| 1. |
Disconnect the canister close valve
connector (A). |
| 2. |
Disconnect the ventilation tube
quick-connector (B) and the vapor tube quick-connectors (C,
D).

|
| 3. |
Remove the installation bolts (A) and nut
(B), and then remove the canister.

|
| 1. |
Check for the following items
visually.
- Cracks or leakage of the
canister
- Loose connection, distortion, or damage of
the vapor hose/tube

A: Canister ↔ Atmosphere
B: Canister ↔ Fuel Tank
C: Canister ↔ Intake Manifold
|
Installation is the
reverse of removal.
Canister
installation bolt/nut:
3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ 4.3
lb-ft)
|