| 2. |
Disconnect the connector of mode control
actuator. |
| 3. |
Verify that the mode control actuator
operates to the defrost mode when connecting 12V to the terminal
3and grounding terminal 7. |
| 4. |
Verify that the mode control actuator
operates to the vent mode when connecting in the
reverse

1.
- 2. - 3.
Defrost mode 4.
5V(Vcc)
|
5. Feedback
signal 6. Sensor
ground 7. Vent
mode
|
|
| 5. |
Check the voltage between terminals 5 and
6.
Door
position
|
Voltage
(5-6)
|
Error
detecting
|
Close
|
0.3 ±
0.15V
|
Low voltage :0.1V
or less
|
Open
|
4.7 ±
0.15V
|
High voltage :4.9V
or more
|
It will feedback current position of
actuator to controls. |
| 6. |
If the measured voltage is not
specification, substitute with a known-good mode control actuator
and check for proper operation. |
| 7. |
If the problem is corrected, replace the
mode control actuator. |
| 1. |
Remove the side cover (A).

|
| 2. |
Loosen the mounting nut and clip remove the
extension cover (A).

|
| 3. |
Disconnect the guide (B), from the glove box
(C) and then remove the glove box left (A).

|
| 4. |
Disconnect the pin (A) and then remove the
glove box (B).

|
| 5. |
Loosen the mounting screw, and then remove
the crash pad panel (A).

|
| 6. |
Loosen the mounting bolts and screws and
then remove the glove box housing (A).

|
| 7. |
Remove the shower duct (A).

|
| 8. |
Disconnect the auto defogging actuator
connector (A). |
| 9. |
Loosen the mounting screw and then remove
the auto defogging actuator (B).

|
| 10. |
Installation is the reverse order of
removal. | |