Fuses And Relays › Relay Box (Passenger Compartment): Repair procedures
INSPECTION
RELAY
DOOR
LOCK
1.
There should be continuity between the No.5
in the I/P-J and No.18 terminals in the I/P-D when power and ground
are connected to the No.2 terminal in the I/P-C and No.9 terminal in
the I/P-J.
2.
There should be no continuity between the
No.5 terminal in the I/P-J and No.18 terminal in the I/P-D when
power is disconnected.
DOOR
UNLOCK
1.
There should be continuity between the No.5
terminal in the I/P-J and No.7 terminal in the I/P-K when power and
ground are connected to the No.2 terminal in the I/P-C and No.1
terminal in the I/P-K.
2.
There should be no continuity between the
No.5 terminal in the I/P-J and No.7 terminal in the I/P-D when power
is disconnected.
POWER
WINDOW
1.
There should be continuity between the No.6
in the I/P-F and No.14 terminal in the I/P-D when power and ground
are connected to the No.10 terminal in the I/P-E and No.2 terminal
in the I/P-J.
2.
There should be no continuity between the
No.6 terminal in the I/P-F and No.14 terminal in the I/P-D when
power is disconnected.
HAZARD
LAMP RELAY
1.
There should be continuity between the No.2
of I/P-C and No.3 or No.4 of I/P-E terminals when power and ground
are connected to the No.2 of I/P-C and No.6 of I/P-G
terminals.
2.
There should be no continuity between the
No.2 of I/P-C and No.3 or No.4 of I/P-E terminals when power is
disconnected to the No.2 of I/P-C and No.6 of I/P-G
terminals.
BUGLAR
ALARM HORN
1.
There should be continuity between the No.1
of I/P-C and No.6 of I/P-J terminals when power and ground are
connected to the No.1 of I/P-C and No.8 of I/P-J
terminals.
2.
There should be no continuity between the
No.1 of I/P-C and No.6 of I/P-J terminals when power is disconnected
to the No.1 of I/P-C and No.8 of I/P-J
terminals.
BUGLAR
ALARM START
1.
There should be continuity between the No.10
of I/P-M and No.9 of I/P-K terminals when power and ground are
connected to the No.10 of I/P-M and No.3 of I/P-A
terminals.
2.
There should be no continuity between the
No.10 of I/P-M and No.9 of I/P-K terminals when power is
disconnected to the No.10 of I/P-M and No.3 of I/P-A
terminals.
BLOW
1.
There should be continuity between the No.5
of I/P-A and No.8 of I/P-K terminals when power and ground are
connected to the No.11 of I/P-A and No.8 or No.12 of I/P-M
terminals.
2.
There should be no continuity between the
No.5 of I/P-A and No.8 of I/P-K terminals when power is disconnected
to the No.11 of I/P-A and No.8 or No.12 of I/P-M
terminals.
FUSE
1.
Be sure there is no play in the fuse
holders, and that the fuses are held
securely.
2.
Are the fuse capacities for each circuit
correct?
3.
Are there any blown fuses?
If a fuse is to be replaced, be sure to use
a new fuse of the same capacity. Always determine why the fuse blew
first and completely eliminate the problem before installing a new
fuse.