Home › Emission Control System › Evaporative Emission Control System › Canister

Evaporative Emission Control System › Canister: Repair procedures

Removal
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the ventilation hose (A), and then remove the bracket mountiong bolt (B).

3.
Disconnect the vapor tube quick-connector (A), and then remove the mounting nuts (B).

4.
Remove the canister assembly after removing mounting bolts (B) and ventilation hose (A).

[Auxiliary Canister (SULEV Only)]
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the vapor hose (A) and ventilation hose (B).
3.
Remove the auxiliary canister (C) after removing the nuts.

Inspection
1.
Check for the following items visually.
- Cracks or leakage of the canister
- Loose connection, distortion, or damage of the vapor hose/tube

A: Canister ↔ Atmosphere
B: Canister ↔ Intake Manifold
C: Canister ↔ Fuel Tank
Installation
Installation is the reverse of removal.

Canister installation bolt/nut:
19.6 ~ 29.4 N.m (2.0 ~ 3.0 kgf.m, 14.5 ~ 21.7 lb-ft)