Home
›
Engine Mechanical System
›
Intake And Exhaust System
›
Variable Intake Solenoid(VIS) Actuator
Intake And Exhaust System › Variable Intake Solenoid(VIS) Actuator: Repair procedures
Removal and Installation
1.
Disconnect the vacuum hose (A).
2.
Remove the variable Intake solenoid (VIS) actuator (B)
Tightening torque :
9.8 ~ 11.8N.m (1.0 ~ 1.2kgf.m, 7.2 ~ 8.7lb-ft)
3.
Install in the reverse order of removal.