on time. Mist operation does not work at Wiper
Washer.
Mist
Switch On Time (TMist)
|
Action
|
TMist <
0sec
|
No
action
|
0sec ≤ TMist <
0.7sec
|
After “Mist Out
Delay Time”, turn on the Wiper Low Output for “One Wiping”
Time (the remaining motor operation to reach wiper park
position is done by electrical wiring)
|
0.7sec ≤
TMist
|
After “Mist Out
Delay Time”, turn on the Wiper Low Output and after Mist
switch off, Wiper Low Output is Off immediately (the remaining
motor operation to reach wiper park position is done by
electrical wiring)
|

T1 : One Wiping, T2 : Mist One
Time |
| 2. |
Under IGN2 switch ON, Wiper LOW relay is
turned ON immediately from Mist switch ON if Mist switch ON for more
than T1, Wiper LOW relay is turned OFF after T2 from Mist switch
OFF.

T1 : 0.7s(Min), T2 :
0.7s±0.1s |
Variable
Int Wiper

| 1. |
Under IGN2 switch ON & Wiper Int switch
ON states, and wiper int volume value are acquired and intermittent
time is calculated. then, wiper intermittent time is automatically
converted.

T1 : 0.7 ± 0.1s, T2 : INT Time( 2.2 ± 0.2s ~
10 ± 1s)
*1 ON : IGN2 = ON OFF: IGN2 =
OFF |
| 2. |
Wiper Control Precaution
| (1) |
Variable int wiper
| A. |
Wiper low relay time is 0.7s
±0.1s. |
| B. |
Intermittent time is from output
ON to the next output
ON. |
| C. |
Wiper low relay output is
continued for remaining ON time if INT switch is turned
OFF during output. |
| D. |
Intermittent time is restarted
when IGN2 switch is ON and wiper Int switch is changed
from OFF to ON. |
| E. |
Intermittent time is restarted
when wiper int switch is ON and IGN2 switch is changed
from OFF to ON |
| F. |
2.5V is used when volume value
is 2.5V or more.
Input
voltage (Volume)
|
Intermittent time
(sec)
±10%
|
Remarks
|
Speed is
fixed
|
0.0V
|
2.2 Sec
|
|
1.0V
|
3 Sec
|
|
1.5V
|
3.8 Sec
|
|
2.0V
|
5.6 Sec
|
|
2.5V
|
10 Sec
|
|
| | |
Buzzer
Control

Buzzer
Sound
| 1. |
Buzzer sound spec
Priority
|
Name
|
Cycle
|
Duration
|
1
|
RPAS
warning
|
-
|
-
|
2
|
Seatbelt
warning
|
1s /
Reductive
|
Spec
|
3
|
Overspeed
warning
|
-
|
-
|
4
|
Key operated
warning
|
1s /
Reductive
|
Infinite
|
5
|
Key learning
sound (NON SMK
option)
|
0.6s/Reductive
|
3s
|
6
|
Parking brake
warning
|
0.6s /
Reductive
|
Infinite
|

|
| 2. |
Buzzer output
Buzzer output to estimate BCM int buzzer in
cluster, and data transmission.
※ Internal buzzer is used for rear parking
assist system.
State
|
Description
|
Initial
Condition
|
IGN1
OFF
|
Event
|
C_DRV Seat Belt SW
is belted and IGN1=ON
|
Action
|
- Start 5.7
seconds driver indicator blinking - The automaton state is changed to IGN1 ON
DRIVER BELTED
|
State
|
Description
|
Initial
Condition
|
IGN1
OFF
|
Event
|
C_DRV Seat Belt SW
is unbelted and IGN1=ON
|
Action
|
- Start 6
seconds blinking for C_DRVSeatbeltIND -
Start 5.7 seconds warning for C_IntBuzzer - The automaton state is changed to IGN1 ON
DRIVER UNBELTED
|
State
|
Description
|
Initial
Condition
|
IGN1 ON DRIVER
BELTED
|
Event
|
IGN1=OFF
|
Action
|
- Stop 6
seconds blinking for C_DRVSeatbeltIND -
Stop 5.7 seconds warning for C_IntBuzzer - The automaton state is changed to IGN1
OFF
|
State
|
Description
|
Initial
Condition
|
IGN1 ON DRIVER
BELTED
|
Event
|
C_DRV Seat Belt SW
is unbelted
|
Action
|
- Start 6
seconds blinking for C_DRVSeatbeltIND -
Start 5.7 seconds warning for C_IntBuzzer - The automaton state is changed to IGN1 ON
DRIVER UNBELTED
|
State
|
Description
|
Initial
Condition
|
IGN1 ON DRIVER
UNBELTED
|
Event
|
IGN1=OFF
|
Action
|
- Stop 6
seconds blinking for C_DRVSeatbeltIND -
Stop 5.7 seconds warning for C_IntBuzzer - The automaton state is changed to IGN1
OFF
|
State
|
Description
|
Initial
Condition
|
IGN1 ON DRIVER
UNBELTED
|
Event
|
C_DRV Seat Belt SW
is belted
|
Action
|
- Stop 5.7
seconds warning for C_IntBuzzer -
The automaton state is changed to IGN1 ON DRIVER
BELTED
|

|
Seat
belt reminder (Driver seat)

| 1. |
From IGN1 switch ON, Warning lamp for 1sec
(DUTY 50%) and Chime buzzer for 6 time every 1sec. (in case of
S/BELT unfastened state) But, within 6sec in the S/BELT fastened,
the Chime buzzer output is stop, and Warning lamp is the remaining
time. |
| 2. |
Lamp and Chime buzzer become output stop
when IGN1 is turned OFF within
6sec-output. |
| 3. |
If vehicle speed over 10Km/h, Warning lamp
and Chime buzzer will operate when Seat belt unfastened after IGN
ON. |
| 4. |
If vehicle speed below 5Km/h or IGN OFF or
seat belt fastened, the pattern is
stopped. |
| 5. |
Seat belt fastened→unfastened when IGN1=ON
state : if vehicle speed over 10Km/h,1time output. And if vehicle
speed 5~10Km/h, Warning lamp for 1sec (DUTY 50%) and Chime buzzer
for 6 every 1s. If vehicle speed less than 5Km/h, Warning lamp for 6
every 1sec (DUTY 50%) |
Key
Operated Warning

| 1. |
Internal buzzer on every 1sec when driver
door switch is on and key ign on. |
| 2. |
Output is off if key ign is in off and
driver door switch closed are met during Internal buzzer
output. |
| 3. |
At IGN1 on, output is off.

T1 : 1 ± 0.1sec
KEY IN ON : Key in switch ON or ACC ON or
fob in ON
KEY IN OFF : Key in switch OFF and ACC OFF
and fob in OFF |
Parking
Brake Warning

Parking Brake Warning Control Function
In/Out List
Function
|
Characteristics
|
Name
|
Hardware
Label
|
Spec.
Designation
|
Input
|
Logic
|
C_ParkingBrakeSW
|
Parking Brake
Switch
|
L_IGN1
|
Ignition 1
Input
|
CAN
Communication
|
C_VehicleSpeed
|
Vehicle Speed from
CLU
|
Output
|
CAN
Communication
|
C_IntBuzzer
|
Internal Warning
Buzzer
|
0 : OFF
/
|
1 : SeatBelt Warning
/
|
2 : Key Operated
Warning/
|
3 : Parking Brake Warning
/
|
4 :
Reserved
|
5 : Key Learning Sound(No
SMK Option)
|
6 :
default
|
| 1. |
Behavior Characteristics
If driver drives the vehicle with
non-parking brake or not completely released and vehicle speed
exceeds the specific value of 5km/h, a sound warning reminds the
driver that parking brake has to be released.

|
| 2. |
Parameter Values
Parking Brake Warning Buzzer Sound Characteristics
Type
|
Magnetic
Buzzer
|
Parking Brake
Warning Buzzer Sound frequency
|
800
Hz
|
Parking Brake
Warning Buzzer Sound Signal Duty Ratio
|
50%
Duty
|
Parking Brake
Warning Buzzer Sound Period
|
0.6 + 0.06
sec
|
Parking Brake
Warning Buzzer Sound duration
|
Infinite
|
|
IGN
Key Hole Illumination

Function
Description
| 1. |
O_KeyHoleIllumination is turned ON at L_IGN1
= OFF & C_DRVDRSW(OR C_ASTDRSW) =
OPEN. |
| 2. |
After 20min at (1) State,
O_KeyHoleIllumination output is turned
OFF. |
| 3. |
At (1) State, if C_DRVDRSW(OR C_ASTDRSW ) is
closed O_KeyHoleIllumination output continue ON state during 30s and
after turned OFF. |
| 4. |
At (1) State, when L_IGN1 is turned ON
O_KeyHoleIllumination is immediately turned
OFF. |
| 5. |
If ATWS state are ON, O_KeyHoleIllumination
is immediately turned OFF.

T1 : 30 ±
1sec |
Defogger
& Deicer Timer Control

Defogger
& Front Deicer Timer
| 1. |
Defogger relay & Front deicer relay is
turned ON for 20min if defogger switch ON after Alt L ON & IGN1
ON. |
| 2. |
Defogger relay & Front deicer relay is
turned OFF if again defogger switch ON during defogger relay
ON. |
| 3. |
Defogger relay & Front deicer relay is
turned OFF if AltL OFF or IGN1 OFF during defogger relay
ON. |
| 4. |
Defogger relay & Front deicer relay and
OFF of the output will remain at Defogger switch ON & Alt
LON.

T1 : 20 ±
1min |
Decayed
Room Lamp & Keyless Unlock Timer
| -
|
IGN1 off the door (Trunk excluded) will be
lit to open the room lamp. |
| -
|
Room lamp 4 Door closes, a 30-second delay
will be lights out. |
| -
|
4 Door in closed IGN1 off & (Key in →
Key out): 30-second delay will be lights out.

※ TX UNLOCK : Include UNLOCK by KEYLESS or
SMK
※ IGN KEY=IN->OUT
: IGN KEY=ON->OFF & ACC=ON->OFF
& IGN1=ON->OFF & IGN2=ON->OFF
※ b_4DOORSW
: b_4DOORSW = ON (C_DRVDRSW=OPEN or
C_ASTDRSW=OPEN or C_RLDRSW=OPEN or C_RRDRSW=OPEN)
: b_4DOORSW = OFF (C_DRVDRSW=CLOSE &
C_ASTDRSW=CLOSE & C_RLDRSW=CLOSE &
C_RRDRSW=CLOSE) |
Description
Of State
| 1. |
Room Lamp off
State
|
Description
|
Initial
Condition
|
Room lamp
decaying
|
Event
|
Decay
finished
|
Action
|
Room lamp
off
|

|
| 2. |
Room Lamp on
State
|
Description
|
Initial
Condition
|
Room Lamp
off
|
Event
|
IGN1 on & 4door
switch on
|
Action
|
Room Lamp
on
|

State
|
Description
|
Initial
Condition
|
Room Lamp
Decaying
|
Event
|
IGN1 on &
b_4DRSW=on
|
Action
|
Room Lamp
on
|
State
|
Description
|
Initial
Condition
|
Room Lamp on for
20min
|
Event
|
IGN1
on
|
Action
|
Room Lamp
on
|
|
| 3. |
Room Lamp on for 30s
State
|
Description
|
Initial
Condition
|
Room Lamp on for
30s
|
Event
|
TX Unlock or Key In
switch on→off
|
Action
|
Restart Room Lamp
on for 30s
|
State
|
Description
|
Initial
Condition
|
Room Lamp
on
|
Event
|
IGN1 off &
b_4DRSW=off
|
Action
|
Start Room Lamp on
for 30s
|

| - |
The flickering of lamp is not
allowed even though IGN1
ON |
| - |
The resolution of Decayed Room
Lamp must be more than 32
step. | |
State
|
Description
|
Initial
Condition
|
Room Lamp on for
20min
|
Event
|
IGN1 off &
b_4DRSW=off
|
Action
|
Start Room Lamp on
for 30s
|
State
|
Description
|
Initial
Condition
|
Room Lamp
Decaying
|
Event
|
IGN1 off &
b_4DRSW=off & (TX Unlock or
Key In switch on→off)
|
Action
|
Start Room Lamp on
for 30s
|
State
|
Description
|
Initial
Condition
|
Room Lamp
off
|
Event
|
IGN1 off &
b_4DRSW=off & (TX Unlock or
Key In switch on→off)
|
Action
|
Start Room Lamp on
for 30s
|
|
| 4. |
Room Lamp Decaying
State
|
Description
|
Initial
Condition
|
Room Lamp on for
30s
|
Event
|
IGN1 on or 30s
elapsed or Any Door Unlock→All
Door Lock1
|
Action
|
Start Room Lamp
Decaying
|

State
|
Description
|
Initial
Condition
|
Room Lamp
on
|
Event
|
IGN1 on or
b_4DRSW=off
|
Action
|
Start Room Lamp
Decaying
|
State
|
Description
|
Initial
Condition
|
Room Lamp on for
20min
|
Event
|
20min elapsed or
(IGN1 off & b_4DRSW=off & All Door
Lock1)
|
Action
|
Start Room Lamp
Decaying
|

|
| 5. |
Room Lamp on for 20min
State
|
Description
|
Initial
Condition
|
Room Lamp
off
|
Event
|
IGN1 off
& (b_4DRSW=off→on for
100ms)
|
Action
|
Start Room Lamp on
for 20min
|
State
|
Description
|
Initial
Condition
|
Room Lamp
Decaying
|
Event
|
IGN1 off &
(b_4DRSW=off→on for
100ms)
|
Action
|
Start Room Lamp on
for 20min
|
State
|
Description
|
Initial
Condition
|
Room Lamp on for
30s
|
Event
|
IGN1 off &
(b_4DRSW=off→on for
100ms)
|
Action
|
Start Room Lamp on
for 20min
|
State
|
Description
|
Initial
Condition
|
Room Lamp
on
|
Event
|
IGN1 off &
b_4DRSW=on
|
Action
|
Start Room Lamp on
for
20min
|
|
Power
Window Timer

Function
Description
| 1. |
Safety Power window Enable and power window
main output is turned ON at IGN1
ON. |
| 2. |
Maintaining output at IGN1 OFF after 30
seconds Safety Power window Enable and power window main, Safety
Power window Enable and power window main output is
OFF. |
| 3. |
Above (2) Driver door switch or Assist door
switch in protest to the conditions when you OPEN, Safety Power
window Enable and power window main output will be OFF
immediately. |
| 4. |
IGN1 OFF when the Safety Power window
Enable and power window main output is OFF at driver door switch or
Assist door switch OPEN.

T1 : 30 ±
3sec |
Door
Lock/unlock Control

Central
Door Lock/unlock
| 1. |
ALL DOOR LOCK output is ON during T1(0.5s)
if C_DRVUnlockState or C_ASTUnlockState is LOCK within 3sec after
C_DRVKeyLockSW is turned ON. But, KEY IN ON & L_IGN1 ON when
output is prohibited. |
| 2. |
C_DoorUnlockRly output is ON during T1(0.5s)
if C_DRVUnlockState is UNLOCK within 3sec after C_DRVKeyUnlockSW is
turned ON. |
| 3. |
C_DoorUnlockRly output is ON during T1(0.5s)
if C_ASTUnlockState is UNLOCK within 3sec after C_ASTKeyUnlockSW=ON
is turned ON. |
| 4. |
ALL DOOR LOCK output is ON during T1 at
TXLock ON or C_ C_SMKRKECMD = LOCK or C_PassiveLock
ON. |
| 5. |
ALL DOOR UNLOCK output is ON during T1 at
TXUnlock ON or C_ SMKRKECMD = UNLOCK or C_PassiveUnlock ON(NA
C_P_FR=ON). |
| 6. |
ALL DOOR LOCK output is ON during T1 at
C_PwdwDRLockSW=ON. |
| 7. |
ALL DOOR UNLOCK output is ON during T1 at
C_PwdwDRUnlockSW=ON. But, C_PwdwDRUnlockSW=ON signal is ignored in
ARM, ARMWAIT,REARM, ALARM state. |
| 8. |
LOCK/UNLOCK by (8) C_DRVUnlockState,
C_ASTUnlockState operation is not interlocked. (mechanical
operation) |
| 9. |
Shall be no malfunction at Battery
connection. (shall be no malfunction even at
L_KeyInSW). |
| 10. |
When the output of the reverse direction is
required and the current output immediately OFF, after 100ms delay
and output to the reverse. But, during 100ms delay when output is
required the output needs to eventually send us the
output. |
| 11. |
If LOCK output and UNLOCK output conditions
at the same time, LOCK output is done, and the UNLOCK output is
ignored. |
| 12. |
If ALL DOOR LOCK state of the output
conditions at ALL DOOR LOCK status, the actual output is not,and
ALL DOOR UNLOCK state of the output conditions at ALL DOOR UNLOCK
status, the actual output is not. |
| 13. |
ALL DOOR LOCK(UNLOCK) SW always output
LOCK(UNLOCK) requirement by C_PwdwDRLockSW(C_PwdwUnlockSW), TXLock,
TXUnlock, C_SMKRKECMD=LOCK,C_SMKRKECMD=UNLOCK, C_DRVKeyLockSW,
C_DRVKeyUnlockSW, C_ASTKeyUnlockSW regardless of LOCK(UNLOCK)
state. |
| 14. |
At IGN1 ON, LOCK output is prohibited by
DOOR KEY LOCK SW.

T1 : 0.5 ±
0.1sec |
2-Turn
Unlock
| 1. |
ALL DOOR UNLOCK output is ON during T3 if
C_DRVUnlockSW is UNLOCK within 3s andC_DRVKeyUnlockSW is OFF->ON
within T1 after C_DRVKeyUnlockSW is OFF -> ON (mechanically,
C_DRVUnlockSW is unlocked and BCM signal doesn’t
output). |
| 2. |
ALL DOOR UNLOCK output is ON during T3 if
C_DRVUnlockSW is UNLOCK within 3s and TXUnlock is received within T1
after C_DRVKeyUnlockSW is OFF -> ON (mechanically, C_DRVUnlockSW
is unlocked and BCM signal doesn’t
output). |
| 3. |
DRIVER DOOR UNLOCK output is ON during T3
when TXUlock signal is received. But, ALL DOOR UNLOCK output are ON
during T3 if TX Unlock signal is received within
T1. |
| 4. |
ALL DOOR UNLOCK output is ON during T3 if
C_DRVKeyUnlockSW is OFF->ON (mechanically,C_DRVUnlockSW is
unlocked and BCM signal doesn’t output) within T1 after TXUnlock
received and C_DRVUnlockSW is UNLOCK within
3s. |
| 5. |
When other registered TXUnlock signal is
received within T1, they are regarded as the same
TX. |
| 6. |
At C_DRVUnlockSW UNLOCK state, the DRIVER
DOOR UNLOCK requirement does not
output. |
| 7. |
DRIVER DOOR UNLOCK output will be according
to ALL DOOR UNLOCK output when the DRIVER DOORUNLOCK output of the
ALL DOOR UNLOCK output requirements.

T1 : 4 ± 1sec, T2 : 0.5 ±
0.1sec |
2-Turn
Unlock (SMK)
| 1. |
ALL DOOR UNLOCK output is ON during T3 if
C_DRVUnlockSW is UNLOCK within 3s and C_DRVKeyUnlockSW is OFF->ON
within T1 after C_DRVKeyUnlockSW is OFF -> ON (mechanically,
C_DRVUnlockSW is unlocked and BCM signal doesn’t
output). |
| 2. |
ALL DOOR UNLOCK output is ON during T3 if
C_DRVUnlockSW is UNLOCK within 3s and C_SMKRKECMD = UNLOCK is
received within T1 after C_DRVKeyUnlockSW is OFF -> ON
(mechanically, C_DRVUnlockSW is unlocked and BCM signal doesn’t
output). |
| 3. |
DRIVER DOOR UNLOCK output is ON during T3
when C_SMKRKECMD = UNLOCK signal is received. But, ALL DOOR UNLOCK
output are ON during T3 if C_SMKRKECMD = UNLOCK signal is received
within T1. |
| 4. |
ALL DOOR UNLOCK output is ON during T3 if
C_DRVKeyUnlockSW is OFF->ON (mechanically,C_DRVUnlockSW is
unlocked and BCM signal doesn’t output) within T1 after C_SMKRKECMD
= UNLOCK received and C_DRVUnlockSW is UNLOCK within
3s. |
| 5. |
DRIVER DOOR UNLOCK output is ON during T3
when C_PassiveUnlock ON & C_P_FL ON is input. But, ALL DOOR
UNLOCK output is ON during T3 if C_PassiveUnlock ON & C_P_FL ON
is input within T1. |
| 6. |
DRIVER DOOR UNLOCK output is ON during T3
when C_PassiveUnlock ON & C_P_FL ON is input. But, ALL DOOR
UNLOCK output is ON during T3 if C_DRVKeyUnlockSW is OFF -> ON
& C_P_FL ON is input within T1. |
| 7. |
DRIVER DOOR UNLOCK output is ON during T3
when C_PassiveUnlock ON & C_P_FL ON is input. But, ALL DOOR
UNLOCK output are ON during T3 if C_SMKRKECMD = UNLOCK is received
within T1. |
| 8. |
At C_DRVUnlockSW UNLOCK state, the DRIVER
DOOR UNLOCK requirement does not
output. |
| 9. |
DRIVER DOOR UNLOCK output will be according
to ALL DOOR UNLOCK output when the DRIVER DOORUNLOCK output of the
ALL DOOR UNLOCK output
requirements. |
IGN
Key Reminder
| 1. |
This function is not performed when vehicle
speed is more than 3km/h. |
| 2. |
ALL DOOR UNLOCK signal is output for 1s
after 0.5s from when the state becomes IGN KEY ON& C_DRVDRSW =
OPEN & C_DRVUnlockState = LOCK.(Except
NA) |
| 3. |
DRIVER DOOR UNLOCK signal is output for 1s
after 0.5s from when the state becomes IGN KEY ON& C_DRVDRSW =
OPEN & C_DRVUnlockState = LOCK.(Only
NA) |
| 4. |
ALL DOOR UNLOCK signal is output for 1s
after 0.5s from when the state becomes IGN KEY ON & C_ASTDRSW =
OPEN & C_ASTUnlockState = LOCK. |
| 5. |
ALL DOOR UNLOCK signal is output for 1s
after 0.5 from when (1),(2),(3) concurrent satisfaction, (3)
paragraph pursuant (Except DEAD
LOCK) |
| 6. |
UNLOCK signal is output 3 times as Max
(1s-output is excluded) in case LOCK state is held even when UNLOCK
signal is output for 1s in (2),(3),(4). (1s cycle: 0.5s
ON/OFF) |
| 7. |
After (6) of Section, when C_DRVDRSW is
CLOSE CENTRAL UNLOCK in the LOCK state attempts one-time
attempt. |
| 8. |
ALL DOOR UNLOCK signal is output (only once)
during 1s if C_DRVDRSW is CLOSE within 0.5s from C_DRVUnlockState
UNLOCK -> LOCK under IGN KEY ON.(Except
NA) |
| 9. |
DRIVER DOOR UNLOCK signal is output (only
once) during 1s if C_DRVDRSW is CLOSE within 0.5s from
C_DRVUnlockState UNLOCK -> LOCK under IGN KEY ON.(Only
NA) |
| 10. |
ALL DOOR UNLOCK signal is output (only once)
during 1s if C_ASTDRSW is CLOSE within 0.5s from C_ASTUnlockState
UNLOCK -> LOCK under IGN KEY ON.
|
| 11. |
ALL DOOR UNLOCK signal is output (only once)
during 1s if C_DRVUnlockState is UNLOCK->LOCK within 0.5s from
C_DRVDRSW OPEN -> CLOSE under IGN KEY ON.(Except
NA) |
| 12. |
DRIVER DOOR UNLOCK signal is output during
1s if C_DRVUnlockState is UNLOCK->LOCK within 0.5s from C_DRVDRSW
OPEN -> CLOSE under IGN KEY ON.(Only
NA) |
| 13. |
ALL DOOR UNLOCK signal is output (only once)
during 1s if C_ASTUnlockState is UNLOCK->LOCK within 0.5s from
C_ASTDRSW OPEN -> CLOSE under IGN KEY
ON. |
| 14. |
At IGN KEY=ON after C_DRVDRSW or C_ASTDRSW
is OPEN if the C_PwdwDRLockSW ON, KEY REMINDER function is
performed. |
| 15. |
Judgment of the possibility of RETRY signal
output is performed at RETRY signal output start.
(after 1.5s from the first UNLOCK signal
output) |
| 16. |
After the condition if UNLOCK is met, UNLOCK
signal is output if the condition is not held for 0.5s. But, UNLOCK
signal is not output if KEY IN is OFF at the moment that 0.5s passes
after the condition is met by C_DRVUnlockState or C_ASTUnlockState
change from UNLOCK to LOCK.

T1,T3 : 0.5 ± 0.1sec, T2 : 1 ± 0.1sec, T4 :
0.5sec Max
KEY IN ON : Key in ON or ACC = 1 or IGN1 ON
or IGN2 ON
KEY IN OFF : Key in OFF and ACC =0 and IGN1
OFF and IGN2 OFF |
IGN KEY ON : Key in
switch(Fob in) ON or ACC ON or IGN1 ON or IGN2 ON
IGN KEY OFF : Key in
switch(Fob in) OFF and ACC OFF and IGN1 OFF and IGN2 OFF
Passive
Key Reminder Unlock (SMK)
| 1. |
This function is not performed when vehicle
speed is 3km/h or more. |
| 2. |
When the driver door switch (Assist door
switch) = OPEN and driver unlock state (Assist unlock state) are
lock state, passive KEY REMINDER signal received at the output ALL
DOOR UNLOCK is for 1s. |
| 3. |
UNLOCK signal is output 3 times as Max
(1s-output is excluded) in case LOCK state is held even when UNLOCK
signal is output for 1s in (2). (1s cycle: 0.5s ON/OFF)

T1 : 1 ± 0.1sec, T2 : 0.5 ±
1sec |
Crash
Door Unlock
| 1. |
When IGN1 = ON, L_CRASH INPUT signal starts
to judge ON/OFF from T1(1s), When IGN_KEY_OFF, L_CRASH INPUT signal
terminates to judge ON/OFF. |
| 2. |
After L_CRASH INPUT signal starts to judge
ON/OFF and IGN_KEY_ON states , if L_CRASH INPUT is ON then ALL DOOR
UNLOCK is output for T2(5s) (CRASH UNLOCK OUTPUT)
* L_CRASH INPUT signal is determined L_CRASH
INPUT = ON, when 16ms_LOW / 4ms_HIGH cycle is input 1
time.
* In BCM SLEEP state, L_CRASH INPUT is
ignored. |
| 3. |
After above (2) Section. even if IGN KEY is
ON → OFF during the CRASH UNLOCK output, CRASH UNLOCK is maintained
for the remaining time. |
| 4. |
After above (2) Section. If L_CRASH INPUT is
ignored to input again during CRASH UNLOCK output for
T2. |
| 5. |
CRASH UNLOCK output before BCM SLEEP states
to the ANY DOOR UNLOCK→LOCK then ALL DOOR UNLOCK output is performed
during T2. |
| 6. |
CRASH DOOR UNLOCK condition, AUTO DOOR LOCK
does not function. |
| 7. |
CRASH DOOR UNLOCK function overrides LOCK /
UNLOCK control by other functions. |
| 8. |
DOOR UNLOCK is outputting and after output,
LOCK / UNLOCK request by other function is
ignored. |
| 9. |
After CRASH DOOR UNLOCK, to enter BCM SLEEP
states or L_KEY IN = OFF & L_ACC = OFF &L_IGN1 = OFF &
L_IGN2 = OFF are became then LOCK / UNLOCK control by the other
function is performed.

T1 : 5.0 sec
* IGN KEY_ON : ON == KEY IN or ACC ON or
IGN1 ON or IGN2 ON
OFF == KEY OUT & ACC OFF & IGN1 OFF
& IGN2 OFF |
| 10. |
L_CrashInput for the input signal ON / OFF
judging criteria are the following figure.

T1 : 1 ± 0.1sec, T2 : 0.5±
0.1sec |
Auto
Door Lock/unlock Control (User Option)
| 1. |
ALL DOOR LOCK signal is output if vehicle
speed is 15km/h within T1 under IGN1 ON && Alt L ON. But ALL
DOOR LOCK , All DOOR LOCK signal is not
output if all DOOR is LOCK or ALL DOOR are
FAIL. |
| 2. |
LOCK signal is output 3 times as Max if
either one DOOR is UNLOCK after LOCK signal output in (2).(1s cycle)
But, DOOR, which is LOCK from UNLOCK state during 3-time output, is
ignored. |
| 3. |
Relevant DOOR is FAIL if the state is
UNLOCK after 3-time output. |
| 4. |
LOCK signal is output once if the FAIL DOOR
is UNLOCK again after the DOOR is
LOCK. |
| 5. |
LOCK signal is output once if locked doors,
which are LOCK state after LOCK signal output in (2), are unlocked
again. But, LOCK signal is output once for the relevant DOOR even
when UNLOCK state continues after LOCK signal
output. |
| 6. |
FAIL DOOR is cleared at IGN switch
OFF. |
| 7. |
AUTO DOOR LOCK function is not performed
when CRASH UNLOCK condition is met. |
| 8. |
AUTO DOOR LOCK function is not performed
when set up L_SIDE AIR OPT = ON.

T1 : max 1.5sec, T2 : 0.5 ±
0.1sec
ANY DOOR UNLOCK ON driver Unlock State
Unlock or assist Unlock State Unlock or rear left Unlock State or
rear right unlock state
ANY DOOR UNLOCK OFF driver Unlock State Lock
assist Unlock State Lock and rear left Unlock State and rear right
unlock state |
Auto
Door Lock By Shift Lever Change
| 1. |
IGN1 ON & Alt L ON state of 100msec in
the close future, and ANY DOOR UNLOCK ANY
DOOR UNLOCK ALL DOOR (Driver door SW & Assist door SW & Rear
left door SW & Rear right SW) in the conditions when Inhibit P,
ON->OFF, ALL DOOR LOCK to the
output. |
| 2. |
AUTO DOOR LOCK function is not performed
when CRASH UNLOCK condition is met. |
Auto
Door Unlock By Key In Condition
| 1. |
ALL DOOR UNLOCK signal is output at IGN KEY
IN→OUT. But, UNLOCK state that is ALL DOOR to UNLOCK does not
output.

T1 : 0.5 ± 0.1sec
*1 ON(UNLOCK) : Driver Unlock State or
assist Unlock State or rear left Unlock state or rear right unlock
state = UNLOCK
OFF (LOCK) : Driver Unlock State &
assist Unlock State & rear left Unlock state & rear right
unlock state = LOCK
*2 KEY IN ON : Key in switch ON or ACC =1 or
IGN1 ON or IGN2 ON
KEY IN OFF : Key in switch OFF and ACC =0
and IGN1 OFF and IGN2 OFF |
Auto
Door Unlock (Only SMK)
| 1. |
Under under ANY DOOR LOCK, ALL DOOR UNLOCK
signal is output at ACC ON→OFF.

T1:0.5s ±
0.1s |
Auto
Door Unlock By Driver Door Unlock State (User Option)
| 1. |
In Lock states of ANY DOOR (C_DRVUnlockState
|| C_ASTUnlockState || C_RLUnlockState || C_RRUnlockState), if
C_DRVUnlockState is LOCK → UNLOCK, ALL DOOR UNLOCK is output one
time for T1 .

T1:0.5s
±0.1s |
Auto
Door Unlock By Shift Lever Change
| 1. |
ALL DOOR CLOSE & ANY DOOR LOCK state is
the state of IGN1 & Alt L ON to OFF->ON when in Inhibit P
after 300msec, CENTRAL DOOR UNLOCK is the
output. |
Trunk
Release Relay Control
| Trunk Release
Relay Control Data Flow |

Trunk
Release Relay Control
| 1. |
If TXTrunk is received, C_TGReleaseRly is ON
for T1. (Non-SMK)
If C_SMKRKECMD Trunk signal is received,
C_TGReleaseRly is ON for T1. (SMK) |
| 2. |
Trunk control by TGReleaseRly SW is
mechanical operation.

T1 : 500 ±
100msec |
ATM
Shift lock control(AT)

| 1. |
In L_IGN1 ON, C_InhibitP ON or C_InhibitN ON
condition, if L_BrakeSW input is ON, O_ATMSOL output is ON to makes
moving condition of SHIFT LEVER. |
| 2. |
In L_IGN1 ON, vehicle speed is less than
7KPH and C_InhibitD ON conditions, if L_BrakeSW input is ON,
O_ATMSOL output is ON to makes moving condition of SHIFT
LEVER.

|
Key
Interlock Control

| 1. |
Key solenoid to the output of the ON KEY to
make the subject does not fall. (If IGN1 ON or ACC subject to the
key Interlock switch input is OFF.) |
| 2. |
In addition to the above conditions, the KEY
OFF key solenoid output to fall out, to make
conditions. |
| 3. |
Key solenoid output OFF -> ON operation,
0.9sec ~ 1.5sec for the 7 - 10V and the behavior, then the voltage 6
- 9V to maintain.

T1 : 0.9 ~
1.5sec |
Tail
Lamp Function In/out
| Tail Lamp
Function Block Diagram |

Tail lamp function In/Out
List
Function
|
Characteristics
|
Name
|
Hardware
Label
|
Spec.
Designation
|
Input
|
Logic
|
L_IGN1
|
IGN1
|
L_KeyIn
|
Key In
Signal
|
L_IGN2
|
IGN2
|
L_ACC
|
ACC
|
L_TailSW
|
Tail Lamp
Switch
|
L_AutolightSW
|
Autolight
Switch
|
Internal
|
b_TailAutoState
|
Tail Lamp On/Off Request
by Auto Light Control Module
|
b_Escort
|
Escort
activation/deactivation Status
|
CAN
Communication
|
C_DRVDRSW
|
Driver Side Door
Switch
|
Internal
|
b_KeyInMarker
|
Key Inserted state
Marker
|
b_TailAutoCut
|
Auto Cut Status
(Memorized in EEPROM)
|
b_TailLampSWOn
|
On:
|
L_TailSW = On ||
(b_TailAutoState = On &(b_IGN = On || b_START =
On))
|
Off:
|
L_TailSW = Off &
(b_TailAutoState = Off || (b_TailAutoState = On & b_IGN =
Off & b_START =Off))
|
b_DDSWMarker
|
Driver door opened during
escort state marker
|
Output
|
Internal
|
TailOn
|
On : C_EXTTailON==On
&& C_INTTailON==On
|
Off : C_EXTTailON==Off
&& C_INTTailON==Off
|
CAN
Communication
|
C_EXTTailON
|
Tail Lamp On/Off
command
|
C_INTTailON
|
Interior Tail Lamp On/Off
command
|
Function
Description
| •
|
General Function Condition
In BATTERY ON and Tail Lamp is off state, if
user turns on the Tail Lamp switch (Tail switch ON), Tail Lamps are
turned on. |
| 1. |
Tail Auto Cut Function
Condition
The “Tail Auto Cut” strategy ensures that
Tail lamps are turned off even if a driver forgets to turn them off.
When the Tail lamp is turned on by Tail lamp switch, after key
insertion , and if a user removes key and opens the driver side
door(or vice versa), the Tail lamps are automatically turned off.
While “Tail Auto Cut” function is active, if a user turns off the
Tail lamp switch or inserts key, “Tail Auto Cut” function will be
deactivated and Tail lamps can be turned on.
| - |
“Tail Auto Cut” state is
memorized in ECU, so even if battery reset, this state
is not erased. |
| - |
During the activation of Escort
function, no Tail Auto Cut mode is possible and it is
only after escort function deactivation that Tail Auto
Cut mode can be applied.
| |
| (1) |
CAN signal Tail Activity
Condition
When tail lamp output condition is
met, Tail Lamp activity CAN data (EXT Tail_Act & INT Tail
Act) is also turned on. When tail lamp output condition is not
met, Tail Lamp activity CAN data (EXT Tail Act & INT Tail
Act) is also turned off. |
| (2) |
Internal signal Tail Activity
Condition
When tail lamp output is on, internal
signal Tail Lamp activity (Tail Lamp) is also turned on.When
tail lamp output is off, internal signal Tail Lamp activity
(Tail Lamp) is also turned off.

| |
| 2. |
HEAD LAMP CONTROL
| (1) |
Overview Description
This function describes the following
features
| A. |
Turn on and off Head Lamp Low by
Head Lamp Low Switch
input. |
| B. |
Turn on and off Head Lamp Low by
Escort Function. |
| C. |
Turn on and off Head Lamp Low by
Auto Light Control
Request. |
| D. |
Turn on and off Head Lamp High
by Head Lamp High Switch
input. |
| E. |
Turn on and off Head Lamp High
and Low by Passing Switch
Input. |
| F. |
Output control of Head Lamp
Low. |
| G. |
Output control of Head Lamp
High. |
| H. |
Output control of Head Lamp High
Indicator. |
| I. |
Output control of Head Lamp
control for CANADA
DRL. | | |
Head
Lamp Function IN/OUT
| 1. |
Head Lamp Function Block
diagram

Head Lamp Function In/Out List
Function
|
Characteristics
|
Name
|
Hardware
Label
|
Spec.
Designation
|
Input
|
Digital
|
L_HeadLampLowSW
|
Head Lamp Low
Switch
|
L_AutoLightSW
|
Auto Light
Switch
|
L_HeadLampHighSW
|
Head Lamp High
Switch
|
L_IGN1
|
Ignition1
power
|
L_EC_DRL_OPT
|
Dedicated DRL
option Switch
|
CAN Communication
|
C_ALT_L
|
Engine is
running
|
C_SMKRKECMD
|
SMK RKE Command
from Fob
|
C_DRVDRSW
|
Driver Side Door
Open/Close Status
|
C_PARKING BRAKE
SW
|
Parking Brake
Switch Status
|
C_CANADA_DRLSts
|
DRL Option
Switch
|
C_D_DRL_Act
|
Dedicated DRL
ON/Off State
|
C_HLampLOW_Act
|
Head Lamp Low
On/Off State
|
C_HLampHIGH_Act
|
Head Lamp High
On/Off State
|
Internal
|
b_HeadAutoState
|
Head Lamp Low
On/Off request by Auto Light Control Module
|
Internal
|
b_KeyOff
|
L_KeyIn == Off
&& L_ACC == Off && L_IGN1 == Off &&
L_IGN2 == Off
|
b_C_IGNSW
|
Same value with
C_IGNSW(refer ECU spec.)
|
b_IGN
|
on : b_C_IGNSW ==
IGN ON off : b_C_IGNSW == KEY OFF
|| b_C_IGNSW == KEY IN ||
b_C_IGNSW ==ACC ON || b_C_IGNSW ==ST
|
b_ACC
|
on : b_C_IGNSW ==
ACC ON off : b_C_IGNSW == KEY OFF
|| b_C_IGNSW == KEY IN ||
b_C_IGNSW ==IGN ON || b_C_IGNSW ==ST
|
b_START
|
on : b_C_IGNSW ==
ST off : b_C_IGNSW == KEY OFF ||
b_C_IGNSW == KEY IN ||
b_C_IGNSW ==ACC || b_C_IGNSW ==IGN ON
|
b_HeadLampHighSW
|
This signal
reserved for separated Head Lamp High input from Passing
input
|
b_PassingSW
|
On:L_HeadLampHighSW==OnOff:L_HeadLampHighSW==Off
|
b_HeadLampLowSWOn
|
On: L_HeadLampLowSW
== On || (b_HeadAutoState == On
&& (b_IGN == On ||
b_START == On)) Off:
L_HeadLampLowSW == Off && b_HeadAutoState == Off
|
b_LOCK
|
P_RKECMD == Lock ||
C_SMKRKECMD == Lock || C_PassiveLock == Lock
|
b_2LOCK
|
b_LOCK
counter
|
b_Unlock
|
b_RKEUnLock==On || C_SMKRKECMD == UnLock ||
C_PassiveUnlock== UnLock
|
b_DRLOpt
|
DRL Option
|
Output
|
Digital
|
O_HeadLampLowCTRL
|
Head Lamp Low
Output Status (Active Low)
|
Internal
|
b_Escort
|
Escort
activation/deactivation Status
|
b_HeadLampHighOutput
|
On:
C_HeadLampHighON = OnOff: C_HeadLampHighON =
Off
|
b_HeadLampLow
|
Internal Head Lamp
Low activity
|
b_HeadLampHigh
|
Internal Head Lamp
High activity
|
b_DRLOut
|
DRL Option
activation/deactivation Status
|
CAN Communication
|
C_CANADA_DRLON
|
CANADA DRL ON
Command
|
C_D_DRL_ON
|
DEDICATED DRL ON
Command
|
C_HeadLampLowON
|
Head Lamp Low
On/Off command
|
C_HeadLampHighON
|
Head Lamp High
On/Off command
|
C_EXTTailON
|
EXTTail On/Off
command
|
|
| 2. |
Head lamp low signal control
| A. |
Head Lamp Low control output is ON if
HEAD LAMP LOW output is ON by ‘Head Lamp Low switch ON ‘ or
‘AUTO LIGHT function’. |
| B. |
Head Lamp Low control output is OFF
when HEAD LAMP LOW output is
ON->OFF. | |
| 3. |
Head lamp high control
Head Lamp High input and Head Lamp Passing
input by M/F is Head Lamp High switch processing for single input
same MULTI-FUNCTION WIRING DESCRIPTION as Head Lamp High switch only
input.
| A. |
Head Lamp High Input
When Head Lamp High switch ON that in
IGN2 ON and Head Lamp Low control output is ON by IMP, Head
Lamp High is consider as input.
|
| B. |
Head Lamp Passing Input
When Head Lamp High switch ON that in
IGN2 ON and Head Lamp Low control output is OFF, Head Lamp
Passing is consider as
input. | |
| 4. |
Multi-function wiring
description

|
Function
Description
| 1. |
Head Lamp Low Control
In IGN terminal State (IGN ON), if turn on
the Head Lamp LOW switch(Head Lamp Low switch ON),
Head Lamp LOW outputs are turned on (Head
Lamp Low ON).
When Tail lamp Off and headlamp Off
conditions are satisfied at the same time, Head Lamp LOW and Tail
LAMP turned off simultaneous
immediately. |
| 2. |
Head Lamp High Control
In IGN terminal State(IGN ON) and Head Lamp
Low switch On(Head Lamp Low switch ON), if turn on the Head Lamp
High switch(Head Lamp High switch ON), Head Lamp High Outputs are
turned on (Head Lamp High ON). |
| 3. |
Passing Control
In IGN terminal State(IGN ON), If Head Lamp
Passing switch Input(Head Lamp High switch ON & Head Lamp Low
control OFF) is detected then Head Lamp High Output(Head Lamp High
ON) are turned on and Head Lamp Low Output(Head Lamp Low ON) at the
same time. |
| 4. |
Canada DRL
| A. |
If alternator level is high(ALT L=On),
BCM activates Canada DRL functionality and turns on the Head
lamp high (CANADA DRL=On). |
| (1) |
Head lamp low On request by Head lamp
switch or auto light head lamp Low control
or |
| (2) |
Head high On request by passing switch
or |
| (3) |
Parking brake switch On

| |
| 5. |
Escort Function
After user generates the call of head lamp
low light(Head Lamp Low switch On), if switch off ignition(IGN Off
and START Off), and then keep Head Lamp Low Output On (Head Lamp Low
ON)state during 20min.
And after open and close driver side
door(Driver door switch ON -> Driver door switch Off), user will
have consequently lighting of head lamp low(Head Lamp Low ON) during
only 30sec.
During active “Escort Function”, if receive
Lock request 2 times (2 LOCK) or cancel the lighting request of head
lamp low (Head Lamp Low switch Off & Auto Light switch Off),
this function is released.
Lock request counting for 2 times (2 LOCK)
is each follow cases:
| (3) |
Passive Access Lock==
Lock
If open the Driver door(Driver door
switch ON) or close(Driver door switch Off), former lock
counter is cleared, and start new 2 times lock
counting. | |
| 6. |
Head Lamp Welcome Function
"Multifunction switch head lamp or auto
light position and lock stated, if remote unlock, and then keep head
lamp output on state during 15second.Lighting state, if remote lock
and unlock, immediately light turn off."
| - |
While escort function is
activated, Tail lamp is keeping the turn on state and
does not go to Auto cut and after finish escort state
and user removes key, it can go Auto cut
mode. |
| - |
While the “Escort Function” is
activated by ‘Head Lamp Low Switch’, if change from
‘Head Lamp Low Switch’ to ‘Lamp Auto Switch’, “Escort
Function” is deactivated, because Lamp Auto mode is
‘Lamp Off’ condition.
|
| - |
While the “Escort Function” is
activated by ‘Lamp Auto Switch’, if change from ‘Lamp
Auto Switch’ to ‘Head Lamp Low Switch’, “Escort
Function” is keeping the activation state, because of
‘Head Lamp On’
condition. |
| - |
After IGN terminal off 20 minute
timers is started, but as soon as door is opened and
closed then 30sec timer is engaged.

| | |
Auto
Light Control
| 1. |
Overview Description
This function describes the following
features.
| A. |
Input detection by Auto Light
Sensor. |
| B. |
Generate Auto Light Out Status
data. |
| C. |
Send Auto Light Out
Status. |
| D. |
Tail Lamp Control by Auto light
Mode. |
| E. |
Head Lamp Low Control by Auto light
Mode. |
| F. |
AV Tail Control by Auto Light sensor
level.
Auto Light Mode State Diagram is based
on Auto Light Sensor's level.
Power condition of Auto Light
Action. |
| G. |
When CAN Wake-up, ACC, IGN, START
terminal states, Auto Light Sensor
operates. |
Variant
Tail
lamp
|
ON
|
1.32 ± 0.1
V
|
OFF
|
3.24 ± 0.2
V
|
Head
lamp
|
ON
|
1.32 ± 0.1
V
|
OFF
|
3.24 ± 0.2
V
|
Filtering
time
|
ON
|
2.5 ± 0.1
Sec.
|
OFF
|
2.5 ± 0.1
Sec.
|
|
Auto
Light Control Function In/out
| 1. |
Auto Light Control Function Block
Diagram

Auto Light Control Function In/Out list
Function
|
Characteristics
|
Name
|
Hardware
Label
|
Spec.
Designation
|
Input
|
Logic
|
L_AutolightSW
|
Auto Light
Switch
|
Analog
|
A_AutoLightSnsr
|
Auto Light Sensor
Level
|
Output
|
Internal
|
b_TailAutoState
|
Tail Lamp On/Off
Request by Auto Light Control Module
|
b_HeadAutoState
|
Head Lamp Low
On/Off Request by Auto Light Control Module
|
Logic
|
V_AutoLightGND
|
Supplying Ground to
Auto Light Module
|
V_AutoLightPwr
|
Supplying Power to
Auto Light Module
|
O_AVTail
|
AV Tail
output
|
CAN
Communication
|
C_AV_Tail
|
Auto Light output
to AV module
|
In Export Version,
Tail Lamp, Head Lamp Low Control

AV tail
control

| 1. |
During above ON/Off Filtering
times, if a detected sensor value doesn’t satisfy the
ON/Off condition, filtering time counter is cancelled.
When Tail lamp Off and Headlamp Off conditions are
satisfied at the same time, Head Lamp Low and Tail Lamp
are turned off
simultaneous. |
| 2. |
These Filtering value is
calibration value so it’s
changeable. |
| 3. |
In ACC terminal state, Tail Lamp
and Head Lamp Low filtering times are not used; AV Tail
Out filtering time is used even in ACC terminal state.
|
| 4. |
These filtering times shall have
an error tolerance of
+/-100msec | |
Continuous Turn ON Mode
CASE(1) : At the time that Tail Lamp and
Head Lamp Low switch position are changed from manual ON to Auto ON
position, if intensity of light measured by Auto light sensor that
is already calculated satisfies the Head Lamp Low ON condition, Head
Lamp Low is turned ON continuously without fluctuation
CASE(2) : In the hysteresis range between
level On and level Off, the current state of Lamp is
kept.
CASE(3) : As soon as the MFSW is changed to
Off position, the lamp is turned Off immediately (Without Off delay
times.)
|
Only in the terminal states of IGN and
START, the Auto Light control functions of Tail lamp and head
Lamp Low outputs can be
active. |

|
Front
Fog Lamp Control
| 1. |
Overview Description
This function describes the following
features
| A. |
Turn on and off Front Fog Lamp by
Front Fog Lamp switch input. |
| B. |
Versus variant (NA, Non-NA), function
description | |
Front
Fog Lamp Function In/out
| 1. |
Front Fog Lamp Function Block Diagram

Front Fog Lamp Function In/Out List
Function
|
Characteristics
|
Name
|
Hardware
Label
|
Spec.
Designation
|
Input
|
Logic
|
L_IGN2
|
ignition
2
|
L_FrontFogSW
|
Front Fog Switch
Input
|
Internal
|
b_TailLamp
|
Tail Lamp Output
activation state
|
b_HeadLampLow
|
Head lamp low
Output activation state
|
b_HeadLampHigh
|
Head lamp high
Output activation state
|
Output
|
CAN
Communication
|
C_FrontFogON
|
Front Fog Lamp
Output
|
Internal
|
b_FrontFogLamp
|
Front Fog Lamp
Output activation
state
|
|
| 2. |
Function Description
| (1) |
In case of (IGN2=ON) &
(HeadLampLow=ON) & (HeadLampHigh=Off), if Front fog lamp
switch input is detected (FrontFogSW=On), Front fog lamp
output (FrontFogON=On) is turned
ON. |
| (2) |
If fails to activate front fog lamp
output, indicator (FrontFogIND) is also turn off.

| | |