Home
›
Heating,Ventilation, Air Conditioning
›
Air conditioning System
›
A/C pressure transducer
Air conditioning System › A/C pressure transducer: Repair procedures
Inspection
1.
Measure the pressure of high pressure line by measuring voltage output between NO.1 and NO.2 terminals.
2.
Verify that the voltage value is within specification.
Voltage =
0.025 * Pressure + 0.1 [kgf/cm²]
Voltage =
0.001758 * Pressure + 0.074162 [PSIA]
3.
If the measured voltage value is not specification, replace the A/C pressure transducer.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Verify that the voltage value is within specification.
3.
Disconnect A/C pressure transducer connector (3P) (A).