Body control
module (A) receives various input switch signals controlling time
and alarm functions for tail lamp, rear fog lamp, tail lamp auto
cut, auto light, DRL, seat belt reminder warning, key operated
warning, parking brake warning, over speed warning, ignition key
hole illumination, room lamp control, power window delay time
control, keyless entry control, burgular alarm control, auto door
lock/crash door unlock, key reminder & front/rear heated
control.
|

|
| 1. |
WASHER INTERLOCKING WIPER
| (1) |
If the Washer SW is ON in the IGN2 SW ON
state, then the Wiper output shall be ON after T1, and if the
Washer SW input is ON for 0.2~0.6 seconds, then the Wiper
output shall be OFF after T3. However, WASHER SW input shall
be disregarded during the Washer Wiper operating, but after
operating the Washer Wiper, WASHER SW input shall be accepted
first.

T1 : 0.3 ± 0.1s, T2 : 0.2~0.6s, T3 : 0.7
± 0.1s
In case of T2 is less than 0.2s,
T3=0 |
| (2) |
If the Washer SW is ON in the IGN2 SW ON
state, then the Wiper output shall be ON after T1, and if the
Washer SW is ON over 0.6 seconds, after the Washer SW is OFF
and the Wiper output shall be ON for 2.5~3.8 seconds and then,
the Wiper output shall be OFF. However, WASHER SW input shall
be disregarded during the Washer Wiper operating, but after
the Washer Wiper operating, WASHER SW input be accepted
first.

T1 : 0.3 ± 0.1s, T2 : more than 0.6s, T3
: 2.5~3.8s |
| (3) |
During INT Wiper operating, if the
Washer SW is ON over 0.6 seconds, then the Washer Interlocking
Wiper output shall be ON. If the Washer SW is ON for 0.2~0.6
seconds, then the Wiper output shall be ON once.

T1 : 0.3 ± 0.1s, T2 : more than
0.6s
T3 : 2.5~3.8s ± 0.1s, T4 : INT
TIME-0.7s,
T5 : 0.2~0.6s, T6 : 0.7 ±
0.1s | |
| 2. |
MIST INTERLOCKING WIPER
| (1) |
In IGN2 SW ON, if the MIST SW is ON for
60ms or more, within 100ms, and then, wiper output shall be ON
for 700ms within 100ms.

T1 : Min 60 ms, T2 : Max 100
ms,
T3 : 700 ± 100
ms |
| (2) |
If MIST SW input is continued, WIPER
output shall be maintain the ON state, and then if MIST SW is
OFF, the Wiper output shall be ON for 700ms since OFF
time.

T1 : Min 60 ms, T2 : Max 100
ms,
T3 : 700 ± 100
ms |
| (3) |
Mist SW input shall be disregarded by
INT WIPER, WASHER interlocking WIPER during operating
WIPER. | |
| 3. |
HEAD LAMP WASHER
| (1) |
In the state that IGN2 SW is ON and
HEADLAMP is ON, if the headlamp washer SW is ON, the headlamp
washer relay shall be ON. |
| (2) |
After the operation by inputting the
operation condition, the output shall be inhibited by
disregarding the input condition occurred for 10
seconds.

T1 : 0.65 ± 0.1 sec,
T2 : 3.5 ± 0.1 sec,
T3 : 10 ± 1
sec. | |
| 4. |
VEHICLE SPEED (SENSITIVE TYPE) INT
WIPER
According to the vehicle speed, control
intermittent time of the Intermittent Wiper.
| C. |
INPUT the vehicle speed, intermittent
time set VOLUME value |
| -
|
Change the WIPER by calculating
the intermittent time according to the vehicle
speed. | |
| (1) |
Input of Vehicle speed
Calculate the vehicle speed by the
number of Input PULSE for 1 second.
1 [PULSE/sec] = (60[Km/h] × 60[sec]) /
(637 × 4 PULSE) ≒ 1.41[Km/h] |
| (2) |
Output of Vehicle speed
Count the number of the PULSE for 1
second, and compare with the former value, and then define the
higher value of the vehicle speeds as the vehicle speed for
intermittent time output.
V = max (Vnew, Vold)
But, Vnew: the present vehicle speed,
Vold: the former vehicle
speed |
| (3) |
Output of Intermittent time ratio
(vehicle speed: 0Km/h)
Calculate the INT time rate by inputting
the INT Time set Volume value (input voltage)
The INT Time Rate is to indicate the
position where the Volume is located from the Slow (100%) to
the Fast (0%) of the Knob. Therefore the Volume shall be
linearly calibrated about the input
voltage. |
| (4) |
Output of Standard Intermittent
Time
Calculate the intermittent time of the
intermittent time ratio 100% and 0% at the vehicle speed (V)
computed above by linear correction and then, calculate the
standard intermittent time by the proportional distribution of
the intermittent time ratio computed in (3) item.
| A. |
If the variation of the standard
intermittent time is less than 0.3 sec, should not renew
the intermittent time. |
| B. |
If the standard intermittent time
is less than 0.2 sec, continually
operate. |
| C. |
When the INT Time Timer (passed
time) is over 10 seconds, if the vehicle is speeded up
(from 0 km/h to 7km/h and more), then the Wiper shall be
operated. | | |
| 5. |
TAIL LAMP AUTO CUT
After Key IN SW is On, if Tail SW is On, then
Key IN SW shall be OFF; when the driver's door is opened, then the
Tail Lamp shall be OFF automatically.
Also, in the state that the KEY IN SW is ON,
after the driver's door is opened, if the KEY IN SW is OFF, then the
Tail Lamp shall be OFF automatically.
After the Auto Cut, if the Tail SW is ON after
OFF again, the Tail Lamp shall be ON, and the Auto Cut function
shall be canceled.
After the Auto Cut, when KEY IN SW is ON
again, TAIL LAMP shall be ON, and the Auto Cut function shall be
canceled.
In the state of the AUTO CUT, if mounting or
removing the BATTERY, then the AUTO CUT state shall be
continued.

|
| 6. |
HEAD LAMP LOW CONTROL
If HEAD LAMP LOW SW is On in the IGN1 On
state, HEAD LAMP HIGH RELAY shall be ON so that HEAD LAMP HIGH can
be controlled by HEAD LAMP RELAY and M/F SW.

|
| 7. |
AUTO LIGHT CONTROL
| (1) |
It shall be able to operate only in case
of AUTO LIGHT is active, and comply with CALIBRAION PARAMETER
TABLE of each spec. |
| (2) |
In GN1 SW ON state, if the supply
voltage of the AUTO LIGHT SENSOR is less than 4v or more than
6v, it is determined as the fault. In the fault state, in case
of the AUTO LIGHT SW is ON, always HEAD LAMP RELAY shall be ON
regardless of the Sensor value. FILTERING TIME for the fault
and recovery with regard to the supply voltage is 300 msec
respectively. |
| (3) |
In the condition of LIGHT ON, when the
AUTO LIGHT SENSOR value is entered into AUTO LIGHT control
condition, then LIGHT shall be ON
immediately. |
| (4) |
If IGN1 SW is ON, and AUTO LIGHT SW is
ON, and in LIGHT OFF state, and in case of AUTO LIGHT SENSOR
value is the input value of the LIGHT ON, LIGHT shall be ON
after 2.5 ± 0.2sec. |
| (5) |
In LIGHT ON state, in case of the AUTO
LIGHT SENSOR value is the input value of the LIGHT OFF, LIGHT
shall be OFF after 2.5 ±
0.2sec. |
| (6) |
If the SENSOR value is the input value
of the TAIL LAMP ON, then TAIL LAMP RELAY shall be ON only,
and if it is the input value of the HEAD LAMP ON, then HEAD
LAMP HIGH RELAY shall be ON so that HEAD LAMP HIGH can be
controlled by TAIL LAMP RELAY, HEAD LAMP RELAY, and
multifunction (M/F) SW. |
| (7) |
In the condition of LIGHT ON, when AUTO
LIGHT SW is ON, HEAD LAMP RELAY shall be ON immediately, and
when AUTO LIGHT SW is OFF, LIGHT shall be OFF
immediately.
The LIGHT ON value of the AUTO LIGHT
SENSOR shall be complied with the table below.
|
TAIL LAMP
|
HEAD LAMP
|
ON
|
0.81±0.05V
|
0.81±0.05V
|
OFF
|
1.41±0.05V
|
1.41±0.05V
|

|
| (8) |
The time chart according to filtering
time and sensor for each applicable area shall be as
follow.

T1 : 12 ± 0.2s, T2 : 12 ±
0.2s | |
| 8. |
DAYTIME RUNNING LIGHT
DRL (DAYTIME RUNNING LIGHT) OPTION is
classified into the following two cases by the DRL OPTION LINE
input.
| (1) |
NON-DRL OPTION: In the case that DRL
OPTION LINE is not connected. |
| (2) |
DRL OPTION: In the case that DRL CANADA
OPTION LINE is connected and electrically
grounded. | |
| 9. |
DRL (CANADA)
If the IGN2 is ALT "L" are On, supply the
power to the HEAD LAMP HIGH LAMP by turning the DRL CANADA RELAY
ON.
If HEAD LAMP LOW RELAY is On by the HEAD LAMP
switch, the DRL function shall be canceled. If the HEAD LAMP HIGH
RELAY is On by the HEADLAMP HIGH switch or PASSING switch, the DRL
function shall be canceled.
If P/BRAKE switch is ON(PARK), the DRL
function shall be canceled.
In IGN2 state, if the HEAD LAMP HIGH RELAY is
On by the HEADLAMP HIGH switch or PASSING switch, the HEAD LAMP HIGH
INDICATOR shall be ON.

|
| 10. |
BUZZER SOUND
| (1) |
BUZZER SOUND SPECIFICATION
|
Frequency
|
Frequency DUTY
|
Cycle
|
Sound Pressure
|
Remark
|
SEAT BELT WARNING
|
800Hz
|
50%
|
1.0s
|
70±10Db
|
Damped Sound
|
KEY OPERATED
|
800Hz
|
50%
|
0.7s
|
70±10Db
|
Damped Sound
|
OVER SPEED WARNING / SEAT BELT REMINDER
(EC)
|
800Hz
|
50%
|
1.0s
|
70±10Db
|
Continuous Sound
|
PARKING START WARINGI
|
800Hz
|
50%
|
1.0s
|
70±10Db
|
Continuous
Sound
|

|
| (2) |
The Priority Order: OVER SPEED WARNING
> S/BELT WARNING > KEY OPERATED WARNING > PARKING
START WARNING |
| (3) |
If the output is OFF, maintain the
output until the OFF cycle |
| (4) |
Sound pressure measurement distance :
1.0 m | |
| 11. |
SEAT BELT REMINDER
Condition 1
State
|
Description
|
Initial
condition
|
IGN1
OFF
|
Event
|
Driver
side seat belt is belted and IGN1 is ON
|
Action
|
| -
|
Start Bulb check 6 seconds driver
indicator blinking |
| -
|
The automaton state is changed to
IGN1 ON DRIVER
BELTED | |
Condition 2
State
|
Description
|
Initial
condition
|
IGN1
OFF
|
Event
|
Driver
side seat belt is unbelted and IGN1 is ON
|
Action
|
| -
|
Start Bulb check 6 seconds driver
indicator blinking |
| -
|
Start Normal 6 seconds driver
indicator blinking |
| -
|
Start 6 seconds buzzer
warning |
| -
|
If ALT'L is ON then start
30sec(ALT Timer) timer after 6 seconds timer
elapsed |
| -
|
The automaton state is changed to
IGN1 ON DRIVER
UNBELTED | |
Condition 3
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER BELTED
|
Event
|
IGN1 is
OFF
|
Action
|
| -
|
Stop Bulb check 6 seconds driver
indicator blinking |
| -
|
The automaton state is changed to
IGN1
OFF | |
Condition 4
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER BELTED
|
Event
|
Driver
side seat belt is unbelted
|
Action
|
| -
|
Start Normal 6 seconds driver
indicator blinking |
| -
|
Start 6 seconds buzzer
warning |
| -
|
If ALT'L is ON then start 30sec
timer after 6 seconds timer
elapsed |
| -
|
The automaton state is changed to
IGN1 ON DRIVER
UNBELTED | |
Condition 5
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER UNBELTED
|
Event
|
IGN1 is
OFF
|
Action
|
| -
|
Stop Bulb check 6 seconds driver
indicator blinking |
| -
|
Stop Normal 6 seconds driver
indicator blinking |
| -
|
Stop 6 seconds buzzer
warning |
| -
|
The automaton state is changed to
IGN1
OFF | |
Condition 6
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER UNBELTED
|
Event
|
Driver
side seat belt is belted
|
Action
|
| -
|
Stop Normal 6 seconds driver
indicator blinking |
| -
|
Stop 6 seconds buzzer
warning |
| -
|
The automaton state is changed to
IGN1 ON DRIVER
BELTED | |
Condition 7
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER UNBELTED
|
Event
|
Started
30sec timer is elapsed
|
Action
|
| -
|
Start buzzer and driver indicator
Pattern (11 times (6sec ON/24sec OFF) + 6sec
ON) |
| -
|
The automaton state is changed to
PATTERN | |
Condition 8
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER UNBELTED
|
Event
|
ALT'L
0>1
|
Action
|
| -
|
Start 30sec timer (re-initialize
timer for a full 30sec
duration) | |
Condition 9
State
|
Description
|
Initial
condition
|
IGN1 ON
DRIVER UNBELTED
|
Event
|
ALT'L
1>0
|
Action
|
|
Condition 10
State
|
Description
|
Initial
condition
|
PATTERN
|
Event
|
IGN1 is
OFF
|
Action
|
| -
|
Stop Buzzer and driver indicator
Pattern |
| -
|
The automaton state is changed to
IGN1
OFF | |
Condition 11
State
|
Description
|
Initial
condition
|
PATTERN
|
Event
|
Driver
side seat belt is belted
|
Action
|
| -
|
Stop Buzzer and driver indicator
Pattern |
| -
|
The automaton state is changed to
IGN1 ON DRIVER
BELTED | |
Condition 12
State
|
Description
|
Initial
condition
|
PATTERN
|
Event
|
Pattern
finished or ALT'L is OFF
|
Action
|
| -
|
Stop Buzzer and driver indicator
Pattern |
| -
|
The automaton state is changed to
IGN1 ON DRIVER
UNBELTED | |
|
| 12. |
KEY OPERATED WARNING
| (1) |
In state of KEY IN SW is IN, if the
DRIVER DOOR is opened, then the CHIME BUZZER output shall be
continued with the cycle of 0.7
seconds. |
| (2) |
If KEY IN SW is OUT or the driver's door
is closed during the Chime Buzzer output, then the output
shall be OFF.

T1 : 0.7 ±
sec. | |
| 13. |
PARKING START WARNING
In the state that the IGN1 is ON or the
Parking Brake is pulled, if the speed of vehicle is maintained over
10 km/h for 2~3 seconds or more, then the Chime Buzzer output shall
be continued with 1 second cycle of the ON/OFF (0.3/0.7 seconds).
But, after the speed of vehicle is maintained over 10 km/h for 2~3
seconds or more, if the Parking Brake is pulled, output
immediately.

T1 : 2.5±0.5 sec, T2 : 0.3±0.1
sec,
T3 : 0.7±0.1
sec. |
| 14. |
IGN KEY HOLE ILLUMINATION
| (1) |
If the driver's door (or assist’s door)
is opened in the state that the IGN1 SW is OFF, then the IGN
Key Hole Illumination shall be
ON. |
| (2) |
In the (1) state, if the driver's door
(or assist's door) is closed, then the IGN Key Hole
Illumination shall be OFF after it is in the ON state for 30
seconds. |
| (3) |
During the (1) and (2) operating, if the
IGN1 SW is On, the IGN Key Hole Illumination shall be OFF
immediately. |
| (4) |
But, if it is in the ARM Mode, then the
IGN Key Hole Illumination shall be OFF
immediately.

T1 : 30 ± 1
sec. | |
| 15. |
DEFOGGER TIMER
| (1) |
If the Defogger SW is ON after the ALT
"L" is ON in the state that the IGN1 SW is ON, then the
Defogger output shall be ON for 20 minutes. (Operating in the
state of the ENGINE RUNNING) |
| (2) |
If the DEFOGGER SW is ON again while the
DEFOGGER output is ON, then the DEFOGGER output shall be
OFF. |
| (3) |
If the ALT "L" is OFF or IGN1 is OFF
while the DEFOGGER output is ON, then the DEFOGGER output
shall be OFF. |
| (4) |
If the ALT "L" > 10 volts, then it
shall be in the Engine Running State (ALT "L" shall be ON); if
the ALT "L" < 5 volts, then it shall be in the Engine Stop
State (ALT "L" shall be OFF). Also, if the ALT "L" is more
than 5 and less than 10 volts, then the former state shall be
maintained. |
| (5) |
If the defogger SW is pressed and the
ALT "L" is ON, there shall be no the DEFOGGER RLY
output.

T1 : 60 ± 20 msec, T2 : 20 ± 1
min. | |
| 16. |
DELAY ROOM LAMP & KEYLESS UNLOCK
TIMER
Condition 1
State
|
Description
|
Initial
Condition
|
Room
lamp OFF & IGN1 OFF & 4DOOR AND Tailgate
CLOSE
|
Transition Condition
|
In the
state that all doors are closed, the 4DOOR or T/GATE is opened
over 0.1 seconds.
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 20 min |
| -
|
ROOM LAMP ON for 20 ± 1
min | |
Condition 2
State
|
Description
|
Initial
Condition
|
Room
lamp OFF & IGN1 OFF & 4DOOR AND Tailgate
CLOSE
|
Transition Condition
|
In case
of UNLOCK by the TX
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 30s |
| -
|
ROOM LAMP ON for 30 ±
3seconds | |
Condition 3
State
|
Description
|
Initial
Condition
|
Room
lamp OFF & IGN1 OFF & 4DOOR AND Tailgate
CLOSE
|
Transition Condition
|
IGN1 ON
and 4 DOOR or Tailgate OPEN over 0.1 seconds
|
Operating
|
| -
|
Entry into the ROOM LAMP ON
state |
|

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.
Condition 4
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 30s & IGN1 OFF
|
Transition Condition
|
In the
state that all doors are closed, the 4DOOR or Tailgate is
opened over 0.1 seconds.
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 20 min |
| -
|
ROOM LAMP ON for 20 ±
1min. | |
Condition 5
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 30s & IGN1 OFF
|
Transition Condition
|
In case
of UNLOCK by the TX.
|
Operating
|
| -
|
Maintain in the ROOM LAMP ON state
for 30s |
| -
|
Extend the ROOM LAMP ON state for
30
seconds. | |
Condition 6
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 30s & IGN1 OFF
|
Transition Condition
|
IGN1 ON,
or after 30 seconds, or when entered into the ARM state, or
when all doors are locked.
|
Operating
|
| -
|
Entry into the ROOM LAMP DECAYING
state |
| -
|
After the ROOM LAMP is decayed for
2 ± 0.2 seconds, it shall be
OFF. | |

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.
Condition 7
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 20min & IGN1 OFF
|
Transition Condition
|
IGN1
ON
|
Operating
|
| -
|
Entry into the ROOM LAMP ON
state |
|
Condition 8
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 20min & IGN1 OFF
|
Transition Condition
|
4DOOR
AND Tailgate CLOSE
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 30s. |
| -
|
ROOM LAMP ON for 30 ± 3
seconds. | |
Condition 9
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON for 20min & IGN1 OFF
|
Transition Condition
|
4DOOR
AND Tailgate CLOSE & When All doors are locked, or After
20 minutes
|
Operating
|
| -
|
Entry into the ROOM LAMP DECAYING
state |
| -
|
The ROOM LAMP is decayed for 2 ±
0.2 seconds and then, shall be
OFF. | |

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.
Condition 10
State
|
Description
|
Initial
Condition
|
ROOM
LAMP DELAY & IGN1 OFF
|
Transition Condition
|
In the
state that all doors are closed, 4DOOR or T/GATE OPEN over 0.1
seconds
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 20min |
| -
|
ROOM LAMP ON for 20 ±
1minutes. | |
Condition 11
State
|
Description
|
Initial
Condition
|
ROOM
LAMP DELAY & IGN1 OFF & 4DOOR AND Tailgate
CLOSE
|
Transition Condition
|
In case
of UNLOCK by the TX
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 30s |
| -
|
ROOM LAMP ON for 30 ± 3
seconds. | |
Condition 12
State
|
Description
|
Initial
Condition
|
ROOM
LAMP DELAY
|
Transition Condition
|
After
completing the decaying
|
Operating
|
| -
|
Entry into the ROOM LAMP OFF
state |
|
Condition 13
State
|
Description
|
Initial
Condition
|
ROOM
LAMP DELAY
|
Transition Condition
|
IGN1 ON
and OPEN 4 DOOR or Tailgate for 0.1 seconds
|
Operating
|
| -
|
Entry into the ROOM LAMP ON
state |
|

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms
Condition 14
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON & IGN1 ON & 4DOOR or Tailgate
OPEN
|
Transition Condition
|
4DOOR
AND Tailgate CLOSE
|
Operating
|
| -
|
Entry into the ROOM LAMP DECAYING
state |
| -
|
The ROOM LAMP is decayed for 2 ±
0.2 seconds and then, shall be
OFF. | |
Condition 15
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON & IGN1 ON & 4DOOR or Tailgate
OPEN
|
Transition Condition
|
IGN1
OFF
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 20min |
| -
|
ROOM LAMP ON for 20 ±
1minutes. | |
Condition 16
State
|
Description
|
Initial
Condition
|
ROOM
LAMP ON & IGN1 ON & 4DOOR or Tailgate
OPEN
|
Transition Condition
|
4DOOR
AND Tailgate CLOSE & IGN1 OFF
|
Operating
|
| -
|
Entry into the ROOM LAMP ON state
for 30s |
| -
|
ROOM LAMP ON for 30 ±
3seconds. | |

T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100ms
| 1. |
When the IGN1 is ON, there shall
be no blinking of the ROOM
LAMP. |
| 2. |
The decaying of the ROOM LAMP
should be more than 32
steps. | | |
| 17. |
POWER WINDOW TIMER
| (1) |
When the IGN2 SW is ON, then the Power
Window Relay output shall be
ON. |
| (2) |
When the IGN2 SW is OFF, then the Power
Window output shall be OFF after the output is maintained ON
for 30 seconds. |
| (3) |
Maintained ON for 30
seconds. |
| (4) |
In the condition of the above (2), if
the driver’s or assist’s door is opened, then the output shall
be OFF immediately. |
| (5) |
In the state that the driver's or
assist's door is opened, if the IGN is OFF, then the Power
Window output shall be OFF. |
| (6) |
The SAFTEY POWER WINDOW ECU Output-port
shall be controlled the same as the POWER WINDOW RELAY
does.

T1 : 30 ± 3
sec. | |
| 18. |
DOOR LOCK/UNLOCK RELAY CONTROL
| (1) |
2-TURN UNLOCK SPECIFICATION

|
UNLOCK RLY
|
DOOR UNLOCK
|
LOCK RLY
|
CENTRAL LOCK
|
OFF
|
OFF
|
ON
|
CENTRAL UNLOCK
|
ON
|
ON
|
OFF
|
DRIVER UNLOCK
|
OFF
|
ON
|
OFF
|
| |
| 19. |
CENTRAL DOOR LOCK/UNLOCK
| (1) |
After the driver's door key lock SW is
on, if the driver's door ACTUATOR UNLOCK SW changes from
UNLOCk to LOCK within 3s, ALL DOOR LOCK output shall be ON for
T1. But, in case of KEY IN and IGN1 SW ON, output shall be
inhibited. |
| (2) |
After the driver's door key unlock SW is
on, if the driver's door ACTUATOR UNLOCK SW changes from LOCK
to UNLOCK within 3s, ALL DOOR UNLOCK output shall be ON for
T1. |
| (3) |
When the TX (Transmitter) LOCK signal is
received, all DOOR LOCK output shall be ON for
T1. |
| (4) |
When the TX UNLOCK signal is received,
all DOOR UNLOCK output shall be ON for
T1. |
| (5) |
If the Door LOCK Switch (Power window)
is locked , all DOOR LOCK output shall be ON for
T1. |
| (6) |
If the Door UNLOCK Switch (Power window)
is unlocked, all DOOR UNLOCK output shall be ON for T1.But, in
ARM state, the operation by POWER WINDOW UNLOCK Switch shall
be inhibited. |
| (7) |
The LOCK/UNLOCK by the SAFETY KNOB is
non-interlocking. (Mechanical
operation) |
| (8) |
When connected to the BATTERY, there
shall be no malfunction.(there shall be no malfunction in the
KEY IN position) |
| (9) |
Don't receive the input with less than
60msec(KEY LOCK/UNLOCK SW). |
| (10) |
During output, if there are the output
request, the current output shall be OFF immediately, and
after 100ms delay, and then, perform the reverse direction
output. But, if there are the output request during 100ms
delay, perform the output for the last output request
occurred. |
| (11) |
In case of the Lock output and Unlock
output condition are occurred at the same tine, perform the
lock output and disregard the unlock
output. |
| (12) |
In case of all DOOR UNLOCK(UNLOCK)
Switch is LOCK(UNLOCK) state, the LOCK(UNLOCK) request in
power window always output does not
output. |
| (13) |
In case of DRIVER DOOR UNLOCK Switch is
UNLOCK state, the request of DRIVER DOOR UNLOCK does not
output. |
| (14) |
During DRIVER DOOR UNLOCK output, in
case of the output request of ALL DOOR UNLOCK, perform DRIVER
DOOR UNLOCK output according to ALL DOOR UNLOCK
output.

T1 : 0.5 ± 0.1 sec, T2 : MAX 3
sec. | |
| 20. |
2-TURN UNLOCK
| (1) |
IF DRIVER KEY UNLOCK SW is OFF >ON
(DRIVER DOOR LOCK SW is UNLOCK mechanically and BCM doesn't
output) and then the Driver's ACTUATOR UNLOCK SW is LOCK >
UNLOCK within 0.5s and Driver key unlock SW is OFF > ON
within T1, all door unlock output shall be ON for
T2.. |
| (2) |
IF DRIVER KEY UNLOCK SW is OFF > ON
(DRIVER DOOR LOCK SW is UNLOCK mechanically and BCM doesn't
output) and then the Driver's ACTUATOR UNLOCK SW is LOCK >
UNLOCK within 0.5s and receives TX UNLOCK within T1, the
UNLOCK output shall be ON to all doors for
T2. |
| (3) |
When the TX UNLOCK signal is received,
the DRIVER DOOR UNLOCK output shall be ON for T2. But, if the
TX UNLOCK signal is received within T1, the UNLOCK output
shall be ON to all doors for
T2. |
| (4) |
If after the TX UNLOCK signal is
received, the DRIVER KEY UNLOCK SW is turned to ON from OFF
within T1, the UNLOCK output shall be ON to all doors for
T2. |
| (5) |
Even if other registered TX signal
within T1 is received, the signal shall regard as the same TX
signal. |
| (6) |
The DOOR LOCK(UNLOCK) output produced by
the change of the DRIVER DOOR LOCK SW(KNOB) shall be not
output.

T1 : 4 ± 1 sec, T2 : 0.5 ± 0.1
sec. | |
| 21. |
IGN KEY REMINDER
| (1) |
If the Vehicle speed is over 3Km/h, then
this function doesn't act on. |
| (2) |
If KEY IN Switch is IN & the
driver's door is opened & the driver's DOOR UNLOCK Switch
is locked, then after 0.5 seconds, the unlock signal shall be
output to the driver's door for
1s. |
| (3) |
If it is in state of that KEY IN SW is
IN & assist's DOOR is OPEN & assist's DOOR UNLOCK SW
is LOCK, and after 0.5s, and then perform the ALL DOOR UNLOCK
output for 1 second. |
| (4) |
When (2) items are met at the same time,
after 0.5 seconds, the unlock signal shall be output to all
doors for 1 second in conformity with (3)
item. |
| (5) |
Although the unlock signal is output for
1 s by the (2) items, if the lock state is maintained, the
unlock signal shall be output at maximum three times (except
for 1s output). (1s cycle: 0.5s
ON/OFF) |
| (6) |
After perform (5) items, in case of LOCK
state is maintained, and in case of DOOR CLOSE, and then
attempt the ALL DOOR UNLOCK one
time. |
| (7) |
In the KEY IN Switch is IN state, if the
driver's door is closed within 0.5 seconds as soon as the
driver's DOOR UNLOCK SW is turned to the LOCK from the UNLOCK,
the unlock signal shall be output to the driver's door for 1 s
one time. |
| (8) |
In the KEY IN Switch is IN state, if the
driver's door is closed within 0.5 seconds as soon as the
driver's DOOR UNLOCK Switch is turned to the LOCK from the
UNLOCK, and after output DEAD UNLOCK for 0.5 s and 20 msec,
and then, the unlock signal output shall be ON to all doors
for 1 s one time. |
| (9) |
In the KEY IN Switch is IN state, if the
assist's door is closed within 0.5 seconds as soon as the
assist's DOOR UNLOCK Switch is turned to the LOCK from the
UNLOCK, the unlock signal shall be output to all doors for 1 s
one time. |
| (10) |
In the KEY IN Switch is IN state, if the
driver's DOOR UNLOCK Switch is turned to the LOCK from the
UNLOCK within 0.5 seconds as soon as the driver’s door is
turned to the closed state from the opened state, then the
Unlock signal shall be output to the driver's door for 1
second one time. |
| (11) |
In the KEY IN Switch is IN state, if the
assist's DOOR UNLOCK Switch is turned to the LOCK from the
UNLOCK within 0.5 seconds as soon as the assist's door is
turned to the closed state from the opened state, then the
Unlock signal shall be output to all doors for 1 second one
time. |
| (12) |
In the KEY IN state, after the DRIVER
DOOR or ASSIST DOOR are opened, if the doors are locked by the
Power window LOCK Switch, the unlock signal shall be output to
all doors. |
| (13) |
To determine whether the RETRY signal is
output or not performs at the beginning time of the RETRY
output. (After 1.5 seconds from the first UNLOCK
output) |
| (14) |
Even if the condition is not maintained
for 0.5s after the UNLOCK condition is satisfied, the unlock
signal shall be output. But, after the condition is satisfied
as the result that the DOOR LOCK Switch is turned to the LOCK
from the UNLOCK, if the KEY IN Switch is OFF at the passage
time of 0.5s, the unlock signal shall not be
output.

T1, T3 : 0.5 ± 0.1 sec,
T2 : 1 ± 0.1 sec,
T4 : 0.5 sec
Max | |
| 22. |
CRASH DOOR UNLOCK
| (1) |
In the IGN SW ON state, whenever the AIR
BAG signal is received, the unlock signal shall be output
always. |
| (2) |
During the unlock output, even if the
IGN SW is turned to the OFF from the ON, the unlock output is
maintained for the remained
time. |
| (3) |
If the air bag signal is received first
and then, the IGN SW is turned to the ON from the OFF, the
unlock signal shall not be
output. |
| (4) |
After the UNLOCK output, if the DRIVER
or ASSIST, REAR DOOR LOCK SW are turned to the LOCK from the
UNLOCK, the unlock signal shall be output for
T3. |
| (5) |
The AUTO DOOR LOCK function is not
performed in the CRASH UNLOCK
condition. |
| (6) |
The CENTRAL DOOR LOCK function is not
performed during the CRASH UNLOCK output or after it. But,
after the IGN is OFF, if the crash unlock function is reset,
the CENTRAL DOOR LOCK function is normally
performed. |
| (7) |
The CRASH DOOR UNLOCK function is prior
to the LOCK/UNLOCK control by the other
functions. |
| (8) |
The LOCK/UNLOCK requirement by the other
functions is disregarded during the CRASH DOOR UNLOCK output
or after it. But, if the IGN1 SW is OFF and IGN2 SW is OFF,
the LOCK/UNLOCK control by the other functions shall be
performed.

T1 : 0.2 sec, T2 : 40 msec,
T3 : 5 ± 0.5 sec.
*1 ON : IGN1 ON or IGN2 ON
OFF : IGN1 OFF and IGN2
OFF | |
| 23. |
AUTO DOOR LOCK
| (1) |
The function of the AUTO DOOR LOCK shall
be operated in case of the AUTO DOOR LOCK is active
only. |
| (2) |
In case of the vehicle speed set in the
state of that IGN1 SW is ON than the standard is maintained
for 2~3 seconds, perform the LOCK output. But, if the all DOOR
is LOCK state, or all DOOR is FAIL, do not perform the LOCK
output. |
| (3) |
After the lock output of the (1) item,
if any one of all doors is unlocked, the lock signal shall be
output at maxim three times. (1s cycle) But, during the
3-output operating, if the door state is turned to the LOCK
from the UNLOCK, disregard
it. |
| (4) |
After the 3-output operating, if a door
is Unlocked, the door equivalent for the UNLOCK state shall be
treated as FAIL. |
| (5) |
After the door treated as Fail is turned
to the LOCK from the UNLOCK, and then if the door is unlocked,
the lock signal shall be output
once. |
| (6) |
After the LOCK output of (2) item, if
the locked door is unlocked, the lock signal shall be output
once. |
| (7) |
But, after the LOCK output, even if the
unlock state is maintained, the lock signal shall be output to
the door (the unlock state)
once. |
| (8) |
When the IGN SW is OFF, the door treated
as Fail performs the CLEAR
function. |
| (9) |
The AUTO DOOR LOCK function is not
performed in the CRASH UNLOCK condition.

T1 : 2.5 ± 0.5 sec, T2 : 0.5 ± 0.1
sec. | |
| 24. |
3KM SIGNAL OUTPUT CONTROL
If the vehicle speed is maintained at more
than 3km/h for 2~3 seconds in the IGN1 ON state, the signal of 3 KM
Output-port shall be ON.

T1 : 2.5 ± 0.5
sec. | |