Home › Automatic Transaxle System (Automatic Transaxle) › Valve Body System › VFS(Variable Force Solenoid) Valve

Valve Body System › VFS(Variable Force Solenoid) Valve: Description and Operation (F4A51-3)

Description
Actuators
Solenoid Valve for Pressure Control
- Sensor type: Normal open 3-way
- Operating temperature : -30°C~130°C(-22°F~266°F)
- Frequency:
LR, 2ND, UD, OD: 61.27Hz (at the ATF temp. above -20°C(-4°F))
DCC: 30.64Hz
- Internal resistance:
3.0 ± 0.5 Ω (LR, 2ND, UD, OD, TCC)
4.35 ± 0.5 Ω (VFS)
- Surge voltage: 56 V (Except VFS)
(VFS)

Location

VFS Control pressure
Input Current(mA)
Control Pressure (No line pressure)
Increasing Current
Decreasing Current
MAX. (Kgf/cm²)[Kpa]
MIN. (Kgf/cm²)[Kpa]
Δ (Kgf/cm²)[Kpa]
MIN. (Kgf/cm²)[Kpa]
100
6.52[639]
5.87[575]
[64]

200
6.23[611]
5.70[559]
[52]
5.43[532]
300
5.76[564]
5.24[514]
[50]
4.49[484]
400
5.08[498]
4.59[450]
[48]
4.30[421]
500
4.24[416]
3.78[370]
[46]
3.52[345]
700
2.29[224]
1.82[178]
[46]
1.51[148]
800
1.41[138]
0.09[88]
[50]
0.58[57]
900
0.65[64]
0.14[14]
[50]
0[0]
1,000
0.24[24]
0[0]
[24]

1,100
0.24[24]
0[0]
[24]


*Test condition:
Ps : Supply Pressure (Ps=7.1 ± 0.3 KGf/cm²)
Pc : Control Pressure
Pex : Exhaust Pressure (Atmosphere pressure)
ATF : DIAMOND ATF SP-Ⅲ
ATF temperature : 30 ± 3°C (86°F)
- Coil resistance : 4.35 ± 35Ω
- Dither Frequency : 600 ± 20Hz
In case of VFS solenoid valve, the relation between Duty and oil pressure can't be expressed.