Home › Heating,Ventilation, Air Conditioning › Blower › Intake Actuator

Blower › Intake Actuator: Repair procedures

Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the intake actuator connector.
3.
Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 4 and grounding terminal 3.
Verify that the intake actuator operates to the recirculation position when connected in reverse.

1. -                 
2. -                  
3. Fresh
4. Sensor (+ 5V)
5. Feedback Signal
6. Sensor Ground
7. Recirculation

4.
Connect the intake actuator connector.
5.
Turn the ignition switch ON.
6.
Check the voltage between terminal 6 and 5.
Specification
Door position
Voltage (V)
Fresh
0.3
Recirculation
4.7

7.
If the intake actuator does not operate well, substitute with a known-good intake actuator and check for proper operation.
8.
If the problem is corrected, replace the intake actuator.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the main crash pad assembly.
3.
Disconnect the connector and then remove the intake actuator (A) after loosening the mounting screws.

4.