Home › Body Electrical System › Keyless Entry And Burglar Alarm

Keyless Entry And Burglar Alarm: Description and Operation

DESCRIPTION
BURGLAR ALARM SYSTEM
The burglar alarm system is armed automatically after the doors, hood, and tailgate are closed and locked.
The system is set off when any of these things occur :
•
A door is forced open.
•
The tailgate is opened without using the key.
•
The hood is opened.
When the system is set off, the alarm sounds and the hazard lamp flash for about 30 seconds or until the system is disarmed by unlocking the transmitter.
For the system to arm, the ignition switch must be off and the key removed. Then, the body control module must receive signals that the doors, hood, and tailgate are closed and locked. When everything is closed and locked, none of the control unit inputs are grounded.
The door switches, hood switch and tailgate switch are all close and lock the doors with the remote transmitter and then the system arms immediately.
If anything is opened after the system is armed, the body control module gets a ground signal from that switch, and the system is set off.
If one of the switches is misadjusted or there is a short in the system, the system will not arm. As long as the body control module continues to get a ground signal, it thinks the vehicle is not closed and locked and will not arm.
KEYLESS ENTRY SYSTEM
The burglar alarm system is integrated with the keyless entry system. The keyless entry system allows you to lock and unlock the vehicle with the remote transmitter. When you push the LOCK button, all doors lock. When you push the UNLOCK button again, all doors unlock.
The room lamp, if its switch is in the center position, will come on when you press the UNLOCK button. If you do not open a door, the light will go off in about 30 seconds, the doors will automatically relock, and the burglar alarm system will rearm. If you relock the doors with the remote transmitter within 30 seconds, the light will go off immediately.
You cannot lock or unlock the doors with the remote transmitter if the key is in the ignition switch.
The system will signal you when the doors lock and unlock by flashing the hazard lamp once when they lock, and twice when they unlock.
FUNCTION
ANTI-THEFT WARNING SYSTEM

1.
SECURITY LED CONTROL
(1)
If the KEY IN is ON or ACC is ON or IGN1 is ON or IGN2 is ON, the LED shall be OFF.
(2)
When entered into the ARM WAIT mode in the IGN KEY OUT state, control not only the FULL ON but also the BLINKING in the mode other than the ARM WAIT.
(3)
The BLINKING cycle is 2.3 seconds, and it is ON for 0.3 seconds and OFF for 2.0 seconds.

T1 : 0.3s, T2 : 2s
2.
DISARM
Condition 1
State
Description
Initial Condition
ALARM
Transition Condition
-
When 4DOOR or Tailgate is OPEN and TX(Transmitter) UNLOCK is input
-
After 30 seconds in the KEY IN ON and IGN1 ON and IGN2 ON states
-
When all doors are unlocked (LOCK FAIL) within 5 seconds after the TX(Transmitter) LOCK input
Operating
-
ENTRY INTO THE DISARM STATE
-
HORN, HAZARD, Burglar alarm output shall be OFF
-
In the case of the TX UNLOCK input, the HAZARD LAMP signal is output with the cycle of the ON/OFF of 0.5 seconds two times.

Condition 2
State
Description
Initial Condition
In the DISARM state and any one of the IGN KEY OUT & 4DOOR and Tailgate are opened
Transition Condition
When entering TX UNLOCK
Operating
-
Maintain in the DISARM state
-
The HAZARD LAMP signal is output with the ON/OFF cycle of 0.5 seconds two times.

Condition 3
State
Description
Initial Condition
ARM WAIT state
Transition Condition
-
When any one of the 4DOOR, HOOD or Tailgate is opened.
-
When at least one or more doors are unlocked.
-
In case of KEY IN.
-
When the DRIVER KEY UNLOCK(Tailgate KEY UNLOCK) signal is input
Operating
-
ENTRY INTO THE DISARM STATE

Condition 4
State
Description
Initial Condition
AUTOLOCK TIMER1 state
Transition Condition
-
When any one of the 4DOOR, HOOD or Tailgate is opened.
-
In case of KEY IN.
-
LOCK FAIL after the LOCK attempt by the AUTO LOCK.
-
LOCK FAIL after the LOCK attempt by the TX LOCK.
-
LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK(Tailgate KEY LOCK).
Operating
-
ENTRY INTO THE DISARM STATE

Condition 5
State
Description
Initial Condition
AUTOLOCK TIMER2 state
Transition Condition
-
When any one of the 4DOOR, HOOD or Tailgate is opened.
-
In case of KEY IN.
-
LOCK FAIL after the LOCK attempt by the AUTO LOCK.
-
LOCK FAIL after the LOCK attempt by the TX LOCK.
-
LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK
Operating
-
ENTRY INTO THE DISARM STATE

Condition 6
State
Description
Initial Condition
ARM state
Transition Condition
-
IGN KEY ON
-
DRIVER KEY UNLOCK(Tailgate KEY UNLOCK) input.
Operating
-
ENTRY INTO THE DISARM STATE

Condition 7
State
Description
Initial Condition
REARM state
Transition Condition
-
After 30 seconds in the IGN KEY ON state.
-
LOCK FAIL after the LOCK attempt by the TX LOCK.
-
LOCK FAIL after the LOCK attempt by the DRIVER KEY LOCK.
-
When entering DRIVER KEY UNLOCK.
Operating
-
ENTRY INTO THE DISARM STATE
-
Burglar alarm RELAY OFF

Condition 8
State
Description
Initial Condition
REARM state
Transition Condition
-
In case of TX UNLOCK INPUT in the state that any one of the 4DOOR or Tailgate is opened.
-
In case of KEY IN.
-
In case of the 4DOORor Tailgate or HOOD is closed and at least one door is unlocked.
Operating
-
ENTRY INTO THE DISARM STATE
-
In the case of the TX UNLOCK INPUT, the HAZARD LAMP signal is output two times with the ON/OFF cycle of 0.5 seconds.

3.
ARM
Condition 1
State
Description
Initial Condition
ARM state
Transition Condition
When entering TX LOCK
Operating
-
Keep the ARM state
-
The HAZARD LAMP signal is output for 1s once.

Condition 2
State
Description
Initial Condition
ARM WAIT state
Transition Condition
After the ARM WAIT TIMER completion
Operating
-
ENTRY INTO THE ARM state

4.
ALARM
Condition 1
State
Description
Initial Condition
ARM state
Transition Condition
In case of 4DOOR, Tailgate or HOOD is opened.
Operating
-
ENTRY INTO THE ALARM state
-
The Burglar alarm RELAY outputs is ON, and then, inhibit the start.
-
The Horn alarm shall be output three times with the cycle consisting of the ON for 27s(±2s) and the OFF for 10s(±1s). (At this time, the Hazard Lamp signal shall also be output as the Horn alarm.)

Condition 2
State
Description
Initial Condition
REARM state
Transition Condition
In case of 4DOOR, Tailgate or HOOD is opened.
Operating
-
ENTRY INTO THE ALARM state
-
The Horn alarm shall be output three times with the cycle consisting of the ON for 27s(±2s) and the OFF for 10s(±1s). (At this time, the Hazard Lamp signal shall also be output as the Horn alarm.)

T1 : 27 ± 2sec, T2 : 0.4 ~ 0.5 sec,
T3 : 10 ± 1sec.
5.
ARM WAIT
Condition 1
State
Description
Initial Condition
ARM WAIT state
Transition Condition
When entering TX LOCK
Operating
-
Keep ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.

Condition 2
State
Description
Initial Condition
DISARM state & IGN KEY OUT & 4DOOR, Tailgate and HOOD CLOSE state
Transition Condition
-
In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
In case of LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (Tailgate KEY LOCK) INPUT.
-
In case of 4DOOR, Tailgate, HOOD OPEN<CLOSE with all doors locked.
Operating
-
Entry into the ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.
-
Start the ARMWAIT TIMER

Condition 3
State
Description
Initial Condition
ALARM state & IGN KEY OUT & 4DOOR, Tailgate and HOOD CLOSE state
Transition Condition
-
In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
In case of LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (Tailgate KEY LOCK) INPUT.
Operating
-
Entry into the ARM WAIT state
-
OFF the HORN, Burglar alarm output.
-
The HAZARD LAMP signal shall be output for 1s once
-
Start the ARMWAIT TIMER

Condition 4
State
Description
Initial Condition
AUTOLOCK TIMER1 state
Transition Condition
-
In case of LOCK SUCCESS after the LOCK attempt by the AUTOLOCK.
-
In case of LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
In case of LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (Tailgate KEY LOCK) INPUT
Operating
-
Entry into the ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.
-
Start the ARMWAIT TIMER

Condition 5
State
Description
Initial Condition
PREARM state
Transition Condition
-
4DOOR, Tailgate and HOOD are closed and all doors are locked.
Operating
-
Entry into the ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.
-
Start the ARMWAIT TIMER

Condition 6
State
Description
Initial Condition
REARM state
Transition Condition
-
LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (Tailgate KEY LOCK) INPUT.
Operating
-
Entry into the ARM WAIT state
-
The HAZARD LAMP signal shall be output for 1s once.
-
Burglar alarm RLY OFF
-
Start the ARMWAIT TIMER

6.
REARM
Condition 1
State
Description
Initial Condition
ALARM state
Transition Condition
4DOOR, Tailgate and HOOD are closed and after the ALARM PATTERN completion
Operating
-
Entry into the REARM state

7.
AUTO-LOCK TIMER1
Condition 1
State
Description
Initial Condition
ARM state
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 state
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START the AUTOLOCK TIMER1

Condition 2
State
Description
Initial Condition
REARM state
Transition Condition
-
AUTO-LOCK TIMER1 state.
-
TX UNLOCK INPUT.
Operating
-
keep the AUTO-LOCK TIMER1 state
-
CASE1: AUTOLOCK TIMER1 COMPLETION LOCK ATTEMPT.
-
CASE2: TX UNLOCK
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times
-
RESTART THE AUTOLOCK TIMER1

Condition 3
State
Description
Initial Condition
ARM WAIT state
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 state
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER

Condition 4
State
Description
Initial Condition
The DISARM state and 4DOOR, Tailgate and HOOD are closed and IGN KEY OUT
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 STATE
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER1

Condition 5
State
Description
Initial Condition
ALARM state, and 4DOOR, Tailgate and HOOD CLOSE state
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 STATE
-
Burglar alarm RELAY OFF
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER1

Condition 6
State
Description
Initial Condition
REARM state
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER1 STATE
-
Burglar alarm RELAY OFF
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER1

8.
AUTO-LOCK TIMER 2
Condition 1
State
Description
Initial Condition
AUTO-LOCK TIMER2 state
Transition Condition
-
AUTOLOCK TIMER2 COMPLETION.
-
TX UNLOCK INPUT.
Operating
-
keep the AUTO-LOCK TIMER2 state
-
CASE1: AUTOLOCK TIMER1 COMPLETION LOCK ATTEMPT.
-
CASE2: TX UNLOCK
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times
-
RESTART THE AUTOLOCK TIMER1

Condition 2
State
Description
Initial Condition
REARM state
Transition Condition
DISARM state AND 4DOOR & Tailgate CLOSE & HOOD OPEN AND IGN KEY OUT
Operating
-
Entry into the AUTO-LOCK TIMER2 STATE
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER2

Condition 3
State
Description
Initial Condition
ALARM STATE AND 4DOOR & Tailgate CLOSE & HOOD OPEN STATE
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER2 STATE
-
OFF the HORN, Burglar alarm OUTPUT
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER2

Condition 4
State
Description
Initial Condition
PREARM START AND 4DOOR & Tailgate CLOSE & HOOD OPEN STATE
Transition Condition
TX UNLOCK INPUT
Operating
-
Entry into the AUTO-LOCK TIMER2 STATE
-
The HAZARD LAMP signal shall be output with the ON/OFF cycle of 0.5s two times.
-
START THE AUTOLOCK TIMER2

9.
PREARM
Condition 1
State
Description
Initial Condition
AUTO-LOCK TIMER2 state
Transition Condition
-
LOCK SUCCESS after the LOCK attempt by the AUTO LOCK.
-
LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (Tailgate KEY LOCK) INPUT.
Operating
-
Entry into the PREARM state

Condition 2
State
Description
Initial Condition
DISARM state & IGN KEY OUT
Transition Condition
-
LOCK SUCCESS after the LOCK ATTEMPT by the TX LOCK in the state that 4 DOOR or Tailgate or HOOD is opened.
-
LOCK SUCCESS after the LOCK ATTEMPT by the DRIVER KEY LOCK (Tailgate KEY LOCK) INPUT in the state that 4 DOOR or Tailgate or HOOD is opened.
-
The DOOR is turned to the CLOSE state from the OPEN state in the state that all doors are locked. But, the HOOD is opened.
Operating
-
Entry into the PREARM state

Condition 3
State
Description
Initial Condition
ALARM state & IGN KEY OUT & 4DOOR or Tailgate or HOOD OPEN
Transition Condition
-
LOCK SUCCESS after the LOCK attempt by the TX LOCK.
-
LOCK SUCCESS after the LOCK attempt by the DRIVER KEY LOCK (Tailgate KEY LOCK) INPUT.
Operating
-
Entry into the PREARM state
-
OFF the HORN, HAZARD, Burglar alarm OUTPUT

10.
RESET
Condition 1
State
Description
Initial Condition
ALARM, REARM state
Transition Condition
Insert after the BATTERY is withdrawn
Operating
-
The Burglar alarm RELAY shall be ON and the HORN ALARM shall be output three times again.

Condition 2
State
Description
Initial Condition
ARM state
Transition Condition
Insert after the BATTERY is withdrawn
Operating
-
Keep the ARM state.

11.
PANIC ALARM
This function is to give the PANIC ALARM of the vehicle by using the HORN and HAZARD.
The alarm starts the operating when the TX’s PANIC signal is input in the state that KEYIN is OFF, ACC is OFF, IGN1 is OFF, IGN2 is OFF, and stops in the following conditions.
(1)
When the TX is locked
(2)
When the TX is unlocked
(3)
When the PANIC signal is input
(4)
KEY IN ON OR INGN1 ON OR IGN2 ON INPUT
(5)
After PANIC alarm operating completion
(6)
When entered into the ARM mode
The PANIC ALRM is operated regardless of the Burglar alarm mode, but it is stopped when entered into the ARM mode, and the PANIC operating is also performed in the alarm mode by the Burglar alarm and the PANIC operating is performed under PANIC operating.
The HORN and HAZARD operating by the Burglar alarm function shall be prior to the PANIC ALARM and the HORN shall be OFF during the pause period of 10s under alarm in the alarming state by Burglar alarm.

T1 : 1 ± 0.1 sec,
T30 : 30 ± 3 sec.
12.
HORN ANSWER BACK
(1)
If the ARM WAIT state is maintained by the TX LOCK within 4s after entered into the ARM WAIT state by the TX LOCK, the HORN OUPUT shall be gone side by side when the HAZARD alarm is operated.
(2)
If the ARM state is maintained by the TX LOCK within 4s after the TX LOCK input in the ARM state, the HORN OUPUT shall be gone side by side when the HAZARD alarm is operated.
(3)
If the ARMWAIT or ARM mode is canceled for T1, the HORN AND HAZARD shall not be output.
(4)
Even if other registered TX LOCK during T1 operating is received, the HORN AND HAZARD shall be output.