Signal Circuit Inspection
| 1. |
Check ignition lock switch pull-up
voltage
| (1) |
IG KEY "OFF", ENGINE "OFF".
|
| (2) |
Disconnect ignition lock switch
connector. |
| (4) |
Measure the voltage between signal
terminal of ignition lock switch harness connector and chassis
ground.
Specification : 11.5V
~ 13.0V
| | |
| 2. |
Check open in ignition lock switch signal
circuit
| (1) |
IG KEY "OFF", ENGINE "OFF".
|
| (2) |
Disconnect ignition lock switch
connector and ECM connector. |
| (3) |
Check continuity between signal terminal
of lock switch signal harness connector and ECM harness
connector.
Specification :
Continuity ( below 1.0Ω )
|
| |
Ground Circuit inspection
| 1. |
IG KEY "OFF", ENGINE "OFF".
|
| 2. |
Disconnect ignition lock switch connector.
|
| 3. |
Check continuity between lock switch signal
connector terminal 1 and chassis ground.
Specification
: Continuity ( below 1.0Ω
)
|
|
Component Inspection
| 1. |
Remove the ignition lock
switch. |
| 2. |
Push the ignition lock switch in the direction
of the arrow to make sure that continuity between terminals. (refer
to the table below)
Standard value
:
Full stroke (A): 12.0 ± 0.3mm (0.4724 ±
0.0118 in.)
ON-OFF point (B): 2.0 mm(0.0787
in.)
|

|
Condition
|
Clutch Pedal
pressed
|
Clutch Pedal
Released
|
Switch Operation
|
ON (below 1.0Ω )
|
OFF ( Infinite Ω
)
|
| |
| 1. |
Turn ignition switch OFF and disconnect the
negative (-) battery cable. |
| 2. |
Disconnect ignition lock switch connector (A).

|
| 3. |
Remove the ignition lock switch by loosening a
nut (A).

|
| 1. |
Installation is the reverse of removal.
|
| 2. |
Adjust the ignition switch.
| (1) |
In state of full stroke, adjust the gab
by rotating the adjust nut (A) to satisfy the standard gap
range.
Standard
gap range :
3 ~ 4 mm (0.1181 ~ 0.1575
in.)
| |
| (2) |
Tighten the nut (B) with the specified
torque.
Tightening torque:
7.8 ~ 9.8 N (0.8 ~ 1.0 kgf.m, 5.8
~ 7.2 lb-ft)
| |

|