| 6. |
Install the new bottom cap to the
condenser.
| •
|
Always replace the desiccant and
bottom cap at the same
time. |
| •
|
Replace the O-rings with new ones
at each fitting, and apply a thin coat of refrigerant
oil before installing them. Be sure to use the right
O-rings for R-134a to avoid
leakage. |
| •
|
Be careful not to damage the
radiator and condenser fins when installing the
condenser. |
| •
|
Be sure to install the lower mount
cushions of condenser securely into the
holes. | |
| •
|
Charge the system, and test its
performance. | | |