The mode control
actuator mounted on heater unit adjusts position of mode door by operating
Direction Motor based on signal of A/C control unit. Pressing mode select
switch makes the mode control actuator shift in order of vent→ B/L → floor
→ mix.
The ECM sets DTC B1250
if there is a short to power in the DR Direction actuator signal
harness.
Item
|
Detecting
Condition
|
Possible Cause
|
DTC
Strategy
|
|
| •
|
Open circuit in
harness |
| •
|
Short circuit in
harness. |
| •
|
Faulty DR Direction
actuator | |
Threshold
value
|
|
Detecting
time
|
|
Fail
safe
|
| •
|
Setting mode : VENT
Fix at VENT
position |
| •
|
Setting mode : Except VENT
Fix at DEF
position | |
※ Voltage value of
Direction potentiometer as a function of position of mode
switch.
Door position
|
Voltage
|
Error Detecting
Condition
|
VENT
|
0.3±0.15V
|
Undervoltage : 0.10V or less
|
DEF
|
4.7±0.15V
|
Overvoltage : 4.92V or
more
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 3. |
Monitor the "DR DIRECTION POTENTIO" parameter
on the scantool. While operating mode switch.

Fig1) The current data in abnormal
state
Fig2) DTC
B1250 |
| 4. |
Are the DTC B1250 present and is parameter of
"DR DIRECTION POTENTIO" fixed ?
|
※ Parameter of "DR DIRECTION POTENTIO"
will be fixed at 100%(or any value above 90%), or 0% (or any
value below 10%), if there is any fault in DR Direction
actuator. |
|

|
▶ Go to
"Inspection & Repair" procedure.
|
|

|
▶ Fault is
intermittent caused by poor contact in the sensor’s and/or A/C
control unit’s connector or was repaired and A/C control unit
memory was not cleared. Thoroughly
check connectors for looseness, poor connection, bending,
corrosion, contamination, deterioration, or damage. Repair or
replace as necessary and then go to "Verification of Vehicle
Repair"
procedure
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals.
Faults can also be caused by interference from
other electrical systems, and mechanical or chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification Vehicle Repair"
procedure.
|
|

|
▶ Go to
"W/Harness Inspection"
procedure.
|
|
| Signal Circuit
Inspection |
| ■ Check for short in
harness |
| 2. |
Disconnect DR Direction
potentiometer. |
| 3. |
Measure resistance between terminal or "6" and
"7"of DR Direction potentiometer
Specification
: Approx. ∞ Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to
"Ground circuit Inspection " procedure.
|
|

|
▶ Check for
short to power harness in signal harness. Repair as necessary
and go to "Verification of Vehicle Repair"
procedure.
|
|
| Ground Circuit
inspection |
| ■ Check for open in
ground harness |
| 2. |
Disconnect DR Direction
Actuator. |
| 3. |
Measure resistance between terminal "5" of DR
Direction Actuator and chassis ground.
Specification
: Approx. 0 Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to
"Component Inspection " procedure.
|
|

|
▶ Check for
open in ground harness. Repair as necessary and go to
"Verification of Vehicle Repair"
procedure.
|
|
| ■ Check DR Direction
Actuator. |
| 1. |
Check actuator motor
| (2) |
Disconnect DR Direction
Actuator. |
| (3) |
Connect (+) terminal of battery to
terminal 3 of DR Direction Actuator and (-) terminal to
terminal 4 |
| (4) |
Verify that the temperature actuator
operates to the DEF position |
| (5) |
Verify that the temperature actuator
operates to the VENT position with reverse connecting.( (+) to
4 and (-) to 3)

|
| (6) |
Dose the actuator work
properly?
|

|
▶ Go
to "Check potentiometer" procedure.
|
|

|
▶
Substitute with a known-good actuator and check for
proper operation. If the problem is corrected, replace
actuator and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| 2. |
Check actuator potentiometer
| (2) |
Connect DR Direction
Actuator. |
| (3) |
Measure voltage between terminal "5" and
"6" of DR Direction Actuator while operating the temp
switch.
Specification : Refer
the specifications in fig3)
|

Fig3)
Door
position
|
Voltage
|
Error Detecting
Condition
|
VENT
|
0.3±0.15V
|
Undervoltage : 0.10V or less
|
DEF
|
4.7±0.15V
|
Overvoltage : 4.92V or
more
|
Fig3) Specifications : Voltage value of
Direction potentiometer as a function of temp door
position. |
| (4) |
Is the measured voltage within
specifications in fig3)?
|

|
▶
Check connectors for looseness, poor connection,
bending, corrosion, contamination, deterioration, or
damage. Repair or replace as necessary and then go to
"Verification of Vehicle Repair"
procedure.
|
|

|
▶
Substitute with a known-good actuator and check for
proper operation. If the problem is corrected, replace
actuator and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and selet "Diagnostic Trouble
Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on the
scantool. |
| 3. |
Are any DTCs present?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System is
performing to specification at this
time.
|
|