Temperature control
actuator located at heater unit. It contains temp motor that changes temp
door position and potentiometer that monitors position of temp door.
Temperature control actuator regulates the temperature by the procedure as
follows. Signal from control unit adjusts position of temp door by
operating temp motor and then temperature will be regulated by the
hot/cold air ratio decided by position of temp door. In operation,
potentiometer delivers temp door position transformed into voltage value
to A/C ECU.
The ECM sets DTC B1246
if there is a short to power in the driver air mix actuator signal
harness.
Item
|
Detecting
Condition
|
Possible Cause
|
DTC
Strategy
|
|
| •
|
Open circuit in
harness |
| •
|
Short circuit in
harness. |
| •
|
Faulty DR Air Mix
actuator | |
Threshold
value
|
|
Detecting
time
|
|
Fail
safe
|
| •
|
Setting temperature :
63°F-76.1°F
fix at max. cooling
position |
| •
|
Setting temperature :
77°F-89.6°F
fix at max. heating
position | |
※ Voltage value of Air
Mix potentiometer as a function of temp door position.
Door position
|
Voltage
|
Error Detecting
Condition
|
Max.
cool
|
0.3±0.15V
|
Undervoltage : 0.08V or less
|
Max.warm
|
4.7±0.15V
|
Overvoltage : 4.9V or
more
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 3. |
Monitor the "DR AIR MIX potentiometer"
Parameter on the Scantool. While operating temp switch.

Fig1) The current data in abnormal
state
Fig2) DTC
B1246 |
| 4. |
Are the DTC B1246 present and is parameter of
"DR AIR MIX potentiometer" fixed ?
|
※ Parameter of "DR AIR MIX
potentiometer" will be fixed at d at 100%(or any value above
90%), or 0% (or any value below 10%), if there is any fault in
DR AIR MIX actuator. |
|

|
▶ Go to
"Inspection & Repair" procedure.
|
|

|
▶ Fault is
intermittent caused by poor contact in the sensor’s and/or A/C
control unit’s connector or was repaired and A/C control unit
memory was not cleared. Thoroughly
check connectors for looseness, poor connection, bending,
corrosion, contamination, deterioration, or damage. Repair or
replace as necessary and then go to "Verification of Vehicle
Repair"
procedure.
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals.
Faults can also be caused by interference from
other electrical systems, and mechanical or chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification Vehicle Repair"
procedure.
|
|

|
▶ Go to
"W/Harness Inspection"
procedure.
|
|
| Signal Circuit
Inspection |
| ■ Check for short in
harness |
| 2. |
Disconnect DR Air Mix
actuator. |
| 3. |
Measure resistance between terminal "5" and
"6" of DR Air Mix actuator.
Specification
: Approx. ∞ Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to
"Ground circuit Inspection" procedure.
|
|

|
▶ Check for
short to power harness in signal harness. Repair as necessary
and go to "Verification of Vehicle Repair"
procedure.
|
|
| Ground Circuit
inspection |
| ■ Check for open in
ground harness |
| 2. |
Disconnect DR Air Mix
actuator. |
| 3. |
Measure resistance between terminal "7" of DR
Air Mix actuator and chassis ground.
Specification
: Approx. 0 Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to
"Component Inspection " procedure.
|
|

|
▶ Check for
open in ground harness. Repair as necessary and go to
"Verification of Vehicle Repair"
procedure.
|
|
| ■ Check DR Air Mix
actuator. |
| 1. |
Check actuator motor
| (2) |
Disconnect DR Air Mix
actuator. |
| (3) |
Connect (+) terminal of battery to
terminal 3 of DR Air Mix actuator and (-) terminal to terminal
4 |
| (4) |
Verify that the temperature actuator
operates to the cool position |
| (5) |
Verify that the temperature actuator
operates to the warm position with reverse connecting.( (+) to
4 and (-) to 3)

|
| (6) |
Dose the actuator work
properly?
|

|
▶ Go
to "Check potentiometer" procedure.
|
|

|
▶
Substitute with a known-good actuator and check for
proper operation. If the problem is corrected, replace
actuator and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| 2. |
Check actuator potentiometer
| (2) |
Connect DR Air Mix
actuator. |
| (3) |
Measure voltage between terminal "6" and
"7" of DR Air Mix actuator while operating the temp
switc.
Specification : Refer
the specifications in fig3)
|

Fig3)
Door
position
|
Voltage
|
Error Detecting
Condition
|
Max. cool
|
0.3±0.15V
|
Undervoltage : 0.08V or less
|
Max.warm
|
4.7±0.15V
|
Overvoltage : 4.9V or
more
|
Fig3) Specifications : Voltage value of
Air Mix potentiometer as a function of temp door
position. |
| (4) |
Is the measured voltage within
specifications in fig3)?
|

|
▶
Check connectors for looseness, poor connection,
bending, corrosion, contamination, deterioration, or
damage. Repair or replace as necessary and then go to
"Verification of Vehicle Repair"
procedure.
|
|

|
▶
Substitute with a known-good actuator and check for
proper operation. If the problem is corrected, replace
actuator and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and selet "Diagnostic Trouble
Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on the
scantool. |
| 3. |
Are any DTCs present?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System is
performing to specification at this
time.
|
|