The mode control
actuator mounted on heater unit adjusts position of mode door by operating
Direction Motor in accordance with signal of A/C control unit. Pressing
mode select switch makes the mode control actuator shift in order of vent→
B/L → floor → mix.
The ECM sets DTC B2409
if the direction motor dosen’t move to intended position within 40sec(The
ECM attempts to move the temp door for a 2 second duration at a frequency
of 3 times every 20 seconds before storing a DTC.)
Item
|
Detecting
Condition
|
Possible Cause
|
DTC
Strategy
|
|
| •
|
Poor connection of connected
part |
| •
|
Open circuit in
harness |
| •
|
Short circuit in
harness. |
| •
|
Faulty DR Direction
actuator |
|
Threshold
value
|
|
Detecting
time
|
|
Fail
safe
|
| •
|
Setting mode : VENT
Fix at VENT
position |
| •
|
Setting mode : Except VENT
Fix at DEF
position | |
※ Voltage value of
Direction potentiometer as a function of position of mode
switch
Door position
|
Voltage
|
Error Detecting
Condition
|
VENT
|
0.3±0.15V
|
Undervoltage : 0.10V or less
|
DEF
|
4.7±0.15V
|
Overvoltage : 4.92V or
more
|
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 3. |
Monitor the "DR DIRECTION POTENTIO" parameter
on the scantool. While operating mode switch.

Fig1) The current data in abnormal
state
Fig2) DTC
B2409 |
| 4. |
Are the DTC B2409 present and is parameter of
"DR DIRECTION POTENTIO" fixed?
|
※ There is any fault in DR Direction
Motor. If the parameter of "DR DIRECTION POTENTIO" is 10% or
less on "VENT" mode, or If the parameter is 90% or more on
"DEF" mode. |
|

|
▶ Go to
"Inspection & Repair" procedure.
|
|

|
▶ Fault is
intermittent caused by poor contact in the sensor’s and/or A/C
control unit’s connector or was repaired and A/C control unit
memory was not cleared. Thoroughly
check connectors for looseness, poor connection, bending,
corrosion, contamination, deterioration, or damage. Repair or
replace as necessary and then go to "Verification of Vehicle
Repair"
procedure.
|
|
| Terminal and Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals.
Faults can also be caused by interference from
other electrical systems, and mechanical or chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?
|

|
▶ Repair as
necessary and go to "Verification Vehicle Repair"
procedure.
|
|

|
▶ Go to
"W/Harness Inspection"
procedure.
|
|
| Signal Circuit
Inspection |
| ■ Check for open in
harness |
| 2. |
Disconnect DR Direction
Actuator. |
| 3. |
Measure resistance between terminal "3" of DR
Direction actuator and terminal "20"of A/C control
unit. |
| 4. |
Measure resistance between terminal "4" of DR
Direction actuator and terminal "19" of A/C control
unit.
Specification
: Approx. 0 Ω
|

|
| 5. |
Is the measured resistance within
specifications?
|

|
▶ Go to
"Check for short to ground in harness"
procedure.
|
|

|
▶ Check for
open in signal harness. Repair as necessary and go to
"Verification of Vehicle Repair"
procedure.
|
|
| ■ Check for short to
ground in harness |
| 2. |
Disconnect DR Direction
Actuator. |
| 3. |
Measure resistance between terminal "3,4" of
DR Direction Motor and chassis ground.
Specification
: Approx. ∞ Ω
|

|
| 4. |
Is the measured resistance within
specifications?
|

|
▶ Go to
"Component Inspection " procedure.
|
|

|
▶ Check for
short to ground in signal harness. Repair as necessary and go
to "Verification of Vehicle Repair"
procedure.
|
|
| ■ Check DR Direction
Actuator. |
| 1. |
Check actuator motor
| (2) |
Disconnect DR Direction
Actuator. |
| (3) |
Connect (+) terminal of battery to
terminal 3 of DR Direction Actuator and (-) terminal to
terminal 4 |
| (4) |
Verify that the temperature actuator
operates to the DEF position |
| (5) |
Verify that the temperature actuator
operates to the VENT position with reverse connecting.( (+) to
4 and (-) to 3)

|
| (6) |
Dose the actuator work
properly?
|

|
▶ Go
to "Check potentiometer" procedure.
|
|

|
▶
Substitute with a known-good actuator and check for
proper operation. If the problem is corrected, replace
actuator and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| 2. |
Check actuator potentiometer
| (2) |
Connect DR Direction
Actuator. |
| (3) |
Measure voltage between terminal "5" and
"6"of DR Direction Actuator while operating the temp
switch.
Specification : Refer
the specifications in fig3)
|

Fig3)
Door
position
|
Voltage
|
Error Detecting
Condition
|
VENT
|
0.3±0.15V
|
Undervoltage : 0.10V or less
|
DEF
|
4.7±0.15V
|
Overvoltage : 4.92V or
more
|
Fig3) Specifications : Voltage value of
Direction potentiometer as a function of temp door
position. |
| (4) |
Is the measured voltage within
specifications in fig3)?
|

|
▶ Go
to "Check A/C Control Unit" procedure.
|
|

|
▶
Substitute with a known-good actuator and check for
proper operation. If the problem is corrected, replace
actuator and then go to "Verification of Vehicle Repair"
procedure.
|
| |
| 2. |
Connect A/C Control
Unit. |
| 3. |
Measure voltage between terminal "19" and "20"
of A/C Control Unit while operating the temp switch.
Specification
: Approx. 12V
|

|
| 4. |
Is the measured voltage within
specifications?
|

|
▶ Check
connectors for looseness, poor connection, bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and then go to "Verification of Vehicle Repair"
procedure.
|
|

|
▶
Substitute with a known-good A/C Control Unit and check for
proper operation. If the problem is
corrected, replace A/C Control Unit and then go to
"Verification of Vehicle Repair"
procedure.
|
|
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and selet "Diagnostic Trouble
Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on the
scantool. |
| 3. |
Are any DTCs present?
|

|
▶ Go to the
applicable troubleshooting procedure.
|
|

|
▶ System is
performing to specification at this
time.
|
|