Home › Emission Control System › Crankcase Emission Control System › Positive Crankcase Ventilation (PCV) Valve

Crankcase Emission Control System › Positive Crankcase Ventilation (PCV) Valve: Repair procedures

Removal
1.
Disconnect the vapor hose (A).
2.
Remove the PCV valve (B).

Inspection
1.
Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that the plunger movement.

•
If the plunger does not move (PCV valve is clogged), clean or replace the valve.
Installation
1.
Installation is reverse of removal.

PCV Valve installation:
1.96 ~ 2.94 N.m (0.2 ~ 0.3 kgf.m, 1.45 ~ 2.17 lb-ft)