Control
Algorithm Flow Chart
The base control
algorithm of the ITM ECM is defined by the following
flowchart:

Lock
Mode Description
| •
|
Based on a driver request for lock mode, the
system will supply a fixed torque to the ITM-I
clutch. |
| •
|
When the vehicle exceeds 30KPH the system
will begin to disable lock mode by ramping down the ITM clutch
torque. When the vehicle exceeds 40 KPH the ITM clutch is reduced to
its minimum torque value. Lock mode is re-enabled following the
same speed-to-torque map. |
| •
|
Lock mode is activated based on part
number.

|
| •
|
Lock mode will override all other system
requests except for during an ABS event. During an ABS event the
ITM clutch is turned off. |
| •
|
If there is a speed sensor signal fault, the
speeds are no longer considered reliable and lock mode will be
disabled. |