| 2. |
Disconnect evaporator temperature
sensor. |
| 3. |
Using the multi-tester, Measure resistance
between terminal "1" and "2" of evaporator temperature
sensor.

Specification
Evaporator core
temperature
[°C(°F)]
|
Resistance [KΩ]
|
-10(14)
|
43.35
|
-5(23)
|
34.48
|
0(32)
|
27.62
|
5(41)
|
22.27
|
10(50)
|
18.07
|
15(59)
|
14.75
|
20(68)
|
12.11
|
25(77)
|
10.00
|
30(86)
|
8.30
|
35(95)
|
6.93
|
40(104)
|
5.81
|
45(113)
|
4.90
|
50(122)
|
4.15
|
|
| 4. |
If the measured resistance is within
specification, substitute with a known-good evaporator temperature
sensor and check for proper
operation. |
| 5. |
If the problem is corrected, replace the
evaporator temperature sensor. |
| 1. |
Disconnect the negative (-) battery
terminal. |
| 2. |
Remove the center lower side cover
(A).

|
| 3. |
Disconnect the evaporator sensor connector
(A). |
| 4. |
Remove the evaporator temperature sensor(B),
by pulling it after rorating 90° in a counterclockwise
direction.

|
Take care that evaporator core pins
are not
bent. | |
| 5. |
Installation is the reverse order of
removal. | |