BURGLAR
ALARM SYSTEM
The burglar alarm
system is armed automatically after the doors, hood, and tailgate are
closed and locked.
The system is set off
when any of these things occur :
| •
|
The tailgate is opened without using the
key. |
When the system is set
off, the alarm sounds and the hazard lamp flash for about 30 seconds or
until the system is disarmed by unlocking the transmitter.
For the system to arm,
the ignition switch must be off and the key removed. Then, the body
control module must receive signals that the doors, hood, and tailgate are
closed and locked. When everything is closed and locked, none of the
control unit inputs are grounded.
The door switches,
hood switch and tailgate switch are all close and lock the doors with the
remote transmitter and then the system arms immediately.
If anything is opened
after the system is armed, the body control module gets a ground signal
from that switch, and the system is set off.
If one of the switches
is misadjusted or there is a short in the system, the system will not arm.
As long as the body control module continues to get a ground signal, it
thinks the vehicle is not closed and locked and will not arm.
KEYLESS
ENTRY SYSTEM
The burglar alarm
system is integrated with the keyless entry system. The keyless entry
system allows you to lock and unlock the vehicle with the remote
transmitter. When you push the LOCK button, all doors lock. When you push
the UNLOCK button again, all doors unlock.
The room lamp, if its
switch is in the center position, will come on when you press the UNLOCK
button. If you do not open a door, the light will go off in about 30
seconds, the doors will automatically relock, and the burglar alarm system
will rearm. If you relock the doors with the remote transmitter within 30
seconds, the light will go off immediately.
You cannot lock or
unlock the doors with the remote transmitter if the key is in the ignition
switch.
The system will signal
you when the doors lock and unlock by flashing the hazard lamp once when
they lock, and twice when they unlock.
| ANTI-THEFT WARNING
SYSTEM |

| 1. |
SECURITY LED CONTROL
| (1) |
If the KEY IN is ON or ACC is ON or
IGN1 is ON or IGN2 is ON, the LED shall be
OFF. |
| (2) |
When entered into the ARM WAIT mode in
the IGN KEY OUT state, control not only the FULL ON but also
the BLINKING in the mode other than the ARM
WAIT. |
| (3) |
The BLINKING cycle is 2.3 seconds, and
it is ON for 0.3 seconds and OFF for 2.0 seconds.

T1 : 0.3s, T2 :
2s | |
| 2. |
DISARM
Condition 1
State
|
Description
|
Initial Condition
|
ALARM
|
Transition Condition
|
| - |
When 4DOOR or Tailgate is OPEN
and TX(Transmitter) UNLOCK is
input |
| - |
After 30 seconds in the KEY IN
ON and IGN1 ON and IGN2 ON
states |
| - |
When all doors are unlocked
(LOCK FAIL) within 5 seconds after the TX(Transmitter)
LOCK input | |
Operating
|
| - |
ENTRY INTO THE DISARM
STATE |
| - |
HORN, HAZARD, Burglar alarm
output shall be OFF |
| - |
In the case of the TX UNLOCK
input, the HAZARD LAMP signal is output with the cycle
of the ON/OFF of 0.5 seconds two
times. | |
Condition 2
State
|
Description
|
Initial Condition
|
In the DISARM state and any one of the IGN KEY
OUT & 4DOOR and Tailgate are opened
|
Transition Condition
|
When entering TX UNLOCK
|
Operating
|
| - |
Maintain in the DISARM
state |
| - |
The HAZARD LAMP signal is output
with the ON/OFF cycle of 0.5 seconds two
times. | |
Condition 3
State
|
Description
|
Initial Condition
|
ARM WAIT state
|
Transition Condition
|
| - |
When any one of the 4DOOR, HOOD
or Tailgate is opened. |
| - |
When at least one or more doors
are unlocked. |
| - |
When the DRIVER KEY
UNLOCK(Tailgate KEY UNLOCK) signal is
input | |
Operating
|
| - |
ENTRY INTO THE DISARM
STATE | |
Condition 4
State
|
Description
|
Initial Condition
|
AUTOLOCK TIMER1 state
|
Transition Condition
|
| - |
When any one of the 4DOOR, HOOD
or Tailgate is opened. |
| - |
LOCK FAIL after the LOCK attempt
by the AUTO LOCK. |
| - |
LOCK FAIL after the LOCK attempt
by the TX LOCK. |
| - |
LOCK FAIL after the LOCK attempt
by the DRIVER KEY LOCK(Tailgate KEY
LOCK). | |
Operating
|
| - |
ENTRY INTO THE DISARM
STATE | |
Condition 5
State
|
Description
|
Initial Condition
|
AUTOLOCK TIMER2 state
|
Transition Condition
|
| - |
When any one of the 4DOOR, HOOD
or Tailgate is opened. |
| - |
LOCK FAIL after the LOCK attempt
by the AUTO LOCK. |
| - |
LOCK FAIL after the LOCK attempt
by the TX LOCK. |
| - |
LOCK FAIL after the LOCK attempt
by the DRIVER KEY
LOCK | |
Operating
|
| - |
ENTRY INTO THE DISARM
STATE | |
Condition 6
State
|
Description
|
Initial Condition
|
ARM state
|
Transition Condition
|
| - |
DRIVER KEY UNLOCK(Tailgate KEY
UNLOCK) input. | |
Operating
|
| - |
ENTRY INTO THE DISARM
STATE | |
Condition 7
State
|
Description
|
Initial Condition
|
REARM state
|
Transition Condition
|
| - |
After 30 seconds in the IGN KEY
ON state. |
| - |
LOCK FAIL after the LOCK attempt
by the TX LOCK. |
| - |
LOCK FAIL after the LOCK attempt
by the DRIVER KEY LOCK. |
| - |
When entering DRIVER KEY
UNLOCK. | |
Operating
|
| - |
ENTRY INTO THE DISARM
STATE |
| - |
Burglar alarm RELAY
OFF | |
Condition 8
State
|
Description
|
Initial Condition
|
REARM state
|
Transition Condition
|
| - |
In case of TX UNLOCK INPUT in
the state that any one of the 4DOOR or Tailgate is
opened. |
| - |
In case of the 4DOORor Tailgate
or HOOD is closed and at least one door is
unlocked. | |
Operating
|
| - |
ENTRY INTO THE DISARM
STATE |
| - |
In the case of the TX UNLOCK
INPUT, the HAZARD LAMP signal is output two times with
the ON/OFF cycle of 0.5
seconds. | |
|
| 3. |
ARM
Condition 1
State
|
Description
|
Initial Condition
|
ARM state
|
Transition Condition
|
When entering TX LOCK
|
Operating
|
| - |
The HAZARD LAMP signal is output
for 1s
once. | |
Condition 2
State
|
Description
|
Initial Condition
|
ARM WAIT state
|
Transition Condition
|
After the ARM WAIT TIMER
completion
|
Operating
|
| - |
ENTRY INTO THE ARM
state | |
|
| 4. |
ALARM
Condition 1
State
|
Description
|
Initial Condition
|
ARM state
|
Transition Condition
|
In case of 4DOOR, Tailgate or HOOD is
opened.
|
Operating
|
| - |
ENTRY INTO THE ALARM
state |
| - |
The Burglar alarm RELAY outputs
is ON, and then, inhibit the
start. |
| - |
The Horn alarm shall be output
three times with the cycle consisting of the ON for
27s(±2s) and the OFF for 10s(±1s). (At this time, the
Hazard Lamp signal shall also be output as the Horn
alarm.) | |
Condition 2
State
|
Description
|
Initial Condition
|
REARM state
|
Transition Condition
|
In case of 4DOOR, Tailgate or HOOD is
opened.
|
Operating
|
| - |
ENTRY INTO THE ALARM
state |
| - |
The Horn alarm shall be output
three times with the cycle consisting of the ON for
27s(±2s) and the OFF for 10s(±1s). (At this time, the
Hazard Lamp signal shall also be output as the Horn
alarm.) | |

T1 : 27 ± 2sec, T2 : 0.4 ~ 0.5
sec,
T3 : 10 ±
1sec. |
| 5. |
ARM WAIT
Condition 1
State
|
Description
|
Initial Condition
|
ARM WAIT state
|
Transition Condition
|
When entering TX LOCK
|
Operating
|
| - |
The HAZARD LAMP signal shall be
output for 1s
once. | |
Condition 2
State
|
Description
|
Initial Condition
|
DISARM state & IGN KEY OUT & 4DOOR,
Tailgate and HOOD CLOSE state
|
Transition Condition
|
| - |
In case of LOCK SUCCESS after
the LOCK attempt by the TX
LOCK. |
| - |
In case of LOCK SUCCESS after
the LOCK attempt by the DRIVER KEY LOCK (Tailgate KEY
LOCK) INPUT. |
| - |
In case of 4DOOR, Tailgate, HOOD
OPEN<CLOSE with all doors
locked. | |
Operating
|
| - |
Entry into the ARM WAIT
state |
| - |
The HAZARD LAMP signal shall be
output for 1s once. |
| - |
Start the ARMWAIT
TIMER | |
Condition 3
State
|
Description
|
Initial Condition
|
ALARM state & IGN KEY OUT & 4DOOR,
Tailgate and HOOD CLOSE state
|
Transition Condition
|
| - |
In case of LOCK SUCCESS after
the LOCK attempt by the TX
LOCK. |
| - |
In case of LOCK SUCCESS after
the LOCK attempt by the DRIVER KEY LOCK (Tailgate KEY
LOCK) INPUT. | |
Operating
|
| - |
Entry into the ARM WAIT
state |
| - |
OFF the HORN, Burglar alarm
output. |
| - |
The HAZARD LAMP signal shall be
output for 1s once |
| - |
Start the ARMWAIT
TIMER | |
Condition 4
State
|
Description
|
Initial Condition
|
AUTOLOCK TIMER1 state
|
Transition Condition
|
| - |
In case of LOCK SUCCESS after
the LOCK attempt by the
AUTOLOCK. |
| - |
In case of LOCK SUCCESS after
the LOCK attempt by the TX
LOCK. |
| - |
In case of LOCK SUCCESS after
the LOCK attempt by the DRIVER KEY LOCK (Tailgate KEY
LOCK) INPUT | |
Operating
|
| - |
Entry into the ARM WAIT
state |
| - |
The HAZARD LAMP signal shall be
output for 1s once. |
| - |
Start the ARMWAIT
TIMER | |
Condition 5
State
|
Description
|
Initial Condition
|
PREARM state
|
Transition Condition
|
| - |
4DOOR, Tailgate and HOOD are
closed and all doors are
locked. | |
Operating
|
| - |
Entry into the ARM WAIT
state |
| - |
The HAZARD LAMP signal shall be
output for 1s once. |
| - |
Start the ARMWAIT
TIMER | |
Condition 6
State
|
Description
|
Initial Condition
|
REARM state
|
Transition Condition
|
| - |
LOCK SUCCESS after the LOCK
attempt by the TX LOCK. |
| - |
LOCK SUCCESS after the LOCK
attempt by the DRIVER KEY LOCK (Tailgate KEY LOCK)
INPUT. | |
Operating
|
| - |
Entry into the ARM WAIT
state |
| - |
The HAZARD LAMP signal shall be
output for 1s once. |
| - |
Start the ARMWAIT
TIMER | |
|
| 6. |
REARM
Condition 1
State
|
Description
|
Initial Condition
|
ALARM state
|
Transition Condition
|
4DOOR, Tailgate and HOOD are closed and after the
ALARM PATTERN completion
|
Operating
|
| - |
Entry into the REARM
state | |
|
| 7. |
AUTO-LOCK TIMER1
Condition 1
State
|
Description
|
Initial Condition
|
ARM state
|
Transition Condition
|
TX UNLOCK INPUT
|
Operating
|
| - |
Entry into the AUTO-LOCK TIMER1
state |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times. |
| - |
START the AUTOLOCK
TIMER1 | |
Condition 2
State
|
Description
|
Initial Condition
|
REARM state
|
Transition Condition
|
| - |
AUTO-LOCK TIMER1
state. |
|
Operating
|
| - |
keep the AUTO-LOCK TIMER1
state |
| - |
CASE1: AUTOLOCK TIMER1
COMPLETION LOCK
ATTEMPT. |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times |
| - |
RESTART THE AUTOLOCK
TIMER1 | |
Condition 3
State
|
Description
|
Initial Condition
|
ARM WAIT state
|
Transition Condition
|
TX UNLOCK INPUT
|
Operating
|
| - |
Entry into the AUTO-LOCK TIMER1
state |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times. |
| - |
START THE AUTOLOCK
TIMER | |
Condition 4
State
|
Description
|
Initial Condition
|
The DISARM state and 4DOOR, Tailgate and HOOD are
closed and IGN KEY OUT
|
Transition Condition
|
TX UNLOCK INPUT
|
Operating
|
| - |
Entry into the AUTO-LOCK TIMER1
STATE |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times. |
| - |
START THE AUTOLOCK
TIMER1 | |
Condition 5
State
|
Description
|
Initial Condition
|
ALARM state, and 4DOOR, Tailgate and HOOD CLOSE
state
|
Transition Condition
|
TX UNLOCK INPUT
|
Operating
|
| - |
Entry into the AUTO-LOCK TIMER1
STATE |
| - |
Burglar alarm RELAY
OFF |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times. |
| - |
START THE AUTOLOCK
TIMER1 | |
Condition 6
State
|
Description
|
Initial Condition
|
REARM state
|
Transition Condition
|
TX UNLOCK INPUT
|
Operating
|
| - |
Entry into the AUTO-LOCK TIMER1
STATE |
| - |
Burglar alarm RELAY
OFF |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times. |
| - |
START THE AUTOLOCK
TIMER1 | |
|
| 8. |
AUTO-LOCK TIMER 2
Condition 1
State
|
Description
|
Initial Condition
|
AUTO-LOCK TIMER2 state
|
Transition Condition
|
| - |
AUTOLOCK TIMER2
COMPLETION. |
|
Operating
|
| - |
keep the AUTO-LOCK TIMER2
state |
| - |
CASE1: AUTOLOCK TIMER1
COMPLETION LOCK
ATTEMPT. |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times |
| - |
RESTART THE AUTOLOCK
TIMER1 | |
Condition 2
State
|
Description
|
Initial Condition
|
REARM state
|
Transition Condition
|
DISARM state AND 4DOOR & Tailgate CLOSE &
HOOD OPEN AND IGN KEY OUT
|
Operating
|
| - |
Entry into the AUTO-LOCK TIMER2
STATE |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times. |
| - |
START THE AUTOLOCK
TIMER2 | |
Condition 3
State
|
Description
|
Initial Condition
|
ALARM STATE AND 4DOOR & Tailgate CLOSE &
HOOD OPEN STATE
|
Transition Condition
|
TX UNLOCK INPUT
|
Operating
|
| - |
Entry into the AUTO-LOCK TIMER2
STATE |
| - |
OFF the HORN, Burglar alarm
OUTPUT |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times. |
| - |
START THE AUTOLOCK
TIMER2 | |
Condition 4
State
|
Description
|
Initial Condition
|
PREARM START AND 4DOOR & Tailgate CLOSE &
HOOD OPEN STATE
|
Transition Condition
|
TX UNLOCK INPUT
|
Operating
|
| - |
Entry into the AUTO-LOCK TIMER2
STATE |
| - |
The HAZARD LAMP signal shall be
output with the ON/OFF cycle of 0.5s two
times. |
| - |
START THE AUTOLOCK
TIMER2 | |
|
| 9. |
PREARM
Condition 1
State
|
Description
|
Initial Condition
|
AUTO-LOCK TIMER2 state
|
Transition Condition
|
| - |
LOCK SUCCESS after the LOCK
attempt by the AUTO
LOCK. |
| - |
LOCK SUCCESS after the LOCK
attempt by the TX LOCK. |
| - |
LOCK SUCCESS after the LOCK
attempt by the DRIVER KEY LOCK (Tailgate KEY LOCK)
INPUT. | |
Operating
|
| - |
Entry into the PREARM
state | |
Condition 2
State
|
Description
|
Initial Condition
|
DISARM state & IGN KEY OUT
|
Transition Condition
|
| - |
LOCK SUCCESS after the LOCK
ATTEMPT by the TX LOCK in the state that 4 DOOR or
Tailgate or HOOD is
opened. |
| - |
LOCK SUCCESS after the LOCK
ATTEMPT by the DRIVER KEY LOCK (Tailgate KEY LOCK) INPUT
in the state that 4 DOOR or Tailgate or HOOD is
opened. |
| - |
The DOOR is turned to the CLOSE
state from the OPEN state in the state that all doors
are locked. But, the HOOD is
opened. | |
Operating
|
| - |
Entry into the PREARM
state | |
Condition 3
State
|
Description
|
Initial Condition
|
ALARM state & IGN KEY OUT & 4DOOR or
Tailgate or HOOD OPEN
|
Transition Condition
|
| - |
LOCK SUCCESS after the LOCK
attempt by the TX LOCK. |
| - |
LOCK SUCCESS after the LOCK
attempt by the DRIVER KEY LOCK (Tailgate KEY LOCK)
INPUT. | |
Operating
|
| - |
Entry into the PREARM
state |
| - |
OFF the HORN, HAZARD, Burglar
alarm
OUTPUT | |
|
| 10. |
RESET
Condition 1
State
|
Description
|
Initial Condition
|
ALARM, REARM state
|
Transition Condition
|
Insert after the BATTERY is
withdrawn
|
Operating
|
| - |
The Burglar alarm RELAY shall be
ON and the HORN ALARM shall be output three times
again. | |
Condition 2
State
|
Description
|
Initial Condition
|
ARM state
|
Transition Condition
|
Insert after the BATTERY is
withdrawn
|
Operating
|
|
|
| 11. |
PANIC ALARM
This function is to give the PANIC ALARM of
the vehicle by using the HORN and HAZARD.
The alarm starts the operating when the TX’s
PANIC signal is input in the state that KEYIN is OFF, ACC is OFF,
IGN1 is OFF, IGN2 is OFF, and stops in the following
conditions.
| (1) |
When the TX is
locked |
| (2) |
When the TX is
unlocked |
| (3) |
When the PANIC signal is
input |
| (4) |
KEY IN ON OR INGN1 ON OR IGN2 ON
INPUT |
| (5) |
After PANIC alarm operating
completion |
| (6) |
When entered into the ARM
mode |
The PANIC ALRM is operated regardless of the
Burglar alarm mode, but it is stopped when entered into the ARM
mode, and the PANIC operating is also performed in the alarm mode by
the Burglar alarm and the PANIC operating is performed under PANIC
operating.
The HORN and HAZARD operating by the Burglar
alarm function shall be prior to the PANIC ALARM and the HORN shall
be OFF during the pause period of 10s under alarm in the alarming
state by Burglar alarm.


T1 : 1 ± 0.1 sec,
T30 : 30 ± 3
sec. |
| 12. |
HORN ANSWER BACK
| (1) |
If the ARM WAIT state is maintained by
the TX LOCK within 4s after entered into the ARM WAIT state by
the TX LOCK, the HORN OUPUT shall be gone side by side when
the HAZARD alarm is operated. |
| (2) |
If the ARM state is maintained by the
TX LOCK within 4s after the TX LOCK input in the ARM state,
the HORN OUPUT shall be gone side by side when the HAZARD
alarm is operated. |
| (3) |
If the ARMWAIT or ARM mode is canceled
for T1, the HORN AND HAZARD shall not be
output. |
| (4) |
Even if other registered TX LOCK
during T1 operating is received, the HORN AND HAZARD shall be
output.

T1 : within 4 sec, T2 : 0.05 ± 0.01
sec. | |