Home › Heating,Ventilation, Air Conditioning › Controller › Heater & A/C Control Unit (DATC)

Controller › Heater & A/C Control Unit (DATC): Repair procedures

Self Diagnosis
1.
Self-diagnosis process

2.
How to read self-diagnostic code
After the display the panel blinks three times every 0.5 second, the corresponding fault code blinks on the setup temperature display panel every 0.5 second and will show two figures. Codes are displayed in numerical format
Fault codes are displayed in numerical format.
Display
Fail description
0
Normal
11
In-car sensor open
12
In-car sensor short
13
Ambient temperature sensor open
14
Ambient temperature sensor short
17
Evaporator temperature sensor open
18
Evaporator temperature sensor short
19
Temperature door potentiometer open/short (Driver)
20
Temperature door potentiometer fault (Driver)
21
Mode door potentiometer open/short
22
Mode door potentiometer fault
23
Auto defogging sensor open
24
Auto defogging sensor short
25
Intake door potentiometer open/short
26
Intake door potentiometer fault
32
Temperature door potentiometer open/short (Passenger)
33
Temperature door potentiometer fault (Passenger)
45
APT (A/C Pressure Transducer) CAN signal fault
47
RPM CAN signal fault
48
Vehicle speed CAN signal fault
49
Engine coolant temperature CAN signal fault
50
Cluster ionizer fault

3.
Fault code display
(1)
Continuance operation : None or one DTC code.

(2)
Continuance operation : Two or more DTC code.

(3)
STEP operation
A.
Normal or one fault code is same as a continuance operation.
B.
There are two or more DTC code.

4.
If fault codes are displayed when checking, inspect for malfunction causes by referring to fault codes table.
5.
Fail safe
(1)
In-car temperature sensor : Control with the value of 25°C(77°F)
(2)
Ambient temperature sensor : Control with the value of 20°C(67°F)
(3)
Evaporator temperature sensor : Control with the value of -2°C(28.4°F)
(4)
Water temperature sensor : Control with the value of 90°C(194°F)
(5)
Temperature control actuator (Air mix potentiometer) :
If temperature setting is 17°C-24.5°C, fix at maximum cooling position.
If temperature setting is 25°C-32°C, fix at maximum heating position.
(6)
Mode control actuator (Direction potentiometer) :
Fix vent position, while selecting vent mode.
Fix defrost position, while selecting all except vent mode.
(7)
Intake control actuator :
Fix fresh position, while selecting fresh mode.
Fix recirculation position, while selecting recirculation mode.
(8)
Auto defog sensor : Control with the value of 0%.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Using a screwdriver or remover, remove the crash pad center garnish (A).

3.
Remove the heater and A/C controller (A) after loosening 4 screws.

4.
Disconnect the connectors (A).

5.
Install in the reverse order of removal.