Home›Fuel System›Engine Control System›Variable Intake Solenoid (VIS) Valve
Engine Control System › Variable Intake Solenoid (VIS) Valve: Description and Operation
Function And Operation
Principle
Variable Intake Solenoid
(VIS) Valve is installed on the intake manifold and changes the effective
length of the intake passenger to improve intake efficiency under varying
engine conditions.
1.
Low/Middle Speed: VIS Valve Close → Resonation
Effect → Improving Intake
Efficiency
2.
High Speed: VIS Valve Open → Improving Intake
Inertia Effect → Improving Intake
Efficiency