Home › Heating,Ventilation, Air Conditioning › Air conditioning System › Evaporator temperature sensor

Air conditioning System › Evaporator temperature sensor: Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect evaporator temperature sensor.
3.
Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification
Evaporator core temperature
[°C(°F)]
Resistance
[KΩ]
-10(14)
43.35
-5(23)
34.48
0(32)
27.62
5(41)
22.27
10(50)
18.07
15(59)
14.75
20(68)
12.11
25(77)
10.00
30(86)
8.30
35(95)
6.93
40(104)
5.81
45(113)
4.90
50(122)
4.15

4.
If the measured resistance is within specification, substitute with a known-good evaporator temperature sensor and check for proper operation.
5.
If the problem is corrected, replace the evaporator temperature sensor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the center lower side cover (A).

3.
Disconnect the evaporator sensor connector (A).
4.
Remove the evaporator temperature sensor(B), by pulling it after rorating 90° in a counterclockwise direction.

Take care that evaporator core pins are not bent.
5.
Installation is the reverse order of removal.