VFS (Variable Force Solenoid)
VRS Function
The spool rod in VFS is
not duty cycled like one of PWM, it minutely vibrates at the range between
the control port and exhaust port to control the hydraulic pressure. That
is, it uses the equilibrium effect between the spring force and the
magnetic force, the spring force is mechanical characteristics decided at
the stage of design and the magnetic force is controlled by TCM. This
electrical magnetic force is proportional to the current. So TCM will
control the current.
In case of VFS valve,
the electrical ‘time constant’ is considered to decide the frequency for
the current not to be fluctuated even though turns on or off the input
signal. The electrical ‘time constant’ is much more fast than one of
mechanical so the frequency of VFS is extremely higher than the
conventional PWM type.
Characteristics of Bosch
VFS:
Supply pressure :
700~1600kPa
Control pressure:
typically 600~0 kPa
Current range: typically
0~1,000 mA
Dither frequency: Up to
600 Hz
Dimension: 32 mm
protrusion reach 42 mm
The reducing pressure
will be supplied to the ‘Supply’ port of the VFS valve on the above
illustration to control the line pressure.
Reducing pressure
Function
As same as one of Alpha
or Beta automatic transaxle system, this reducing valve length can be
adjusted by rotating the screw on the picture. As you rotate the screw
toward clockwise by 90°, the reducing pressure will increase about 1.0bar.
However, the reducing pressure is used just as a ‘supply pressure’ for the
solenoid valves (except Low&Reverse, Reduction and Damper Clutch
control solen), so this may not be handled to rotate in the field service
shop. VFS is operated based on the ‘supply pressure’ and it outputs the
‘control pressure’ to control the regulator valve indirectly. While
developing the VFS system, the line pressure was used as a ‘supply
pressure’ for VFS and other solenoid valves but it has been changed into
additional ‘reducing pressure’ because the line pressure is variably
changed by VFS so the control pressure becomes unstable and some hydraulic
pressure oscillation occurred. That is why the reducing pressure has been
added in the hydraulic circuit of VFS system for both 4th and 5th speed
A/T.
The reducing pressure is
about 6.9 bar and this value does not be changed regardless of the driving
or engine load condition. Be sure that the conventional line pressure is
used for the 'supply pressure' of Low&Reverse, Reduction solenoid
because the variable line pressure is not available at reverse
range.
Hydrulic Pressure Table
Under the constant
current amount of VFS (200mA), the line pressure will become as below
table. Be sure that the following data can be achieved by specific special
facility or device to check the performance of A/T assembly (not on the
vehicle), however we can refer the maximum pressure value according to
each element.
Measuring
condition:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||