Home › Engine Mechanical System › Intake And Exhaust System › Muffler

Intake And Exhaust System › Muffler: Repair procedures

Removal and Installation
[Front muffler]
1.
Disconnect the front oxygen sensor connector (A) and then remove it from the bracket. (ULEV only)

2.
Remove the front muffler (A).

Tightening torque :
39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ~ 43.4 lb-ft)

3.
Install in the reverse order of removal.
When installing, replace with new gaskets.
[Center muffler]
1.
Disconnect the bracket (A) and then remove the rear oxygen sensor (B).

Tightening torque
Oxygen sensor :
39.2 ~ 49.0 N.m (4.0 ~ 5.0 kgf.m, 28.9 ~ 36.2 lb-ft)

2.
Remove the catalytic converter and center muffler assembly (A).

Tightening torque :
39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ~ 43.4 lb-ft)

3.
Install in the reverse order of removal.
When installing, replace with new gaskets.
[Main muffler]
1.
Remove the main muffler (A).

Tightening torque :
39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ~ 43.4 lb-ft)

2.
Install in the reverse order of removal.
When installing, replace with new gaskets.