Home › Heating,Ventilation, Air Conditioning › Air conditioning System › A/C pressure transducer

Air conditioning System › A/C pressure transducer: Repair procedures

INSPECTION
1.
Measure the pressure of high pressure line by measuring voltage output between NO.1 and NO.2 terminals.

2.
Verify that the voltage value is within specification.

Voltage = 0.025 * Pressure + 0.1 [kgf/cm²]
Voltage = 0.001758 * Pressure + 0.074162 [PSIA]

3.
If the measured voltage value is not specification, replace the A/C pressure transducer.
REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
Verify that the voltage value is within specification.
3.
Disconnect A/C pressure transducer connector (3P) (A).