Home
›
Heating,Ventilation, Air Conditioning
›
Rear Heater
›
Rear Blower Unit
Rear Heater › Rear Blower Unit: Repair procedures
Inspection
1.
Connect the battery voltage and check the blower motor rotation.
2.
If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.
3.
If the problem is corrected, replace the blower motor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove luggage side trim. (Refer to BD- Interior trim)
3.
Disconnect the connector (A) of the blower motor.
4.
Remove the blower motor (B) after loosening the mounting screws.
5.
Installation is the reverse order of removal.