Power Door Locks › Power Door Lock Relay: Repair procedures
INSPECTION
1.
Disconnect the negative (-) battery
terminal.
2.
Remove the junction
box.
3.
Check for continuity between the
terminals.
DOOR
LOCK
1.
There should be continuity between the No.5
in the I/P-J and No.18 terminals in the I/P-D when power and ground
are connected to the No.2 terminal in the I/P-C and No.9 terminal in
the I/P-J.
2.
There should be no continuity between the
No.5 terminal in the I/P-J and No.18 terminal in the I/P-D when
power is disconnected.
DOOR
UNLOCK
1.
There should be continuity between the No.5
terminal in the I/P-J and No.7 terminal in the I/P-K when power and
ground are connected to the No.2 terminal in the I/P-C and No.1
terminal in the I/P-K.
2.
There should be no continuity between the
No.5 terminal in the I/P-J and No.7 terminal in the I/P-D when power
is disconnected.